三维平视显示系统与标准手术显微镜用于玻璃体切除术的系统评价与Meta分析
该系统评价与Meta分析纳入15项研究共2889只眼,比较三维平视显示系统(3D HUD)与标准手术显微镜(SOM)行玻璃体切除术的效果。结果显示3D HUD手术时间较长(加权均数差1.48,95%CI 0.13-2.82),但眼内照明水平较低(加权均数差-16.04,95%CI -18.33至-13.75),术后最佳矫正视力、术中并发症、孔源性视网膜脱离再附着率及黄斑裂孔闭合率均无显著差异。作者认为3D HUD可提供更低的视网膜光毒性,但手术时间较长,手术结果与并发症与SOM相当。
要点
- 3D HUD玻璃体切除术手术时间较SOM长(加权均数差1.48,95%CI 0.13-2.82)。
- 3D HUD所需眼内照明水平低于SOM(加权均数差-16.04,95%CI -18.33至-13.75)。
- 术后最佳矫正视力、术中并发症、孔源性视网膜脱离再附着率及黄斑裂孔闭合率两组无显著差异。
核心结论
- 作者认为3D HUD可提供更低的视网膜光毒性,但手术时间较长,玻璃体切除术的手术结果与并发症在3D HUD与SOM间相当。
研究设计与样本
- 系统评价与Meta分析,检索PubMed、Cochrane Library和Embase数据库,纳入比较3D HUD与SOM行玻璃体切除术治疗视网膜疾病的研究(PROSPERO方案CRD42021265827)。
- 共纳入15项研究、2889只眼。
主要发现
- 与SOM相比,3D HUD玻璃体切除术手术时间较长(加权均数差1.48,95%CI 0.13-2.82)。
- 3D HUD所需眼内照明水平低于SOM(加权均数差-16.04,95%CI -18.33至-13.75)。
- 术后最佳矫正视力、术中并发症、孔源性视网膜脱离再附着率及黄斑裂孔闭合率两组无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the effects of vitrectomy with three-dimensional head-up display (3D HUD) versus standard operating microscopy (SOM) for retinal diseases. METHODS: The PubMed, Cochrane Library, and Embase databases were comprehensively searched to identify studies that compared 3D HUD versus SOM in vitrectomy for retinal diseases (PROSPERO protocol CRD42021265827). The primary outcomes are duration of surgical time, postoperative best-corrected visual acuity, endoillumination levels, and intraoperative complications. The secondary outcomes are reattachment rate of rhegmatogenous retinal detachment, macular hole closure rate, and the like. RESULTS: Fifteen studies of 2,889 eyes were included. Compared with SOM, 3D HUD vitrectomy took a longer surgical time (weighted mean difference = 1.48; 95% confidence interval, 0.13-2.82), but it needed lower endoillumination levels (weighted mean difference = -16.04, 95% confidence interval, -18.33 to -13.75) than SOM. There were no significant differences in the postoperative best-corrected visual acuity, intraoperative complications, reattachment rate of rhegmatogenous retinal detachment, or closure rate of macular hole. CONCLUSION: Our results suggested that 3D HUD provides lower retinal illumine toxicities but with a longer surgical time. The surgical results and complications of vitrectomy were equally comparable for 3D HUD and SOM.
引用
- Wang Y, Zhao X, Zhang W, et al. THREE-DIMENSIONAL HEAD-UP DISPLAY VERSUS STANDARD OPERATING MICROSCOPE FOR VITRECTOMY SURGERY: A Systematic Review and Meta-analysis. Retina. 2022. PMID: 35067608. doi:10.1097/IAE.0000000000003414
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。