文献速递乳腺癌

智能多模态剪切波弹性成像减少乳腺癌诊断中不必要的活检(INSPiRED 002):一项回顾性国际多中心分析

Intelligent multi-modal shear wave elastography to reduce unnecessary biopsies in breast cancer diagnosis (INSPiRED 002): a retrospective, international, multicentre analysis.
PubMed 文献 · Eur J Cancer · 2022-09-28

研究基于2016至2019年7国12中心857例接受B超、剪切波弹性成像(SWE)及病理评估的女性数据,训练并外部验证机器学习算法。外部验证集(n=285)中智能多模态SWE敏感度100%、特异度50.3%、AUC 0.93,诊断性能显著优于传统SWE和B超(P<0.001),较B超减少50.3%不必要活检(79 vs 159,P<0.001)且未漏诊癌症。

要点

  • 外部验证集智能多模态SWE敏感度100%(126/126),特异度50.3%(80/159),AUC 0.93。
  • 诊断性能显著高于传统SWE和B超(P<0.001)。
  • 较B超减少50.3%不必要活检(79 vs 159,P<0.001)且未漏诊癌症。

核心结论

  • 使用智能多模态剪切波弹性成像可能安全避免大多数不必要的乳腺活检,结果可能有助于减轻患者、提供者和医疗系统的诊断负担。

研究设计与样本

  • 回顾性、国际、多中心分析,使用2016至2019年7国12个研究中心的857例接受B超、剪切波弹性成像及后续组织病理学评估的女性数据。
  • 在12个中心中11个中心的数据上训练和测试机器学习算法,并用剩余中心的数进行外部验证。

主要发现

  • 外部验证集(n=285)中智能多模态SWE敏感度100%(95%CI 97.1-100%,126/126),特异度50.3%(95%CI 42.3-58.3%,80/159),AUC 0.93(95%CI 0.90-0.96)。
  • 诊断性能显著高于传统SWE和B超(P<0.001)。
  • 与传统SWE不同,智能多模态SWE的阳性预测值显著高于B超。
  • 与B超相比,不必要活检减少50.3%(79 vs 159,P<0.001),且未漏诊癌症。

关键数值与推荐

  • 外部验证集智能多模态SWE敏感度100%(95%CI 97.1-100%,126/126)。
  • 外部验证集智能多模态SWE特异度50.3%(95%CI 42.3-58.3%,80/159)。
  • 外部验证集智能多模态SWE的AUC为0.93(95%CI 0.90-0.96)。
  • 不必要活检较B超减少50.3%(79 vs 159,P<0.001)。

临床怎么用

  • 原文结论认为使用智能多模态SWE可能安全避免大多数不必要的乳腺活检。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Breast ultrasound identifies additional carcinomas not detected in mammography but has a higher rate of false-positive findings. We evaluated whether use of intelligent multi-modal shear wave elastography (SWE) can reduce the number of unnecessary biopsies without impairing the breast cancer detection rate. METHODS: We trained, tested, and validated machine learning algorithms using SWE, clinical, and patient information to classify breast masses. We used data from 857 women who underwent B-mode breast ultrasound, SWE, and subsequent histopathologic evaluation at 12 study sites in seven countries from 2016 to 2019. Algorithms were trained and tested on data from 11 of the 12 sites and externally validated using the additional site's data. We compared findings to the histopathologic evaluation and compared the diagnostic performance between B-mode breast ultrasound, traditional SWE, and intelligent multi-modal SWE. RESULTS: In the external validation set (n = 285), intelligent multi-modal SWE showed a sensitivity of 100% (95% CI, 97.1-100%, 126 of 126), a specificity of 50.3% (95% CI, 42.3-58.3%, 80 of 159), and an area under the curve of 0.93 (95% CI, 0.90-0.96). Diagnostic performance was significantly higher compared to traditional SWE and B-mode breast ultrasound (P < 0.001). Unlike traditional SWE, positive-predictive values of intelligent multi-modal SWE were significantly higher compared to B-mode breast ultrasound. Unnecessary biopsies were reduced by 50.3% (79 versus 159, P < 0.001) without missing cancer compared to B-mode ultrasound. CONCLUSION: The majority of unnecessary breast biopsies might be safely avoided by using intelligent multi-modal SWE. These results may be helpful to reduce diagnostic burden for patients, providers, and healthcare systems.

来源:Eur J Cancer,查看原文。版权归原作者所有。

引用

  1. Pfob A, Sidey-Gibbons C, Barr RG, et al. Intelligent multi-modal shear wave elastography to reduce unnecessary biopsies in breast cancer diagnosis (INSPiRED 002): a retrospective, international, multicentre analysis. Eur J Cancer. 2022. PMID: 36283244. doi:10.1016/j.ejca.2022.09.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。