采用扫频源光学相干断层扫描血管成像评估脉络膜毛细血管灌注与糖尿病视网膜病变严重程度的关系
在广州市招募的2型糖尿病患者中,按ETDRS标准对糖尿病视网膜病变(DR)分级,用扫频源光学相干断层扫描血管成像(SS-OCTA)量化脉络膜毛细血管血流灌注(血流缺损密度、数量和大小),发现DR患者血流缺损密度显著高于无DR组,且随DR严重程度增加而升高,加入血流缺损密度可改善DR判别性能。
要点
- DR患者脉络膜毛细血管血流缺损密度显著高于无DR组,且随DR严重程度增加而升高。
- 血流缺损数量和大小也与更严重的DR程度相关(均p<0.05)。
核心结论
- 采用SS-OCTA量化的血流缺损密度、数量和大小与DR严重程度独立相关,黄斑区脉络膜毛细血管灌注指标可能是DR变化的敏感生物标志物。
研究设计与样本
- 研究招募广州市2型糖尿病患者,按ETDRS标准化的七视野彩色视网膜图像对DR进行分级,采用SS-OCTA量化脉络膜毛细血管灌注,用多变量线性回归评估血流缺损指标与DR严重程度的相关性,最终分析纳入1692例患者(眼)。
主要发现
- 校正混杂因素后,与无DR组相比,轻度非增殖性DR(NPDR)患者血流缺损密度差异为1.61%(95%CI 1.04至2.18;p<0.001),中度NPDR患者差异为2.23%(95%CI 1.76至2.70;p<0.001),重度DR患者差异为3.31%(95%CI 2.27至4.36;p<0.001)。
- 更高的血流缺损数量和大小也与更严重的DR程度相关(均p<0.05)。
临床怎么用
- 原文结论认为黄斑区脉络膜毛细血管灌注指标可能是DR变化的敏感生物标志物。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: To investigate the relationship between choriocapillaris (CC) blood perfusion and the severity of diabetic retinopathy (DR) using swept-source optical coherence tomography angiography (SS-OCTA). METHODS: Type 2 diabetes mellitus in the Guangzhou was recruited. DR was graded according to the standardised seven-field colour retinal images adhering to the ETDRS scale. CC perfusion was quantified by evaluating the flow deficit (FD) density, FD number and FD size using SS-OCTA. Multivariable linear regressions were used to evaluate the correlation between CC FD metrics and DR severity. RESULTS: A total of 1692 patients (eyes) were included in the final analysis. Participants with DR had a significantly higher FD density than the NDR group, with the differences of 1.61% (95% CI 1.04 to 2.18; p<0.001) among mild non-proliferative DR (NPDR) patients, 2.23% (95% CI 1.76 to 2.70; p<0.001) among moderate NPDR patients and 3.31% (95% CI 2.27 to 4.36; p<0.001) among severe DR than NDR patients after adjusting for confounding factors. Similarly, the higher FD number and size were also correlated with severer degree of DR (all p<0.05). Furthermore, the addition of FD density to conventional risk factors significantly improved the performance for discriminating DR from NDR patients (AUC 0. 829, 95% CI 0. 804 to 0. 855; p<0.001). CONCLUSION: Quantitative FD density, number and size assessed by using SS-OCTA were independently correlated with the severity of DR. The assessment of the CC perfusion metrics in the macula may be a sensitive biomarker of DR changes.
引用
- Wang W, Guo X, Chen Y, et al. Choriocapillaris perfusion assessed using swept source optical coherence tomographic angiography and the severity of diabetic retinopathy. Br J Ophthalmol. 2022. PMID: 35115302. doi:10.1136/bjophthalmol-2021-320163
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。