光学相干断层扫描血管成像测量的黄斑毛细血管间区与正常眼压性青光眼中心视野敏感度的关系
横断面研究纳入78只早期正常眼压性青光眼(NTG)眼、33只中晚期NTG眼和75只正常对照眼,用扫频源OCT-A量化黄斑中心3×3 mm区域血管密度、中心凹无血管区面积及10个最大毛细血管间区(ICA)。结果显示NTG眼血管密度降低、ICA增大,早期NTG眼中ICA增大与GCIPL变薄及中心视野敏感度下降相关。
要点
- NTG眼整体血管密度低于正常对照,ICA10_IncFAZ和ICA10_ExcFAZ均大于正常对照(均p≤0.016)。
- 早期NTG眼中血管密度降低和ICA增大与GCIPL厚度减少显著相关,中晚期NTG眼无此关联。
- 早期NTG眼ICA增大与中心视野敏感度相关,中晚期NTG眼则为血管密度与中心视野敏感度相关。
核心结论
- ICA增大可能是早期NTG的潜在重要疾病标志物,因其与早期NTG眼的GCIPL变薄和中心视野敏感度下降相关。
研究设计与样本
- 横断面研究纳入78只早期NTG眼、33只中晚期NTG眼和75只正常对照眼,所有参与者接受扫频源OCT-A(DRI-OCT,Topcon,东京,日本)检查。
- 使用定制MATLAB程序量化黄斑中心3×3 mm区域的血管密度、中心凹无血管区面积、包含FAZ的10个最大ICA(ICA10_IncFAZ)和不包含FAZ的10个最大ICA(ICA10_ExcFAZ)。
- 采用广义估计方程回归模型分析OCT-A血管指标与黄斑区GCIPL厚度及中心视野敏感度的关系。
主要发现
- NTG眼整体血管密度低于正常对照,ICA10_IncFAZ和ICA10_ExcFAZ均大于正常对照(均p≤0.016)。
- 多变量分析中,早期NTG眼血管密度降低(β=-0.304,p=0.006)和ICA增大(ICA10_IncFAZ β=-0.231,ICA10_ExcFAZ β=-0.259,均p≤0.042)与GCIPL厚度减少显著相关,中晚期NTG眼无此关联。
- 早期NTG眼ICA增大与中心视野敏感度相关(β=-0.310,p=0.009),中晚期NTG眼血管密度与中心视野敏感度相关(β=-0.272,p=0.038)。
关键数值与推荐
- NTG眼整体血管密度低于正常对照,ICA10_IncFAZ和ICA10_ExcFAZ大于正常对照(均p≤0.016)。
- 早期NTG眼血管密度降低(β=-0.304,p=0.006)和ICA增大(ICA10_IncFAZ β=-0.231,ICA10_ExcFAZ β=-0.259,均p≤0.042)与GCIPL厚度减少显著相关。
- 早期NTG眼ICA增大与中心视野敏感度相关(β=-0.310,p=0.009),中晚期NTG眼血管密度与中心视野敏感度相关(β=-0.272,p=0.038)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate the relationship of macular intercapillary area (ICA) with macular ganglion cell-inner plexiform layer (GCIPL) thickness and central visual field sensitivity (CVFS) in normal tension glaucoma (NTG). METHODS: Seventy-eight early NTG eyes, 33 moderate-to-severe NTG eyes and 75 normal control eyes were cross-sectional evaluated. All participants underwent swept-source optical coherence tomography angiography (OCT-A; DRI-OCT, Topcon, Tokyo, Japan). A customised MATLAB program was used to quantify macular OCT-A metrics at central 3×3 mm macular region including vascular density (VD), foveal avascular zone (FAZ) area, 10 largest ICA including FAZ area (ICA10_IncFAZ) and excluding FAZ area (ICA10_ExcFAZ). Generalised estimating equation regression models were performed to determine the relationships of OCT-A vascular metrics with GCIPL thickness in the macular region and CVFS. RESULTS: NTG eyes had lower global VD, larger ICA10_IncFAZ, and larger ICA10_ExcFAZ than normal controls (all p≤0.016). In the multivariable analyses, decreased VD (β=-0.304, p=0.006) and increased ICA (β=-0.231 for ICA10_IncFAZ and β=-0.259 for ICA10_ExcFAZ, all p≤0.042) were significantly associated with decreased GCIPL thickness in early NTG eyes but not in moderate-to-severe NTG eyes. ICA enlargement was associated with CVFS in early NTG eyes (β=-0.310, p=0.009), while VD was associated with CVFS in moderate-to-severe NTG eyes (β=-0.272, p=0.038). CONCLUSION: ICA enlargement could be a potentially important disease marker of early NTG as reflected by its association with GCIPL thinning and decrease CVFS specifically for early NTG eyes.
引用
- Shen R, Wang YM, Cheung CY, et al. Relationship between macular intercapillary area measured by optical coherence tomography angiography and central visual field sensitivity in normal tension glaucoma. Br J Ophthalmol. 2022. PMID: 35110277. doi:10.1136/bjophthalmol-2021-319923
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。