恶性黑色素瘤的三维组织学计算机模型及其对数字病理学的启示
研究通过切片扫描仪以3微米切面数字化皮肤恶性黑色素瘤,利用开源软件构建首个公开数据和代码的人黑色素瘤三维组织学模型,并由四国九名资深病理学家测试。88.9%的病理学家认为该技术可能在未来10年内进入常规病理,优势包括更好反映解剖结构、三维评估对称性及同时评估不同组织层面,局限包括组织消耗大和计算限制导致分辨率欠佳。
要点
- 成功构建并测试首个公开数据和代码的人黑色素瘤三维组织学模型。
- 88.9%的测试病理学家认为该技术可能在未来10年内进入常规病理。
- 优势含三维评估对称性等,局限含组织消耗大和分辨率欠佳。
核心结论
- 三维组织学模型对癌症及黑色素瘤数字病理学具有前景,但仍有局限需仔细解决。
研究设计与样本
- 通过切片扫描仪以3微米切面数字化皮肤恶性黑色素瘤,利用开源软件构建三维模型。
- 由来自四个国家、具有至少10年黑色素瘤组织学诊断经验的九名病理学家测试模型并讨论体验及对未来病理学的影响。
主要发现
- 成功构建并测试首个公开数据和代码的人黑色素瘤三维组织学模型。
- 88.9%的病理学家认为该技术可能在未来10年内进入常规病理。
- 优势包括更好反映解剖结构、三维评估对称性及同时评估不同组织层面。
- 局限包括组织消耗大和计算限制导致分辨率欠佳。
临床怎么用
- 原文未据此给出推荐。
局限性
- 组织消耗大。
- 计算限制导致分辨率欠佳。
- 三维组织学模型仍有局限需仔细解决。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Historically, cancer diagnoses have been made by pathologists using two-dimensional histological slides. However, with the advent of digital pathology and artificial intelligence, slides are being digitised, providing new opportunities to integrate their information. Since nature is 3-dimensional (3D), it seems intuitive to digitally reassemble the 3D structure for diagnosis. OBJECTIVE: To develop the first human-3D-melanoma-histology-model with full data and code availability. Further, to evaluate the 3D-simulation together with experienced pathologists in the field and discuss the implications of digital 3D-models for the future of digital pathology. METHODS: A malignant melanoma of the skin was digitised via 3 µm cuts by a slide scanner; an open-source software was then leveraged to construct the 3D model. A total of nine pathologists from four different countries with at least 10 years of experience in the histologic diagnosis of melanoma tested the model and discussed their experiences as well as implications for future pathology. RESULTS: We successfully constructed and tested the first 3D-model of human melanoma. Based on testing, 88.9% of pathologists believe that the technology is likely to enter routine pathology within the next 10 years; advantages include a better reflectance of anatomy, 3D assessment of symmetry and the opportunity to simultaneously evaluate different tissue levels at the same time; limitations include the high consumption of tissue and a yet inferior resolution due to computational limitations. CONCLUSIONS: 3D-histology-models are promising for digital pathology of cancer and melanoma specifically, however, there are yet limitations which need to be carefully addressed.
引用
- Kurz A, Krahl D, Kutzner H, et al. A 3-dimensional histology computer model of malignant melanoma and its implications for digital pathology. Eur J Cancer. 2023. PMID: 37690178. doi:10.1016/j.ejca.2023.113294
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。