文献速递青光眼

健康眼与稳定期青光眼眼用光学相干断层扫描血管成像的长期可重复性

Long-term reproducibility of optical coherence tomography angiography in healthy and stable glaucomatous eyes.
PubMed 文献 · Br J Ophthalmol · 2021-12-21

本研究纳入88只眼(15只健康眼、38只可疑青光眼、35只非进展性原发性开角型青光眼),在1-1.5年内至少三次同日进行OCTA和OCT成像,评估视盘和黄斑血管参数及厚度参数的长期可重复性。结果显示OCTA血管参数的组内相关系数(ICC)低于OCT厚度参数,黄斑旁中心凹血管密度(pfVD)ICC为0.823,视盘环周毛细血管密度(cpCD)为0.871,而黄斑旁中心凹神经节细胞复合体(pfGCC)为0.995,视盘环周视网膜神经纤维层(cpRNFL)为0.975。结论认为OCTA血管参数具有良好长期可重复性,但低于OCT厚度参数,系列OCTA图像评估变化时需考虑此点。

要点

  • OCTA黄斑旁中心凹血管密度ICC为0.823,视盘环周毛细血管密度ICC为0.871。
  • OCT黄斑旁中心凹神经节细胞复合体ICC为0.995,视盘环周视网膜神经纤维层ICC为0.975。
  • OCTA血管参数长期可重复性良好但低于OCT厚度参数,系列评估变化时需考虑。

核心结论

  • OCTA测量的黄斑和视盘血管参数具有良好长期可重复性,支持将该仪器用于纵向分析。
  • OCTA长期可重复性低于OCT测量的厚度可重复性,系列OCTA图像评估变化时需考虑此点。

研究设计与样本

  • 纳入88只眼(15只健康眼、38只可疑青光眼、35只非进展性原发性开角型青光眼)来自68名受试者,在1-1.5年内至少三次同日进行OCTA和OCT成像(Angiovue;Optovue,美国加利福尼亚州弗里蒙特)。
  • 采用随机效应方差分析模型估计组内相关系数(ICC)和长期变异性。

主要发现

  • OCTA参数ICC:黄斑旁中心凹血管密度(pfVD)0.823(95%CI 0.736至0.888),视盘环周毛细血管密度(cpCD)0.871(95%CI 0.818至0.912)。
  • OCT参数ICC:黄斑旁中心凹神经节细胞复合体(pfGCC)0.995(95%CI 0.993至0.997),视盘环周视网膜神经纤维层(cpRNFL)0.975(95%CI 0.964至0.984)。
  • 个体内重测标准差:pfVD为1.17%,cpCD为1.22%,pfGCC为0.57 µm,cpRNFL为1.22 µm。
  • 年龄较大和信号强度指数较低与血管密度长期变异性降低相关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND/AIMS: To assess and compare long-term reproducibility of optic nerve head (ONH) and macula optical coherence tomography angiography (OCTA) vascular parameters and optical coherence tomography (OCT) thickness parameters in stable primary open-angle glaucoma (POAG), glaucoma suspect and healthy eyes. METHODS: Eighty-eight eyes (15 healthy, 38 glaucoma suspect and 35 non-progressing POAG) of 68 subjects who had at least three visits within 1-1.5 years with OCTA and OCT imaging (Angiovue; Optovue, Fremont, California, USA) on the same day were included. A series of vascular and thickness parameters were measured including macular parafoveal vessel density (pfVD), ONH circumpapillary capillary density (cpCD), macular parafoveal ganglion cell complex (pfGCC) and ONH circumpapillary retinal nerve fibre layer (cpRNFL). A random effects analysis of variance model was used to estimate intraclass correlation (ICC) coefficients and long-term variability estimates. RESULTS: ICC was lower for OCTA (pfVD 0.823 (95% CI 0.736 to 0.888) and cpCD 0.871 (0.818 to 0.912)) compared with OCT (pfGCC 0.995 (0.993 to 0.997) and cpRNFL 0.975 (0.964 to 0.984)). Within-subject test-retest SD was 1.17% and 1.22% for pfVD and cpCD, and 0.57 and 1.22 µm for pfGCC and cpRNFL. Older age and lower signal strength index were associated with decreasing long-term variability of vessel densities. CONCLUSIONS: OCTA-measured macula and ONH vascular parameters have good long-term reproducibility, supporting the use of this instrument for longitudinal analysis. OCTA long-term reproducibility is less than OCT-measured thickness reproducibility. This needs to be taken into consideration when serial OCTA images are evaluated for change. TRIAL REGISTRATION NUMBER: NCT00221897.

来源:Br J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Nishida T, Moghimi S, Hou H, et al. Long-term reproducibility of optical coherence tomography angiography in healthy and stable glaucomatous eyes. Br J Ophthalmol. 2021. PMID: 34933897. doi:10.1136/bjophthalmol-2021-320034

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。