中国2型糖尿病成人眼生物测量参数与糖尿病视网膜病变发病及进展的纵向关联
该社区前瞻性队列研究于2017至2019年在广州纳入35至80岁2型糖尿病患者,测量基线屈光状态与眼生物测量参数,随访两年。结果显示,较长的眼轴长度(OR=0.76;95%CI 0.66至0.86;p<0.001)和较大的眼轴长度与角膜曲率半径比(OR=0.20;95%CI 0.07至0.55;p=0.002)与糖尿病视网膜病变发病风险降低相关,但与视力威胁性糖尿病视网膜病变发病或糖尿病视网膜病变进展无关联。
要点
- 较长眼轴长度与糖尿病视网膜病变发病风险降低相关(OR=0.76;95%CI 0.66至0.86;p<0.001)。
- 较大眼轴长度与角膜曲率半径比与糖尿病视网膜病变发病风险降低相关(OR=0.20;95%CI 0.07至0.55;p=0.002)。
- 眼轴长度和眼轴长度与角膜曲率半径比与视力威胁性糖尿病视网膜病变发病或糖尿病视网膜病变进展无关联。
核心结论
- 较长的眼轴长度和较大的眼轴长度与角膜曲率半径比是糖尿病视网膜病变发病的保护因素。
- 这些参数可能被纳入未来的糖尿病视网膜病变风险预测模型,以个体化糖尿病视网膜病变筛查频率和预防措施。
研究设计与样本
- 该研究为社区前瞻性队列研究,于2017至2019年在中国广州招募35至80岁2型糖尿病患者。
- 基线测量屈光状态和眼生物测量参数,包括眼轴长度、眼轴长度与角膜曲率半径比、角膜曲率、晶状体厚度、前房深度、晶状体屈光力和角膜直径。
- 共1370名参与者(平均年龄64.3±8.1岁)完成连续两年随访。
主要发现
- 随访期间,基线无糖尿病视网膜病变的1195名参与者中342名(28.6%)发生糖尿病视网膜病变。
- 基线有糖尿病视网膜病变的175名参与者中15名(8.57%)出现糖尿病视网膜病变进展,其中11名进展为视力威胁性糖尿病视网膜病变。
- 多因素调整后,较长眼轴长度与糖尿病视网膜病变发病风险降低相关(OR=0.76;95%CI 0.66至0.86;p<0.001)。
- 较大眼轴长度与角膜曲率半径比与糖尿病视网膜病变发病风险降低相关(OR=0.20;95%CI 0.07至0.55;p=0.002)。
- 眼轴长度和眼轴长度与角膜曲率半径比与视力威胁性糖尿病视网膜病变发病或糖尿病视网膜病变进展无关联。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To investigate the associations of ocular biometric parameters with incident diabetic retinopathy (DR), incident vision-threatening DR (VTDR) and DR progression. METHODS: This community-based prospective cohort study recruited participants with type 2 diabetes aged 35-80 years from 2017 to 2019 in Guangzhou, China. Refractive error and ocular biometric parameters were measured at baseline, including axial length (AL), axial length-to-corneal radius (AL/CR) ratio, corneal curvature (CC), lens thickness (LT), anterior chamber depth (ACD), lens power and corneal diameter (CD). RESULTS: A total of 1370 participants with a mean age of 64.3±8.1 years were followed up for two consecutive years. During the follow-up period, 342 out of 1195 (28.6%) participants without DR at baseline had incident DR, 15 out of 175 (8.57%) participants with baseline DR had DR progression and 11 of them progressed to VTDR. After multiple adjustments, a longer AL (OR=0.76; 95% CI, 0.66 to 0.86; p<0.001) and a larger AL/CR ratio (OR=0.20; 95% CI, 0.07 to 0.55; p=0.002) were associated with significantly reduced risks of incident DR but were not associated with incident VTDR or DR progression. Refractive status and other ocular biometric parameters investigated, including ACD, CC, CD, lens power and LT were not associated with any of the DR outcomes (all p>0.05). CONCLUSIONS: A longer AL and a larger AL/CR ratio are protective against incident DR. These parameters may be incorporated into future DR risk prediction models to individualise the frequency of DR screening and prevention measures.
引用
- Wang W, Chen Y, Xiong K, et al. Longitudinal associations of ocular biometric parameters with onset and progression of diabetic retinopathy in Chinese adults with type 2 diabetes mellitus. Br J Ophthalmol. 2022. PMID: 35115303. doi:10.1136/bjophthalmol-2021-320046
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。