本研究纳入荷兰和比利时六中心2017至2020年连续接受免疫治疗的转移性非小细胞肺癌患者,提取肺炎出现时胸部CT的影像组学特征构建模型鉴别免疫治疗相关肺炎与其他类型肺炎并进行内部测试。31例(5.6%)发生免疫治疗相关肺炎,41例发生其他类型肺炎(7.4%)。最佳影像组学模型采用75毫米球形感兴趣区,乐观校正AUC为0.83(95%CI 0.77-0.95),阴性预测值80%、阳性预测值79%,在12例影像学判断不确定的病例中有10例给出正确诊断。

要点

  • 免疫治疗相关肺炎31例(5.6%),其他类型肺炎41例(7.4%)。
  • 免疫治疗线数是临床模型中唯一预测因素(二线 vs 一线 OR=0.08,95%CI 0.01-0.77)。
  • 75毫米球形感兴趣区影像组学模型乐观校正AUC为0.83(95%CI 0.77-0.95)。

核心结论

  • 应用于计算机断层扫描的影像组学生物标志物可能支持临床医生对接受免疫治疗的非小细胞肺癌患者肺炎进行鉴别诊断,尤其在影像学评估不确定时。

研究设计与样本

  • 回顾性纳入荷兰和比利时六中心2017至2020年连续接受免疫治疗的转移性非小细胞肺癌患者并识别病因特异性肺炎事件。
  • 从肺炎表现时获得的胸部计算机断层扫描图像中,检查七个感兴趣区(分割肺及围绕炎症的球形/立方体区域)以提取最具预测性的影像组学特征。
  • 模型就区分度、校准和决策获益进行内部测试,并将预测标签与单独的临床和影像学判断进行比较。

主要发现

  • 共审查556例患者,31例(5.6%)发生免疫治疗相关肺炎,41例发生其他类型肺炎(7.4%)。
  • 临床模型中免疫治疗线数是唯一预测因素(二线 vs 一线 OR=0.08,95%CI 0.01-0.77)。
  • 最佳影像组学模型采用75毫米球形感兴趣区,乐观校正受试者工作特征曲线下面积为0.83(95%CI 0.77-0.95),阴性预测值80%、阳性预测值79%。
  • 影像组学模型在整个概率范围内获得良好校准和净获益。
  • 在12例影像学判断不确定的病例中,影像组学模型对10例给出正确诊断。

关键数值与推荐

  • 免疫治疗相关肺炎31例(5.6%),其他类型肺炎41例(7.4%),共审查556例。
  • 临床模型:二线 vs 一线 OR=0.08(95%CI 0.01-0.77)。
  • 最佳影像组学模型:75毫米球形感兴趣区,乐观校正AUC=0.83(95%CI 0.77-0.95),阴性预测值80%,阳性预测值79%。
  • 影像学判断不确定的12例中,影像组学模型正确诊断10例。

临床怎么用

  • 原文结论指出,影像组学生物标志物可能支持临床医生对接受免疫治疗的非小细胞肺癌患者肺炎进行鉴别诊断,尤其在影像学评估不确定时。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Immunotherapy-induced pneumonitis (IIP) is a serious side-effect which requires accurate diagnosis and management with high-dose corticosteroids. The differential diagnosis between IIP and other types of pneumonitis (OTP) remains challenging due to similar radiological patterns. This study was aimed to develop a prediction model to differentiate IIP from OTP in patients with stage IV non-small cell lung cancer (NSCLC) who developed pneumonitis during immunotherapy. METHODS: Consecutive patients with metastatic NSCLC treated with immunotherapy in six centres in the Netherlands and Belgium from 2017 to 2020 were reviewed and cause-specific pneumonitis events were identified. Seven regions of interest (segmented lungs and spheroidal/cubical regions surrounding the inflammation) were examined to extract the most predictive radiomic features from the chest computed tomography images obtained at pneumonitis manifestation. Models were internally tested regarding discrimination, calibration and decisional benefit. To evaluate the clinical application of the models, predicted labels were compared with the separate clinical and radiological judgements. RESULTS: A total of 556 patients were reviewed; 31 patients (5.6%) developed IIP and 41 patients developed OTP (7.4%). The line of immunotherapy was the only predictive factor in the clinical model (2nd versus 1st odds ratio = 0.08, 95% confidence interval:0.01-0.77). The best radiomic model was achieved using a 75-mm spheroidal region of interest which showed an optimism-corrected area under the receiver operating characteristic curve of 0.83 (95% confidence interval:0.77-0.95) with negative and positive predictive values of 80% and 79%, respectively. Good calibration and net benefits were achieved for the radiomic model across the entire range of probabilities. A correct diagnosis was provided by the radiomic model in 10 out of 12 cases with non-conclusive radiological judgements. CONCLUSION: Radiomic biomarkers applied to computed tomography imaging may support clinicians making the differential diagnosis of pneumonitis in patients with NSCLC receiving immunotherapy, especially when the radiologic assessment is non-conclusive.