文献速递青光眼眼底病与葡萄膜炎

机器学习利用眼底和视网膜光学相干断层扫描图像检测青光眼的性能:一项Meta分析

Performances of Machine Learning in Detecting Glaucoma Using Fundus and Retinal Optical Coherence Tomography Images: A Meta-Analysis.
PubMed 文献 · Am J Ophthalmol · 2021-12-21

该Meta分析检索了PubMed和EMBASE(2021年8月11日),纳入105项研究,评估机器学习利用眼底和视网膜OCT图像检测青光眼的性能。总体合并敏感度和特异度分别为眼底0.92和0.93、OCT 0.90和0.91,AUC分别为0.97和0.96。作者认为机器学习检测青光眼性能与专家相当,具有临床应用前景,但需前瞻性研究评估真实世界效用。

要点

  • 机器学习利用眼底图像检测青光眼的合并敏感度0.92、特异度0.93、AUC 0.97。
  • 机器学习利用OCT图像检测青光眼的合并敏感度0.90、特异度0.91、AUC 0.96。
  • OCT外部测试结果稳健性较低(AUC=0.87),作者认为需前瞻性研究评估真实世界效用。

核心结论

  • 机器学习检测青光眼的性能与专家相当,具有临床应用前景。
  • 作者认为需要未来前瞻性研究以更好地评估其真实世界效用。

研究设计与样本

  • Meta分析,检索PubMed和EMBASE(检索日期2021年8月11日)。
  • 共纳入105项研究,其中73项(69.5%)使用眼底图像、30项(28.6%)使用OCT、2项(1.9%)同时使用两种图像类型测试机器学习。
  • 眼底测试数据总量为197,174,OCT测试数据总量为16,039。
  • 采用双变量随机效应模型合并诊断敏感度、特异度和AUC。

主要发现

  • 眼底图像:合并敏感度0.92(95%CI 0.91-0.93)、特异度0.93(95%CI 0.91-0.94)、AUC 0.97(95%CI 0.95-0.98)。
  • OCT图像:合并敏感度0.90(95%CI 0.86-0.92)、特异度0.91(95%CI 0.89-0.92)、AUC 0.96(95%CI 0.93-0.97)。
  • 机器学习使用全部数据和外部数据在眼底图像上表现相似,而OCT的外部测试结果稳健性较低(AUC=0.87)。
  • 支持向量机性能最高(合并敏感度、特异度、AUC范围分别为0.92-0.96、0.95-0.97、0.96-0.99),神经网络及其他方法结果仍良好(合并敏感度、特异度、AUC范围分别为0.88-0.93、0.90-0.93、0.95-0.97)。
  • 基于数据集类型分析,机器学习在临床数据集上表现一致(眼底AUC=0.98 [95%CI 0.97-0.99],OCT AUC=0.95 [95%CI 0.93-0.97])。

关键数值与推荐

  • 眼底图像机器学习检测青光眼:合并敏感度0.92(95%CI 0.91-0.93)、特异度0.93(95%CI 0.91-0.94)、AUC 0.97(95%CI 0.95-0.98)。
  • OCT图像机器学习检测青光眼:合并敏感度0.90(95%CI 0.86-0.92)、特异度0.91(95%CI 0.89-0.92)、AUC 0.96(95%CI 0.93-0.97)。
  • OCT外部测试AUC=0.87。
  • 支持向量机合并敏感度、特异度、AUC范围分别为0.92-0.96、0.95-0.97、0.96-0.99。
  • 神经网络及其他方法合并敏感度、特异度、AUC范围分别为0.88-0.93、0.90-0.93、0.95-0.97。

临床怎么用

  • 作者认为机器学习检测青光眼性能与专家相当,具有临床应用前景。
  • 作者认为需要未来前瞻性研究以更好地评估其真实世界效用。

局限性

  • 作者认为需要未来前瞻性研究以更好地评估其真实世界效用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the performance of machine learning (ML) in detecting glaucoma using fundus and retinal optical coherence tomography (OCT) images. DESIGN: Meta-analysis. METHODS: PubMed and EMBASE were searched on August 11, 2021. A bivariate random-effects model was used to pool ML's diagnostic sensitivity, specificity, and area under the curve (AUC). Subgroup analyses were performed based on ML classifier categories and dataset types. RESULTS: One hundred and five studies (3.3%) were retrieved. Seventy-three (69.5%), 30 (28.6%), and 2 (1.9%) studies tested ML using fundus, OCT, and both image types, respectively. Total testing data numbers were 197,174 for fundus and 16,039 for OCT. Overall, ML showed excellent performances for both fundus (pooled sensitivity = 0.92 [95% CI, 0.91-0.93]; specificity = 0.93 [95% CI, 0.91-0.94]; and AUC = 0.97 [95% CI, 0.95-0.98]) and OCT (pooled sensitivity = 0.90 [95% CI, 0.86-0.92]; specificity = 0.91 [95% CI, 0.89-0.92]; and AUC = 0.96 [95% CI, 0.93-0.97]). ML performed similarly using all data and external data for fundus and the external test result of OCT was less robust (AUC = 0.87). When comparing different classifier categories, although support vector machine showed the highest performance (pooled sensitivity, specificity, and AUC ranges, 0.92-0.96, 0.95-0.97, and 0.96-0.99, respectively), results by neural network and others were still good (pooled sensitivity, specificity, and AUC ranges, 0.88-0.93, 0.90-0.93, 0.95-0.97, respectively). When analyzed based on dataset types, ML demonstrated consistent performances on clinical datasets (fundus AUC = 0.98 [95% CI, 0.97-0.99] and OCT AUC = 0.95 [95% 0.93-0.97]). CONCLUSIONS: Performance of ML in detecting glaucoma compares favorably to that of experts and is promising for clinical application. Future prospective studies are needed to better evaluate its real-world utility.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Wu JH, Nishida T, Weinreb RN, et al. Performances of Machine Learning in Detecting Glaucoma Using Fundus and Retinal Optical Coherence Tomography Images: A Meta-Analysis. Am J Ophthalmol. 2021. PMID: 34942113. doi:10.1016/j.ajo.2021.12.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。