高危HPV E6/E7 mRNA对ASCUS人群的分流效果评价
该研究以2017年河南罗山县312例液基细胞学诊断为ASCUS的女性为对象,均行阴道镜活检病理及HPV E6/E7 mRNA、HR-HPV DNA、HPV16/18检测,以病理为金标准计算分流效能。结果显示HPV E6/E7 mRNA对CIN2+的灵敏度100.0%、特异度77.8%、转诊率24.7%,特异度高于HR-HPV DNA且转诊率更低,结论为其分流效果优于HR-HPV DNA和HPV16/18。
要点
- HPV E6/E7 mRNA分流ASCUS的CIN2+灵敏度100.0%,NPV 100.0%。
- 其特异度77.8%高于HR-HPV DNA的70.2%,转诊率24.7%低于32.1%。
- HPV16/18特异度93.4%但灵敏度仅30.0%。
核心结论
- HPV E6/E7 mRNA检测对ASCUS人群的分流效果在一定条件下优于HR-HPV DNA和HPV16/18。
- 应用HPV E6/E7 mRNA分流ASCUS人群可避免不必要的阴道镜转诊,同时降低宫颈病变漏诊。
研究设计与样本
- 选取2017年河南省信阳市罗山县宫颈癌筛查队列中液基细胞学诊断为ASCUS的312例女性。
- 所有对象行阴道镜活检和病理学检查,并行HPV16/18、HR-HPV DNA和HPV E6/E7 mRNA检测,以病理诊断为金标准计算效能指标。
主要发现
- 312例ASCUS女性年龄为(52.6±7.3)岁,病理诊断为正常者290例。
- 正常290例中HPV E6/E7 mRNA阳性64例(22.1%),HR-HPV DNA阳性86例(29.7%),HPV16/18阳性19例(6.6%)。
- 病理诊断为CIN2(3例)和CIN3级(6例)患者中,HPV E6/E7 mRNA和HR-HPV DNA检测阳性例数均为3和6例。
- HR-HPV DNA灵敏度与HPV E6/E7 mRNA一致,但特异度70.2%(95%CI:64.8,75.1)较低、转诊率32.1%较高,差异均有统计学意义(均P<0.05);HPV16/18特异度93.4%(95%CI:90.0,95.7)较高但灵敏度30.0%(95%CI:10.8,60.3)低。
关键数值与推荐
- HPV E6/E7 mRNA在≥45岁和<45岁年龄组分流灵敏度均为100.0%。
- ≥45岁组特异度79.0%(95%CI:73.7,83.5)高于<45岁组68.3%(95%CI:53.0,80.4),差异无统计学意义(P>0.05)。
临床怎么用
- 对ASCUS人群可采用HPV E6/E7 mRNA检测进行分流,以减少不必要的阴道镜转诊并降低宫颈病变漏诊。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To evaluate the performance of high risk human papilloma virus (HR-HPV) E6/E7 mRNA in triaging women with atypical squamous cells of undetermined signification (ASCUS). Methods: The ASCUS cohort determined by liquid-based cytology test in the cervical cancer screening queue in Luoshan County, Xinyang City, Henan Province 2017 were selected. The population underwent colposcopy biopsy and pathological tests, combined with HPV16 or 18 (HPV16/18), HR-HPV DNA and HPV E6/E7 mRNA test. By using the pathological result as the gold standard, the sensitivity, specificity, positive predictor (PPV), negative prediction (NPV), referral rate and 95% confident interval (CI) of HPV E6/E7 mRNA, HR-HPV DNA, HPV16/18 were calculated, respectively. Results: The average age of 312 ASCUS women was 52.6±7.3 years old. Among the 290 women diagnosed as normal by pathology, 64 (22.1%) were HPV E6/E7 mRNA positive, 86 (29.7%) were HR-HPV DNA positive, and 19 (6.6%) were HPV16/18 positive. All of the cervical intraepithelial neoplasia (CIN) cases determined by pathology were both HPV E6/E7 mRNA and HR-HPV DNA positive. The sensitivity, specificity, PPV, NPV and referral rate of HPV E6/E7 mRNA for predicting CIN2+ lesion in women with ASCUS were 100.0% (95%CI: 72.3, 100.0), 