光学微血管造影与原发性开角型青光眼进行性视网膜神经节细胞-内丛状层丢失的关系
前瞻性病例系列研究纳入38例原发性开角型青光眼患者的63只眼,分析106个基线轻中度功能损害半侧视野,评估基线光学微血管造影(OMAG)测量与视网膜神经节细胞-内丛状层(GCIPL)厚度年变化率的关系。多变量混合模型显示,较低的视乳头周围灌注密度(系数0.04,P=0.01)和血管密度(系数0.09,P=0.05)与更快的GCIPL丢失速率显著相关。
要点
- 基线视乳头周围灌注密度较低与GCIPL丢失速率更快显著相关(系数0.04,P=0.01)。
- 基线视乳头周围血管密度较低与GCIPL丢失速率更快显著相关(系数0.09,P=0.05)。
- 黄斑区OMAG测量与GCIPL丢失速率的关系在原文中未报告。
核心结论
- 基线视乳头周围OMAG测量值较低与轻中度原发性开角型青光眼患者更快的GCIPL丢失速率显著相关。
研究设计与样本
- 前瞻性病例系列研究,纳入38例原发性开角型青光眼患者的63只眼,随访≥2年且至少完成3次光学相干断层扫描(OCT)检查。
- 仅纳入基线轻中度功能损害的106个半侧视野进行分析,基线时进行OMAG成像。
主要发现
- 分析半侧视野基线平均偏差为-5.2±2.8 dB,象限视网膜神经纤维层厚度为94.5±20.0 µm,扇区GCIPL厚度为72.4±8.7 µm。
- 象限视乳头周围灌注密度为43.1%±7.0%,血管密度为17.0±2.6 mm/mm²;黄斑区灌注密度为37.2%±6.9%,血管密度为15.1±2.6 mm/mm²。
- 扇区GCIPL年变化率为-0.97±0.15 µm/年。
- 多变量混合模型显示,较低的视乳头周围灌注密度(系数0.04,P=0.01)和血管密度(系数0.09,P=0.05)与更快的GCIPL丢失速率显著相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the association between optical microangiography (OMAG) measurements and progressive ganglion cell-inner plexiform layer (GCIPL) loss in patients with primary open-angle glaucoma (POAG). DESIGN: Prospective case series. METHODS: Sixty-three eyes of 38 patients with POAG were studied for ≥2 years and with ≥ 3 optical coherence tomography examinations. Only those hemifields with mild to moderate functional damage at baseline (106 hemifields) were included in the analysis. OMAG imaging was performed at the baseline visit. The effects of clinical parameters (age, gender, central corneal thickness, presence of disc hemorrhage, and mean and fluctuation of intraocular pressure), baseline mean deviation, retinal nerve fiber layer, and GCIPL thickness and baseline OMAG measurements (peripapillary and macular perfusion density [PD] and vessel density [VD]) on the rate of change of GCIPL thickness were evaluated using linear mixed models. RESULTS: Average (± standard deviation) mean deviation, quadrant retinal nerve fiber layer, and sector GCIPL thickness of the analyzed hemifields respectively at baseline were -5.2 ± 2.8 dB, 94.5 ± 20.0 µm, and 72.4 ± 8.7 µm, respectively. Peripapillary PD and VD in the quadrant were 43.1% ± 7.0% and 17.0 ± 2.6 mm/mm2, respectively. Macular PD and VD in the quadrant were 37.2% ± 6.9% and 15.1 ± 2.6 mm/mm2, respectively. Rate of sector GCIPL change was -0.97 ± 0.15 µm per year. Multivariate mixed models showed that lower peripapillary PD (coefficient 0.04, P = .01) and VD (coefficient 0.09, P = .05) were significantly associated with a faster rate of GCIPL loss. CONCLUSIONS: Lower baseline peripapillary OMAG measurements were significantly associated with a faster rate of GCIPL loss in patients with mild to moderate POAG.
引用
- Rao HL, Dasari S, Puttaiah NK, et al. Optical Microangiography and Progressive Ganglion Cell-Inner Plexiform Layer Loss in Primary Open-Angle Glaucoma. Am J Ophthalmol. 2021. PMID: 34902324. doi:10.1016/j.ajo.2021.11.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。