OCTA衍生血管骨架密度与通量及其与全身健康决定因素的关联
本研究为横断面研究,从非洲裔美国人眼病研究中招募受试者,使用扫频源OCTA成像黄斑中央3×3 mm区域,评估视网膜毛细血管灌注的血管骨架密度(VSD)和通量。结果发现通量与红细胞压积正相关,与年龄、收缩压和糖尿病状态负相关;VSD与年龄和视网膜病变负相关。通量可提供区别于骨架密度测量的视网膜灌注信息,适用于检测无视网膜病变临床征象时的亚临床灌注变化。
要点
- 通量与红细胞压积正相关(P=0.02),与年龄(P<0.001)、收缩压(P=0.04)和糖尿病状态(P=0.02)负相关。
- VSD与年龄(P<0.001)和视网膜病变(P=0.02)负相关,与红细胞压积无显著相关(P=0.85)。
- 红细胞压积降低1%与通量的变化幅度相当于约1.24年衰老所对应的变化。
核心结论
- 扫频源OCTA衍生的通量提供区别于骨架密度测量的视网膜灌注额外信息,适用于检测无视网膜病变临床征象时的亚临床灌注变化。
研究设计与样本
- 横断面研究,受试者招募自非洲裔美国人眼病研究(African American Eye Disease Study),共纳入83名受试者的154只眼。
- 使用商用扫频源OCTA设备成像黄斑中央3×3 mm区域,评估视网膜毛细血管灌注的血管骨架密度(VSD)和通量。
- 采用多变量广义线性混合效应模型评估OCTA衍生指标与全身健康决定因素的关联。
主要发现
- VSD均值0.148±0.009,通量均值0.156±0.016。
- 在包含年龄、收缩压、糖尿病状态、红细胞压积和视网膜病变存在与否作为协变量的模型中,VSD与年龄(P<0.001)和视网膜病变(P=0.02)呈负相关,与红细胞压积(P=0.85)或其他因素无显著相关。
- 通量与红细胞压积呈正相关(P=0.02),与年龄(P<0.001)、收缩压(P=0.04)和糖尿病状态(P=0.02)呈负相关。
- 红细胞压积降低1%与通量的变化幅度相当于约1.24年衰老所对应的变化。
- 信号强度与通量相关(P<0.001),但与VSD无显著相关(P=0.51)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To examine the associations of optical coherence tomography angiography (OCTA)-derived retinal capillary flux with systemic determinants of health. METHODS: This is a cross-sectional study of subjects recruited from the African American Eye Disease Study. A commercially available swept-source (SS)-OCTA device was used to image the central 3 × 3 mm macular region. Retinal capillary perfusion was assessed using vessel skeleton density (VSD) and flux. Flux approximates the number of red blood cells moving through vessel segments and is a novel metric, whereas VSD is a previously validated measure commonly used to quantify capillary density. The associations of OCTA derived measures with systemic determinants of health were evaluated using multivariate generalized linear mixed-effects models. RESULTS: A total of 154 eyes from 83 participants were enrolled. Mean VSD and flux were 0.148 ± 0.009 and 0.156 ± 0.016, respectively. In a model containing age, systolic blood pressure, diabetes status, hematocrit, and presence of retinopathy as covariates, there was a negative correlation between VSD and age (P < 0.001) and retinopathy (P = 0.02), but not with hematocrit (P = 0.85) or other factors. There was a positive correlation between flux and hematocrit (P = 0.02), as well as a negative correlation for flux with age (P < 0.001), systolic blood pressure (P = 0.04), and diabetes status (P = 0.02). A 1% decrease in hematocrit was associated with the same magnitude change in flux as ∼1.24 years of aging. Signal strength was associated with flux (P < 0.001), but not VSD (P = 0.51). CONCLUSIONS: SS-OCTA derived flux provides additional information about retinal perfusion distinct from that obtained with skeleton density-based measures. Flux is appropriate for detecting subclinical changes in perfusion in the absence of clinical retinopathy.
引用
- Kushner-Lenhoff S, Li Y, Zhang Q, et al. OCTA Derived Vessel Skeleton Density Versus Flux and Their Associations With Systemic Determinants of Health. Invest Ophthalmol Vis Sci. 2022. PMID: 35142788. doi:10.1167/iovs.63.2.19
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。