慢性血栓栓塞性肺动脉高压患者心脏成纤维细胞活化的显像研究
结果显示77%的患者右心室存在异常摄取,主要位于游离壁,且与右心室壁厚度和收缩功能指标相关,但与CMR参数无相关性。
要点
- CTEPH患者右心室游离壁68Ga-FAPI-04摄取增高,提示局部成纤维细胞活化。
- 摄取程度与右心室壁厚度正相关,与右心室收缩功能指标负相关。
核心结论
- CTEPH患者心脏成纤维细胞活化主要定位于右心室游离壁,且与右心室壁增厚和收缩功能下降相关。
主要发现
- 患者TBRRV为2.4 ± 0.9,显著高于对照的1.0 ± 0.1(P < 0.001)。
- TBRRV与右心室壁厚度呈正相关(r = 0.815,P = 0.001)。
- TBRRV与右心室面积变化分数呈负相关(r = -0.804,P = 0.001),与三尖瓣环收缩期位移呈负相关(r = -0.678,P = 0.011)。
- 68Ga-FAPI-04摄取与CMR参数间未发现相关性。
关键数值与推荐
- 心脏68Ga-FAPI-04摄取高于血池定义为异常。
- 以左心室侧壁活性为背景计算右心室靶本比(TBRRV)。
临床怎么用
- 68Ga-FAPI-04 PET/CT可无创显示CTEPH患者右心室成纤维细胞活化,辅助评估右心室重构与功能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The aim of this study was to explore the association of cardiac fibroblast activation with clinical parameters and cardiovascular magnetic resonance (CMR) imaging parameters in patients with chronic thromboembolic pulmonary hypertension (CTEPH). METHODS: Thirteen CTEPH patients were prospectively enrolled. All of the patients underwent cardiac 68Gallium-labelled fibroblast activation protein inhibitor (68 Ga-FAPI-04)-positron emission tomography/computed tomography (PET/CT), right heart catheterisation, and echocardiography, and 11 of them additionally underwent CMR. Thirteen control subjects were selected to establish the normal range of cardiac 68 Ga-FAPI-04 uptake. Cardiac 68 Ga-FAPI-04 uptake higher than that in the blood pool was defined as abnormal. The global and segmental maximum standardised uptake values (SUVmax) of the right ventricle (RV) were measured and further expressed as target-to-background ratio (TBRRV) with left ventricular lateral wall activity as background. Late gadolinium enhancement (LGE) was visually evaluated, and native-T1 times, enhanced-T1 times, and extracellular volume (ECV) were quantitatively measured. RESULTS: Ten CTEPH patients (77%) had abnormal 68 Ga-FAPI-04 uptake in RV, mainly located in the free wall, which was significantly higher than that in controls (TBRRV: 2.4 ± 0.9 vs 1.0 ± 0.1, P < 0.001). The TBRRV correlated positively with the thickness of RV wall (r = 0.815, P = 0.001) and inversely with RV fraction area change (RVFAC) (r = - 0.804, P = 0.001) and tricuspid annular plane systolic excursion (TAPSE) (r = - 0.678, P = 0.011). No correlation was found between 68 Ga-FAPI-04 activity and CMR imaging parameters. CONCLUSION: Fibroblast activation in CTEPH, measured by 68 Ga-FAPI-04 imaging, is mainly localised in the RV free wall. Enhanced fibroblast activation reflects the thickening of the RV wall and decreased RV contractile function.
引用
- Chen BX, Xing HQ, Gong JN, et al. Imaging of cardiac fibroblast activation in patients with chronic thromboembolic pulmonary hypertension. Eur J Nucl Med Mol Imaging. 2021. PMID: 34651221. doi:10.1007/s00259-021-05577-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。