联合剪切波与应变弹性成像在乳腺癌诊断中减少不必要活检的潜力——一项国际多中心试验

The potential of combined shear wave and strain elastography to reduce unnecessary biopsies in breast cancer diagnostics - An international, multicentre trial.
PubMed 文献 · Eur J Cancer · 2021-12-05

这项前瞻性国际多中心试验纳入1288例BI-RADS 3至4c乳腺肿块患者,评估联合剪切波弹性成像(SWE)与应变弹性成像(SE)重新分类BI-RADS 3-4病变能否减少不必要活检。结果显示,以SWE阈值≥3.70 m/s、SE阈值≥1.0重新分类BI-RADS 4a病变后,不必要活检比例从53.80%(495/920)降至34.78%(320/920),降低35.35%(320 vs 495);新BI-RADS 3队列中漏诊恶性比例为1.96%(12/612),低于ACR BI-RADS 3定义的2%。

要点

  • 联合SWE与SE重新分类BI-RADS 4a病变,不必要活检从53.80%(495/920)降至34.78%(320/920),降低35.35%(320 vs 495)。
  • 新BI-RADS 3队列漏诊恶性比例为1.96%(12/612),低于ACR BI-RADS 3定义的2%。
  • 该策略为探索性定义阈值,结论为可帮助减少约35%不必要活检。

核心结论

  • 在常规B型乳腺超声基础上联合SWE与SE重新分类BI-RADS 4a患者,可帮助将乳腺诊断中的不必要活检减少约35%,同时将未检出恶性比例保持在ACR BI-RADS 3定义的2%以下。

研究设计与样本

  • 本文报告一项前瞻性、多中心、国际试验(NCT02638935)的次要结果。
  • 试验纳入1288例经传统B型乳腺超声诊断为BI-RADS 3至4c乳腺肿块女性。
  • 所有患者接受SWE与SE(指标试验)及组织病理学评估(参考标准)。

主要发现

  • 组织病理学评估显示,1288个乳腺肿块中368个为恶性。
  • 按常规B型乳腺超声评估,53.80%(920例中495例)接受了不必要活检。
  • 以SWE阈值≥3.70 m/s、SE阈值≥1.0重新分类BI-RADS 4a病变后,34.78%(920例中320例)接受不必要活检,相当于不必要活检减少35.35%(320 vs 495)。
  • 新BI-RADS 3队列中漏诊恶性比例为1.96%(612例中12例)。

关键数值与推荐

  • 重新分类BI-RADS 4a病变所用SWE阈值为≥3.70 m/s,SE阈值为≥1.0。
  • 不必要活检定义为良性病变中的活检。
  • 新BI-RADS 3队列漏诊恶性比例为1.96%(12/612),低于ACR BI-RADS 3定义的2%。

临床怎么用

  • 原文结论提出,在常规B型乳腺超声基础上联合SWE与SE重新分类BI-RADS 4a患者,可帮助减少约35%的不必要活检。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Shear wave elastography (SWE) and strain elastography (SE) have shown promising potential in breast cancer diagnostics by evaluating the stiffness of a lesion. Combining these two techniques could further improve the diagnostic performance. We aimed to exploratorily define the cut-offs at which adding combined SWE and SE to B-mode breast ultrasound could help reclassify Breast Imaging Reporting and Data System (BI-RADS) 3-4 lesions to reduce the number of unnecessary breast biopsies. METHODS: We report the secondary results of a prospective, multicentre, international trial (NCT02638935). The trial enrolled 1288 women with BI-RADS 3 to 4c breast masses on conventional B-mode breast ultrasound. All patients underwent SWE and SE (index test) and histopathologic evaluation (reference standard). Reduction of unnecessary biopsies (biopsies in benign lesions) and missed malignancies after recategorising with SWE and SE were the outcome measures. RESULTS: On performing histopathologic evaluation, 368 of 1288 breast masses were malignant. Following the routine B-mode breast ultrasound assessment, 53.80% (495 of 920 patients) underwent an unnecessary biopsy. After recategorising BI-RADS 4a lesions (SWE cut-off ≥3.70 m/s, SE cut-off ≥1.0), 34.78% (320 of 920 patients) underwent an unnecessary biopsy corresponding to a 35.35% (320 versus 495) reduction of unnecessary biopsies. Malignancies in the new BI-RADS 3 cohort were missed in 1.96% (12 of 612 patients). CONCLUSION: Adding combined SWE and SE to routine B-mode breast ultrasound to recategorise BI-RADS 4a patients could help reduce the number of unnecessary biopsies in breast diagnostics by about 35% while keeping the rate of undetected malignancies below the 2% ACR BI-RADS 3 definition.

来源:Eur J Cancer,查看原文。版权归原作者所有。

引用

  1. Golatta M, Pfob A, Büsch C, et al. The potential of combined shear wave and strain elastography to reduce unnecessary biopsies in breast cancer diagnostics - An international, multicentre trial. Eur J Cancer. 2021. PMID: 34879299. doi:10.1016/j.ejca.2021.11.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。