文献速递眼底病与葡萄膜炎

糖尿病视网膜病变眼的光感受器完整性与视网膜血管密度及脉络膜毛细血管的相关性

CORRELATION OF PHOTORECEPTOR INTEGRITY WITH RETINAL VESSEL DENSITY AND CHORIOCAPILLARIS IN EYES WITH DIABETIC RETINOPATHY.
PubMed 文献 · Retina · 2022-01-01

该回顾性研究纳入159只糖尿病视网膜病变眼和30只健康对照眼,采用扫频源光学相干断层扫描血管成像分析中心凹无血管区面积、视网膜浅层和深层毛细血管丛及脉络膜毛细血管血管密度与椭圆体带破坏长度的相关性。结果显示椭圆体带破坏长度与中心凹无血管区面积正相关,与旁中心凹浅层毛细血管丛血管密度、中心凹深层毛细血管丛血管密度及脉络膜毛细血管血管密度负相关。

要点

  • 椭圆体带破坏长度与中心凹无血管区面积正相关(P=0.009)。
  • 椭圆体带破坏长度与旁中心凹浅层毛细血管丛血管密度负相关(P=0.049)。
  • 椭圆体带破坏长度与中心凹深层毛细血管丛及脉络膜毛细血管血管密度负相关(P=0.003、P=0.036)。

核心结论

  • 中心凹无血管区大小和深层毛细血管丛缺血可能在维持糖尿病视网膜病变眼中心凹光感受器完整性中起重要作用。

研究设计与样本

  • 回顾性研究,纳入159只糖尿病视网膜病变眼和30只健康对照眼,均行扫频源光学相干断层扫描血管成像(DRI OCT Triton;Topcon)。

主要发现

  • 在所有眼中,椭圆体带破坏长度与中心凹无血管区面积正相关(P=0.009)。
  • 椭圆体带破坏长度与旁中心凹浅层毛细血管丛血管密度负相关(P=0.049)。
  • 椭圆体带破坏长度与中心凹深层毛细血管丛血管密度负相关(P=0.003)。
  • 椭圆体带破坏长度与中心凹脉络膜毛细血管血管密度负相关(P=0.036)。

局限性

  • 考虑光学相干断层扫描血管成像的伪影(如投影和遮蔽),未来需要研究揭示椭圆体带破坏与脉络膜毛细血管血管密度的相关性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate the correlation of foveal photoreceptor integrity with the vessel density (VD) of the retina and choriocapillaris using swept source optical coherence tomography angiography in eyes with diabetic retinopathy. METHODS: We retrospectively reviewed subjects having eyes with diabetic retinopathy, who underwent optical coherence tomography angiography using swept source optical coherence tomography (DRI OCT Triton; Topcon). We analyzed the area of the foveal avascular zone and VDs of the superficial capillary plexus, deep capillary plexus, and choriocapillaris. The length of the lateral extent of ellipsoid zone disruption, central subfield thickness, and subfoveal choroidal thickness were measured. Furthermore, we analyzed factors that were closely associated with the length of ellipsoid zone disruption. RESULTS: A total of 159 eyes with diabetic retinopathy and 30 healthy control eyes were included in this study. In all eyes, the lengths of ellipsoid zone disruption were positively correlated with the foveal avascular zone area (P = 0.009). However, they were negatively correlated with the parafoveal VD of the superficial capillary plexus (P = 0.049), the foveal VD of deep capillary plexus (P = 0.003), and that of the choriocapillaris (P = 0.036). CONCLUSION: The size of the foveal avascular zone and ischemia at the deep capillary plexus may play an important role in maintaining foveal photoreceptor integrity in eyes with diabetic retinopathy. Considering optical coherence tomography angiography artifacts, such as projection and shadowing, future studies are required to reveal the correlation between ellipsoid zone disruption and the VD of the choriocapillaris.

来源:Retina,查看原文。版权归原作者所有。

引用

  1. Kim JT, Park EJ. CORRELATION OF PHOTORECEPTOR INTEGRITY WITH RETINAL VESSEL DENSITY AND CHORIOCAPILLARIS IN EYES WITH DIABETIC RETINOPATHY. Retina. 2022. PMID: 34743130. doi:10.1097/IAE.0000000000003343

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。