文献速递青光眼眼底病与葡萄膜炎

扫频源光学相干断层扫描血管成像检测青光眼视盘微血管缺失

Optic Disc Microvasculature Dropout in Glaucoma Detected by Swept-Source Optical Coherence Tomography Angiography.
PubMed 文献 · Am J Ophthalmol · 2021-11-02

这项横断面研究纳入197只原发性开角型青光眼患眼,用扫频源光学相干断层扫描血管成像评估视盘微血管缺失。42.1%无缺失,41.5%存在缺失;缺失组视野平均偏差更差、视网膜神经纤维层更薄,局灶性筛板缺陷和视盘旁深层微血管缺失与视盘微血管缺失强相关。

要点

  • 扫频源光学相干断层扫描血管成像可较好判定原发性开角型青光眼患眼的视盘微血管缺失。
  • 视盘微血管缺失组视野平均偏差更差、平均视网膜神经纤维层更薄。
  • 局灶性筛板缺陷和视盘旁深层微血管缺失与视盘微血管缺失强相关。

核心结论

  • 扫频源光学相干断层扫描血管成像可较好判定原发性开角型青光眼患眼的视盘微血管缺失。
  • 视盘旁深层微血管缺失和局灶性筛板缺陷与视盘微血管缺失强相关。
  • 作者认为扫频源光学相干断层扫描血管成像可作为检测视盘微血管损伤的有用工具。

研究设计与样本

  • 横断面研究,纳入197例原发性开角型青光眼患者的197只眼,均具有可接受质量的扫频源光学相干断层扫描血管成像图像。
  • 采用PLEX Elite 9000(Carl Zeiss Meditec)获取6.0×6.0 mm视盘全信号模式立方扫描,并去除投影伪影。
  • 按视盘微血管缺失情况分为3组:无缺失(第1组)、缺失(第2组,视盘内微血管完全丧失)、无法辨认(第3组,筛板前部显示不清)。

主要发现

  • 82只眼(42.1%)为无视盘微血管缺失(第1组),81只眼(41.5%)为视盘微血管缺失(第2组)。
  • 其余32只眼(16.4%)为无法辨认视盘微血管缺失(第3组),其前部巩膜管开口面积显著更小(P < .05)。
  • 第2组视野平均偏差显著更差、平均视网膜神经纤维层显著更薄、局灶性筛板缺陷和视盘旁深层微血管缺失的患病率显著更高(P < .05)。
  • 多因素logistic回归分析中,局灶性筛板缺陷(比值比46.91;P < .001)和视盘旁深层微血管缺失(比值比48.94;P < .001)仍为与视盘微血管缺失相关的因素。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess the clinical utility of swept-source optical coherence tomography angiography (SS-OCTA) in detecting optic disc microvasculature dropout (MvD-D) in primary open-angle glaucoma (POAG) eyes. DESIGN: Cross-sectional study. METHODS: The study enrolled 197 eyes of 197 patients with POAG with acceptable-quality SS-OCTA (PLEX Elite 9000; Carl Zeiss Meditec) images. A whole-signal-mode 6.0- × 6.0-mm optic disc cube was obtained with projection artifact removal. Three groups were categorized: no MvD-D (group 1), MvD-D (group 2, complete loss of microvasculature within the optic disc), and indiscernible MvD-D (group 3, poor visualization of the anterior lamina cribrosa [LC]). RESULTS: There were 82 (42.1%) and 81 (41.5%) eyes categorized as no MvD-D (group 1) and MvD-D (group 2), respectively. The remaining 32 eyes (16.4%), categorized as indiscernible MvD-D (group 3), had a significantly smaller anterior scleral canal opening (ASCO) area (P < .05). Group 2 had significantly worse visual field (VF) mean deviation (MD), thinner average retinal nerve fiber layer (RNFL), higher prevalence of focal LC defect, and parapapillary deep-layer microvasculature dropout (MvD-P) than the other 2 groups (P < .05). In the multivariable logistic regression analysis, higher prevalence of focal LC defect (odds ratio, 46.91; P < .001) and MvD-P (odds ratio, 48.94; P < .001) remained as factors associated with MvD-D. CONCLUSIONS: The presence of MvD-D could be well determined by SS-OCTA in eyes with POAG. MvD-P and focal LC defects were strongly associated with MvD-D. This suggests that SS-OCTA can serve as a useful tool in detecting optic disc microvasculature damage.

来源:Am J Ophthalmol,查看原文。版权归原作者所有。

引用

  1. Suh MH, Jung DH, Weinreb RN, et al. Optic Disc Microvasculature Dropout in Glaucoma Detected by Swept-Source Optical Coherence Tomography Angiography. Am J Ophthalmol. 2021. PMID: 34740630. doi:10.1016/j.ajo.2021.10.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。