低能量飞秒激光辅助白内障手术后前列腺素释放:未用抗炎药预处理
本研究在维也纳医科大学眼科对70例双侧年龄相关性白内障患者(140眼)行同天双侧低脉冲能量飞秒激光辅助白内障手术(LCS),随机一眼先行前囊切开(Caps-First)另眼先行晶状体碎核(Frag-First),未用非甾体抗炎药(NSAID)预处理。LCS后5分钟前房穿刺测前列腺素E2(PGE-2),并记录瞳孔直径。结果显示两组的PGE-2浓度和瞳孔直径均无显著差异,低能量飞秒激光预处理未增加PGE-2水平,也未观察到瞳孔缩小。
要点
- 低能量飞秒激光预处理后前房PGE-2浓度未升高,且与先行囊切开或碎核无关。
- Caps-First组与Frag-First组PGE-2浓度分别为42.0 ± 63.7 pg/mL与71.8 ± 160.7 pg/mL(P = .186)。
- 预处理前后瞳孔直径均为7.6 ± 0.8 mm(P = .871),未观察到瞳孔缩小。
核心结论
- 低能量飞秒激光预处理在未用NSAID预处理的情况下未增加PGE-2水平,且与先行囊切开或碎核无关,也未观察到瞳孔缩小。
研究设计与样本
- 前瞻性、随机、对侧眼对照比较研究,在维也纳医科大学眼科开展,纳入70例双侧年龄相关性白内障患者的140眼。
主要发现
- Caps-First组平均PGE-2浓度为42.0 ± 63.7 pg/mL,Frag-First组为71.8 ± 160.7 pg/mL(P = .186)。
- 预处理前平均瞳孔直径为7.6 ± 0.8 mm,预处理后为7.6 ± 0.8 mm(P = .871)。
- 平均PGE-2浓度和瞳孔直径在时间点或组间均无显著差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To compare prostaglandin E2 (PGE-2) levels in the aqueous and pupil diameter in patients undergoing low-pulse energy femtosecond laser-assisted cataract surgery (LCS) without non-steroidal anti-inflammatory (NSAID) pretreatment with either fragmentation or capsulotomy performed first. DESIGN: Prospective, randomized, fellow-eye controlled comparison. METHODS: This study was undertaken at the Department of Ophthalmology, Medical University of Vienna. The population consisted of 140 eyes of 70 patients with bilateral age-related cataract. Bilateral same-day LCS with either anterior capsulotomy before lens fragmentation (Caps-First) in one eye or vice versa (Frag-First) in a random sequence were performed. Aqueous was tapped 5 minutes after LCS and PGE-2 concentration was analyzed. Pupil diameters were recorded immediately before and after femtosecond laser pretreatment. The main outcome measure was PGE-2 concentrations in picograms/milliliter and pupil diameter in millimeters. RESULTS: Mean PGE-2 concentrations were 42.0 ± 63.7 pg/mL in the Caps-First group versus 71.8 ± 160.7 pg/mL with the Frag-First group (P = .186). Mean pupil diameters before and after pretreatment were 7.6 ± 0.8 mm and 7.6 ± 0.8 mm, respectively (P = .871). Mean PGE-2 concentrations and pupil diameters did not show any significant difference between time points or groups. CONCLUSIONS: Low-energy femtosecond laser pretreatment did not increase PGE-2 levels in the absence of NSAID pretreatment. This was independent of whether capsulotomy or fragmentation was performed first. Moreover, no pupillary miosis was observed.
引用
- Schwarzenbacher L, Schartmüller D, Leydolt C, et al. Prostaglandin Release After Low-Energy Femtosecond Laser-Assisted Cataract Surgery Without Anti-Inflammatory Drug Premedication. Am J Ophthalmol. 2022. PMID: 35033540. doi:10.1016/j.ajo.2022.01.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。