叶酸受体靶向术中分子成像定位肺磨玻璃结节
这项人体试验纳入20例拟行VATS切除的肺GGO患者,术前给予0.025 mg/kg OTL38,评估安全性和荧光预测因素。结果无毒性,21个GGO中20个蓄积OTL38并显荧光;术中近红外成像定位15/21,VATS单独定位10/21(p=0.05),分子成像改变9/21例管理。
要点
- OTL38术中分子成像可安全定位肺GGO,并辅助确认切缘。
- 对胸膜下小于2 cm病灶最有效,深度超过1.5 cm定位受限。
- 分子成像改变9/21例管理,包括改善定位和识别近切缘。
核心结论
- OTL38近红外分子成像为小且外周肺GGO提供安全的术中定位替代方法,并可确认切缘。
研究设计与样本
- 人体试验纳入20例拟行VATS切除的肺GGO受试者,术前接受0.025 mg/kg OTL38。
主要发现
- 无毒性观察到;21个GGO中20个蓄积OTL38并显示荧光。
- 术中近红外成像定位15/21个病灶,VATS单独定位10/21个(p=0.05)。
- 分子成像影响9/21例受试者管理,其中6例改善术中定位、3例识别近切缘。
- 对胸膜下小于2 cm病灶最有效;距胸膜超过1.5 cm的病灶荧光反馈定位受限。
临床怎么用
- 可用于VATS下小且外周肺GGO的术中定位和切缘评估。
- 对深部病灶(距胸膜超过1.5 cm)定位效果有限,需结合其他方法。
局限性
- 样本量小(20例受试者、21个GGO),需未来临床试验与替代定位技术比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Intraoperative localization and resection of ill-defined pulmonary ground-glass opacities (GGOs) during minimally invasive pulmonary resection is technically challenging. Current preoperative techniques to facilitate localization of GGOs include microcoil and hook wire placement, both of which have logistic limitations, carry safety concerns, and do not help with margin assessment. In this clinical trial, we explored an alternative method involving near-infrared molecular imaging with a folate receptor-targeted agent, OTL38, to improve localization of GGOs and confirmation of resection margins. METHODS: In a human trial, 20 subjects with pulmonary GGOs who were eligible for video-assisted thoracoscopic surgery (VATS) resection received 0.025 mg/kg of OTL38 before the resection. The primary objectives were to (1) determine whether use of OTL38 allows safe localization of GGOs and assessment of margins during VATS and (2) determine patient, radiographic, and histopathologic variables that predict the amount of fluorescence during near-infrared imaging. RESULTS: We observed no toxicity. Of the 21 GGOs, 20 accumulated OTL38 and displayed fluorescence upon in situ or back table evaluation. Intraoperatively, near-infrared imaging localized 15 of 21 lesions whereas VATS alone localized 10 of 21 (p = 0.05). The addition of molecular imaging affected care of nine of 21 subjects by improving intraoperative localization (n = 6) and identifying close margins (n = 3). This approach was most effective for subpleural lesions measuring less than 2 cm. For lesions deeper than 1.5 cm from the pleural surface, intraoperative localization using fluorescent feedback was limited. CONCLUSIONS: This approach provides a safe alternative for intraoperative localization of small, peripherally located pulmonary lesions. In contrast to alternative localization techniques, use of OTL38 also allows confirmation of adequate margins. Future studies will compare this approach to alternative localization techniques in a clinical trial.
引用
- Predina JD, Newton A, Corbett C, et al. Localization of Pulmonary Ground-Glass Opacities with Folate Receptor-Targeted Intraoperative Molecular Imaging. J Thorac Oncol. 2018. PMID: 29626619. doi:10.1016/j.jtho.2018.03.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。