基于卷积神经网络的123I-MIBG SPECT心脏自动分割与定量
本研究纳入48例心脏及神经系统疾病患者,训练卷积神经网络(CNN)对123I-MIBG SPECT图像进行心脏分割,自动计算心脏计数和洗脱率(WR),并与平面显像定量比较。CNN-based SPECT心脏计数与平面心脏计数显著相关(R²=0.862,p<0.0001),WR也相关(R²=0.584,p<0.0001),高低WR分类一致率87.2%。
要点
- CNN可自动分割123I-MIBG SPECT心脏区域并计算心脏计数和洗脱率
- CNN-based SPECT心脏计数与平面计数显著相关(R²=0.862)
- CNN-based与平面WR分类一致率为87.2%
核心结论
- CNN可从123I-MIBG SPECT图像中分割心脏,三维计算平均心脏计数和WR,与平面定量可靠相关。
研究设计与样本
- 回顾性研究,纳入48例心脏和神经系统疾病患者(年龄68.4±11.7岁),包括慢性心力衰竭、路易体痴呆和帕金森病,所有患者接受早期和晚期123I-MIBG平面及SPECT显像。
- CNN先训练分割早期和晚期SPECT图像中的肺和肝,对齐分割掩膜后直接训练分割心脏,所有模型采用四折交叉验证评估。
主要发现
- CNN-based SPECT心脏计数与常规平面心脏计数(有无背景校正)显著相关,R²分别为0.862、0.827和0.729(p<0.0001)。
- CNN-based与平面WR(有无背景校正及基于心纵隔比的WR)相关,R²分别为0.584、0.568和0.507(p<0.0001)。
- 以平面WR cutoff 34%、SPECT WR cutoff 30%分类高低WR,CNN-based与平面方法一致率为87.2%。
关键数值与推荐
- 平面WR cutoff为34%,SPECT WR cutoff为30%,用于高低WR分类。
- CNN-based SPECT心脏计数与平面心脏计数相关系数R²=0.862(无背景校正时)。
- CNN-based与平面WR相关系数R²=0.584(无背景校正时)。
临床怎么用
- CNN可自动三维分割123I-MIBG SPECT心脏并计算心脏计数和WR,有望成为神经支配SPECT图像定量的新方法。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Since three-dimensional segmentation of cardiac region in 123I-metaiodobenzylguanidine (MIBG) study has not been established, this study aimed to achieve organ segmentation using a convolutional neural network (CNN) with 123I-MIBG single photon emission computed tomography (SPECT) imaging, to calculate heart counts and washout rates (WR) automatically and to compare with conventional quantitation based on planar imaging. METHODS: We assessed 48 patients (aged 68.4 ± 11.7 years) with heart and neurological diseases, including chronic heart failure, dementia with Lewy bodies, and Parkinson's disease. All patients were assessed by early and late 123I-MIBG planar and SPECT imaging. The CNN was initially trained to individually segment the lungs and liver on early and late SPECT images. The segmentation masks were aligned, and then, the CNN was trained to directly segment the heart, and all models were evaluated using fourfold cross-validation. The CNN-based average heart counts and WR were calculated and compared with those determined using planar parameters. The CNN-based SPECT and conventional planar heart counts were corrected by physical time decay, injected dose of 123I-MIBG, and body weight. We also divided WR into normal and abnormal groups from linear regression lines determined by the relationship between planar WR and CNN-based WR and then analyzed agreement between them. RESULTS: The CNN segmented the cardiac region in patients with normal and reduced uptake. The CNN-based SPECT heart counts significantly correlated with conventional planar heart counts with and without background correction and a planar heart-to-mediastinum ratio (R2 = 0.862, 0.827, and 0.729, p < 0.0001, respectively). The CNN-based and planar WRs also correlated with and without background correction and WR based on heart-to-mediastinum ratios of R2 = 0.584, 0.568 and 0.507, respectively (p < 0.0001). Contingency table findings of high and low WR (cutoffs: 34% and 30% for planar and SPECT studies, respectively) showed 87.2% agreement between CNN-based and planar methods. CONCLUSIONS: The CNN could create segmentation from SPECT images, and average heart counts and WR were reliably calculated three-dimensionally, which might be a novel approach to quantifying SPECT images of innervation.
引用
- Saito S, Nakajima K, Edenbrandt L, et al. Convolutional neural network-based automatic heart segmentation and quantitation in 123I-metaiodobenzylguanidine SPECT imaging. EJNMMI Res. 2021. PMID: 34637028. doi:10.1186/s13550-021-00847-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。