77.8% (95%CI: 72.8, 82.1), 13.0% (95%CI: 7.2, 22.3), 100.0% (95%CI: 98.4, 100.0) and 24.7%. Compared with HPV E6/E7 mRNA, the sensitivity of HR-HPV DNA was similar with HPV E6/E7 mRNA, but with a lower specificity [70.2% (95%CI: 64.8, 75.1), P<0.05], a higher referral rate (32.1%, P<0.05); while HPV 16/18 had a high specificity (93.4%, 95%CI: 90.0, 95.7) and a low sensitivity (30.0%, 95%CI: 10.8, 60.3). Based on the age stratification by age 45, the sensitivity of HPV E6/E7 mRNA in both age groups was 100.0%. The specificity of HPV E6/E7 mRNA in group of ≥45 years was a little higher than that in group of <45 years [79.0% (95%CI: 73.7, 83.5) versus 68.3% (95% CI: 53.0, 80.4)], but the difference was not statistically significant (P>0.05). Conclusions: The ASCUS woman triaging effect of HPV E6/E7 mRNA detection is better than those of HR-HPV and HPV16/18 under certain conditions. The application of HPV E6/E7 mRNA detection to triage ASCUS population can avoid unnecessary colposcopy referral and reduce the missed diagnosis of cervical lesions. 目的: 评价高危型人乳头状瘤病毒E6和E7(HR-HPV E6/E7)mRNA对意义不明的不典型鳞状细胞(ASCUS)人群的分流效果。 方法: 选取2017年河南省信阳市罗山县312例宫颈癌筛查队列中液基细胞学检测结果为ASCUS的人群,所有ASCUS人群均行阴道镜活检和病理学检查,行HPV16或18(HPV16/18)、HR-HPV DNA和HPV E6/E7 mRNA检测,以病理学诊断为金标准,分别计算HPV E6/E7 mRNA、HR-HPV DNA、HPV16/18检测的灵敏度、特异度、阳性预测值(PPV)、阴性预测值(NPV)、转诊率及其95% CI。 结果: 312例ASCUS人群的年龄为(52.6±7.3)岁。病理学诊断为正常的290例人群中,HPV E6/E7 mRNA检测出阳性例数为64例(22.1%),HR-HPV DNA检测出阳性例数为86(29.7%),HPV16/18检测阳性例数为19(6.6%);病理诊断为CIN 2(3例)和CIN 3级(6例)患者中,HPV E6/E7 mRNA和HR-HPV DNA检测的阳性例数均为3和6例。以CIN2+作为疾病终点指标时,HPV E6/E7 mRNA分流ASCUS人群的灵敏度、特异度、PPV、NPV、转诊率分别为100% (95% CI: 72.3~100.0)、77.8% (95% CI: 72.8~82.1)、13.0%(95% CI: 7.2~22.3)、100%(95% CI: 98.4~100.0)、24.7%。与HPV E6/E7 mRNA相比,HR-HPV DNA分流效果的灵敏度与HPV E6/E7 mRNA一致,但特异度低[70.2%(95% CI: 64.8~75.1)],转诊率较高(32.1%),差异均有统计学意义(均P<0.05)。HPV16/18检测的特异度较高(93.4%,95% CI: 90.0~95.7),但灵敏度低(30.0%,95% CI:10.8~60.3)。HPV E6/E7 mRNA检测在≥45岁年龄组和<45岁年龄组中分流的灵敏度均为100%,在≥45岁年龄组中分流的特异度为79.0%(95% CI: 73.7~83.5),比<45岁年龄组的特异度(68.3%,95% CI: 53.0~80.4)高,差异无统计学意义(P>0.05)。 结论: HPV E6/E7 mRNA检测对ASCUS人群的分流效果优于HR-HPV DNA和HPV16/18,其用于ASCUS人群的分流管理可以避免不必要的阴道镜转诊,同时降低宫颈病变的漏诊。.
引用
- Guo Z, Zhao DM, Zhang SK, et al. [Clinical effect evaluation of high risk human papilloma virus E6/E7 mRNA in triaging women with atypical squamous cells of undetermined significance]. Zhonghua Zhong Liu Za Zhi. 2021. PMID: 34695901. doi:10.3760/cma.j.cn112152-20190516-00311
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。