原发性开角型青光眼中黄斑神经节细胞复合体厚度与脉络膜微血管缺失的关系
基于诊断创新青光眼研究,纳入随访至少1.5年、至少3次就诊的原发性开角型青光眼患者,用OCT-A在基线检测深层微血管缺失(MvD),比较有MvD眼与无MvD眼的黄斑神经节细胞复合体(GCC)变薄速率。结果显示有MvD眼整体GCC变薄显著更快,MvD存在、面积及角周径均与更快的变薄速率独立相关。
要点
- 有MvD眼整体GCC变薄速率较无MvD眼快,平均差异为-0.50 µm/年。
- 36只MvD眼中30只MvD位于颞下区域。
- MvD存在、面积及角周径均与更快的GCC变薄速率独立相关。
核心结论
- 在原发性开角型青光眼眼中,存在MvD的眼GCC变薄更快。
- OCT-A图像中检测MvD可帮助临床医生识别中央黄斑变薄和青光眼进展风险更高的患者,这些患者可能需要更密集的管理。
研究设计与样本
- 研究纳入诊断创新青光眼研究中随访至少1.5年且至少3次就诊的原发性开角型青光眼患者。
- 基线通过OCT-A检测MvD,在脉络膜血管密度正面图和水平B扫描上评估MvD的面积和角周径。
- 采用线性混合效应模型比较有MvD眼与无MvD眼的整体及半球GCC变薄速率。
主要发现
- 63例患者的36只MvD眼和37只无MvD眼被随访,平均随访3.3年。
- 36只MvD眼中30只MvD位于颞下区域。
- 两组基线视野平均偏差相似(p=0.128)。
- 有MvD眼整体GCC变薄显著快于无MvD眼,平均差异为-0.50(95%CI -0.83至-0.17)µm/年,p=0.003。
- MvD存在、MvD面积和MvD角周径均与更快的变薄速率独立相关(分别为p=0.002、p=0.031和p=0.013)。
临床怎么用
- 作者认为,在OCT-A图像中检测MvD可帮助临床医生识别中央黄斑变薄和青光眼进展风险更高的患者,这些患者可能需要更密集的管理。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND/AIMS: To investigate the rate of ganglion cell complex (GCC) thinning in primary open-angle glaucoma (POAG) patients with and without deep-layer microvasculature drop-out (MvD). METHODS: POAG patients who had at least 1.5 years of follow-up and a minimum of three visits were included from the Diagnostic Innovations in Glaucoma Study. MvD was detected at baseline by optical coherence tomography angiography (OCT-A). Area and angular circumference of MvD were evaluated on en face choroidal vessel density images and horizontal B-scans. Rates of global and hemisphere GCC thinning were compared in MvD and non-MvD eyes using linear mixed-effects models. RESULTS: Thirty-six eyes with MvD and 37 eyes without MvD of 63 patients were followed for a mean of 3.3 years. In 30 out of 36 eyes, MvD was localised in the inferotemporal region. While mean baseline visual field mean deviation was similar between the two groups (p=0.128), global GCC thinning was significantly faster in eyes with MvD than in those without MvD (mean differences: -0.50 (95% CI -0.83 to -0.17) µm/year; p=0.003)). Presence of MvD, area and angular circumference of MvD were independently associated with a faster rate of thinning (p=0.002, p=0.031 and p=0.013, respectively). CONCLUSION: In POAG eyes, GCC thinning is faster in eyes with MvD. Detection of MvD in OCT-A images can assist clinicians to identify patients who are at higher risk for central macula thinning and glaucomatous progression and may require more intensive management.
引用
- Micheletti E, Moghimi S, El-Nimri N, et al. Relationship of macular ganglion cell complex thickness to choroidal microvasculature drop-out in primary open-angle glaucoma. Br J Ophthalmol. 2022. PMID: 35027356. doi:10.1136/bjophthalmol-2021-320621
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。