经阴道超声评估绝经后出血模拟队列中黑人与白人女性性能差异
该模拟回顾性队列研究基于SEER 2012-2016等数据,评估经阴道超声子宫内膜厚度阈值(3/4/5毫米)筛查绝经后出血女性以检出子宫内膜癌的性能。
要点
- 4毫米阈值下黑人女性敏感性47.5%,白人女性87.9%。
- 黑人女性AUC 0.57,白人女性0.73,筛查性能更差。
- 黑人女性因子宫肌瘤和非子宫内膜样癌高发,筛查漏诊更多。
核心结论
- 在模拟数据中,经阴道超声子宫内膜厚度筛查可能加剧子宫内膜癌诊断分期的种族差异,黑人女性漏诊约为白人的5倍。
主要发现
- 黑人女性4毫米阈值敏感性47.5%(95%CI 46.0%-49.0%),阳性预测值13.1%(95%CI 12.5%-13.6%),AUC 0.57(95%CI 0.56-0.57)。
- 白人女性4毫米阈值敏感性87.9%(95%CI 87.6%-88.3%),阳性预测值14.6%(95%CI 14.4%-14.7%),AUC 0.73(95%CI 0.73-0.74)。
- 3毫米和5毫米阈值下,黑人女性的敏感性、阳性预测值和AUC也 consistently 低于白人女性。
关键数值与推荐
- 推荐用于提示子宫内膜活检的经阴道超声子宫内膜厚度阈值为3毫米或以上、4毫米或以上、5毫米或以上。
临床怎么用
- 临床医生应意识到经阴道超声子宫内膜厚度筛查在黑人女性中性能较低,可能需结合其他临床因素决定是否活检。
局限性
- 研究为模拟队列,基于登记数据和已发表估计,非真实世界前瞻性验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
IMPORTANCE: Black women in the US with endometrial cancer (EC) are more likely to be diagnosed with advanced-stage disease independent of insured status and histologic type. The most common way of diagnosing EC at early stages is through screening of people with postmenopausal bleeding to detect endometrial thickness (ET). This approach may disproportionately underperform in Black women secondary to a higher prevalence of fibroids and nonendometrioid EC in this population, both of which affect the quality of ET measurement. OBJECTIVE: To compare the performance of recommended transvaginal ultrasonography (TVUS) ET thresholds as a screening method to prompt endometrial biopsy by race in a simulated cohort of symptomatic women. DESIGN, SETTING, AND PARTICIPANTS: In a simulated retrospective cohort study, based on data from Surveillance, Epidemiology, and End Results (SEER) national cancer registry 2012-2016; the US census; and published estimates of ET distribution and fibroid prevalence, diagnostic test characteristics of the 3-mm or more, 4-mm or more, and 5-mm or more ET thresholds for biopsy to capture EC diagnoses were calculated. The simulated cohort was constructed from February 2, 2020 (date of access to SEER data), to August 31, 2020. Analysis occurred from September 30, 2020, to March 30, 2021, including the primary analysis and the sensitivity calculations. MAIN OUTCOMES AND MEASURES: The main outcome measured was accuracy of the TVUS ET threshold to accurately identify cases of EC, measured by sensitivity, negative predictive value, and area under the curve (AUC). RESULTS: A total of 367 073 simulated Black and White women with postmenopausal bleeding were evaluated, including 36 708 with EC. Among Black women, the currently recommended 4-mm or greater ET threshold prompted biopsy for fewer than half of EC cases (sensitivity, 47.5%; 95% CI, 46.0%-49.0%); of women referred for biopsy, 13.1% were EC cases (positive predictive value, 13.1%; 95% CI, 12.5%-13.6%). The AUC for the 4-mm or more threshold was 0.57 (95% CI, 0.56-0.57). In contrast, among the White women, the 4-mm or more threshold led to biopsy for most with EC (sensitivity, 87.9%; 95% CI, 87.6%-88.3%). Of those referred for biopsy, 14.6% had EC (positive predictive value, 14.6%; 95% CI, 14.4%-14.7%); AUC was 0.73 (95% CI, 0.73-0.74). The same variations held for the 3-mm or more and 5-mm or more ET thresholds: sensitivity, positive predictive value, and AUC were consistently lower for Black women than White women. CONCLUSIONS AND RELEVANCE: The findings of this simulated cohort study suggest that use of ET as measured by TVUS to determine the need for EC diagnostic testing in symptomatic women may exacerbate racial disparities in EC stage at diagnosis. In simulated data, TVUS ET screening missed almost 5 times more cases of EC among Black women vs White women owing to the greater prevalence of fibroids and nonendometrioid histologic type in Black women.
引用
- Doll KM, Romano SS, Marsh EE, et al. Estimated Performance of Transvaginal Ultrasonography for Evaluation of Postmenopausal Bleeding in a Simulated Cohort of Black and White Women in the US. JAMA Oncol. 2021. PMID: 34264304. doi:10.1001/jamaoncol.2021.1700
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。