文献速递乳腺癌

内乳穿支作为受区血管在早期乳腺癌DIEP皮瓣即刻乳房再造中的应用

[Application of internal mammary perforator as recipient vessels in immediate breast reconstruction using deep inferior epigastric perforator flaps in early breast cancer].
PubMed 文献 · Zhonghua Zhong Liu Za Zhi · 2025-01-01

该回顾性分析纳入2022—2023年10例早期乳腺癌患者,采用内乳穿支(IMP)作为受区血管行腹壁下动脉穿支(DIEP)皮瓣即刻乳房再造。结果显示10例皮瓣全部成活、无明显并发症、乳房外观自然对称,BREAST-Q平均93.5分,随访未见复发或转移。结论认为该技术难度较大但安全可靠、效果满意。

要点

  • IMP作为受区血管行DIEP皮瓣即刻乳房再造,10例皮瓣全部成活。
  • 再造乳房自然柔软、与健侧对称,BREAST-Q平均93.5分。
  • 未见明显手术并发症,随访期间无肿瘤复发或转移。

核心结论

  • 采用IMP作为受区血管行DIEP皮瓣即刻乳房再造虽技术难度较大,但可减少内乳区损伤,严格把握适应证下效果满意且安全可靠。

研究设计与样本

  • 回顾性分析2022年1月至2023年12月10例接受IMP作为受区血管行DIEP皮瓣即刻乳房再造的早期乳腺癌患者临床资料。

主要发现

  • 每例IMP数量为2~3根,分布于第2~4肋。
  • IMP动脉直径(1.15±0.22)mm,静脉直径(1.35±0.19)mm;DIEP直径(1.55±0.28)mm,伴行静脉直径(1.50±0.23)mm。
  • DIEP皮瓣大小10.0 cm×8.0 cm×3.0 cm~12.0 cm×22.0 cm×4.0 cm,平均20.5 cm×11.2 cm×2.8 cm,重量(389.1±51.5)g。
  • 手术时间(574.8±68.1)min;10例皮瓣均成活,再造乳房自然柔软、与健侧对称,未见明显手术并发症。
  • BREAST-Q平均93.5分,随访期间未发生肿瘤复发或转移。

临床怎么用

  • 在严格把握手术适应证的前提下,可考虑将IMP作为早期乳腺癌DIEP皮瓣即刻乳房再造的受区血管选择。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To investigate the clinical application of internal mammary perforator (IMP) as recipient vessels in immediate breast reconstruction using deep inferior epigastric perforator (DIEP) flap. Methods: The clinical data of 10 patients with early breast cancer who underwent DIEP for immediate breast reconstruction using IMP as the recipient vessels from January 2022 to December 2023 were analyzed. The number, position, and diameter of IMP, diameter of DIEP, the size of the flap, the operation time, surgical complications, cosmetic effect of breast, and patients' satisfaction were summarized and analyzed. Results: The number of IMPs was 2-3, and they were distributed in the second to the fourth ribs. The diameter of the IMP artery was (1.15±0.22) mm, and the diameter of the vein was (1.35±0.19) mm. The diameter of the DIEP was (1.55±0.28) mm, and that of its accompanying vein was (1.50±0.23) mm. The sizes of the flaps ranged from 10.0 cm×8.0 cm×3.0 cm to 12.0 cm×22.0 cm×4.0 cm, with an average of 20.5 cm×11.2 cm×2.8 cm. The weight of the flap was (389.1±51.5) g. The operation time was (574.8±68.1) min. All 10 cases of flaps survived. The reconstructed breasts were natural, soft, and symmetrical to the healthy side breasts. There was no obvious operative complication. The average BREAST-Q score of the patients was 93.5. No recurrence or metastasis was found during follow-up. Conclusions: Although technically difficult, using IMP as recipient vessels in DIEP flats for immediate breast reconstruction results in a low complication rate of the injuries in the internal mammary region. Under the premise of strictly adhering to the surgical indications, satisfactory results can be achieved, and it is safe and reliable. 目的: 探讨内乳穿支(IMP)作为受区血管在腹壁下动脉穿支(DIEP)皮瓣即刻乳房再造中的临床应用效果。 方法: 2022—2023年中国医学科学院肿瘤医院深圳医院采用IMP作为受区血管行DIEP皮瓣即刻乳房再造的10例早期乳腺癌患者,收集患者的临床资料,分析IMP的数量、位置、管径,以及供区穿支管径、切取皮瓣大小、手术时间、手术并发症、乳房美容效果和患者满意度。 结果: 每例患者IMP数量为2~3根,分布于第2~4肋。IMP动脉直径为(1.15±0.22)mm,静脉直径为(1.35±0.19)mm。DIEP直径为(1.55±0.28)mm,其伴行静脉直径为(1.50±0.23)mm。DIEP皮瓣大小为10.0 cm×8.0 cm×3.0 cm~12.0 cm×22.0 cm×4.0 cm,平均为20.5 cm×11.2 cm×2.8 cm。DIEP皮瓣重量为(389.1±51.5)g。手术时间为(574.8±68.1)min。10例患者移植皮瓣均成活,再造乳房自然、柔软,与健侧乳房对称,未见明显手术并发症,乳房生活质量问卷评分平均为93.5分。随访期间未发生肿瘤复发或转移。 结论: 采用IMP作为受区血管进行DIEP皮瓣即刻乳房再造,虽然难度较大,但可减少内乳区损伤,在严格把握手术适应证的前提下,可以达到满意的效果,且安全可靠,值得临床推广。.

来源:Zhonghua Zhong Liu Za Zhi,查看原文。版权归原作者所有。

引用

  1. Xie XT, Song JR, Lin DC, et al. [Application of internal mammary perforator as recipient vessels in immediate breast reconstruction using deep inferior epigastric perforator flaps in early breast cancer]. Zhonghua Zhong Liu Za Zhi. 2025. PMID: 41287314. doi:10.3760/cma.j.cn112152-20241203-00550

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。