疑似ATTR心脏淀粉样变患者心肌99mTc-DPD摄取定量SPECT/CT参数
结果显示SUVmax及SMaT阈值分割可极好区分视觉分级2/3级与0/1级,SUVmax、SMaT20、40、60的截断值分别为6.0、2.5、3和4,PPV与NPV均为100%;SMaT20、40、60(心脏)/SUVmean(肝脏)及SMaT20、40、60(心脏)/SUVmean(肝/肺)可区分2级与3级。
要点
- 定量SPECT/CT参数可区分心肌摄取2/3级与0/1级。
- SUVmax截断值6.0时区分2/3级与0/1级PPV和NPV均为100%。
- SMaT20、40、60(心脏)/SUVmean(肝脏)可区分2级与3级。
核心结论
- 心肌99mTc-DPD摄取的定量SPECT/CT参数稳健,可区分视觉分级2/3级与0/1级患者。
研究设计与样本
- 三名操作者独立采用半自动阈值分割法测量心肌SUVmax及阈值(SUVmax的20%、40%、60%)以上的SUVmean(SMaT)。
- 定量结果与心脏摄取视觉分级(0-3级)进行比较。
主要发现
- SUVmax及SMaT阈值分割可极好区分2/3级与0/1级,操作者间及操作者内相关性极好。
- SUVmax、SMaT20、SMaT40、SMaT60的截断值分别为6.0、2.5、3和4时,区分2/3级与0/1级的PPV和NPV均为100%。
- SMaT20、40、60(心脏)/SUVmean(肝脏)及SMaT20、40、60(心脏)/SUVmean(肝/肺)可区分2级与3级。
关键数值与推荐
- SUVmax截断值6.0区分视觉分级2/3级与0/1级,PPV和NPV均为100%。
- SMaT20截断值2.5区分视觉分级2/3级与0/1级,PPV和NPV均为100%。
- SMaT40截断值3区分视觉分级2/3级与0/1级,PPV和NPV均为100%。
- SMaT60截断值4区分视觉分级2/3级与0/1级,PPV和NPV均为100%。
临床怎么用
- 对疑似ATTR患者,可采用半自动阈值分割定量SPECT/CT测量心肌99mTc-DPD摄取,辅助区分视觉分级2/3级与0/1级。
- SMaT20、40、60(心脏)/SUVmean(肝脏)及SMaT20、40、60(心脏)/SUVmean(肝/肺)比值有助于区分视觉2级与3级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: 99mTc-labelled bisphosphonates are used for imaging assessment of patients with transthyretin cardiac amyloidosis (ATTR). Present study evaluates whether quantitative SPECT/CT measurement of absolute myocardial 99mTc-labelled 3,3-diphosphono-1,2-propanodicarboxylic acid (Tc-DPD) uptake can diagnose patients with suspected ATTR. METHODS: Twenty-eight patients (25 male, age 80.03 ± 6.99 years) with suspected ATTR referred for Tc-DPD imaging had planar and SPECT/CT imaging of the chest. Three operators independently obtained Tc-DPD myocardial SUVmax and SUVmean above threshold (SMaT) (20, 40 and 60% of SUVmax), using a semi-automated threshold segmentation method. Results were compared to visual grading (0-3) of cardiac uptake. RESULTS: Twenty-two patients (78%) had cardiac uptake (2 grade 1, 15 grade 2, 5 grade 3). SUVmax and SMaT segmentation thresholds enabled separating grades 2/3 from 0/1 with excellent inter- and intra-reader correlation. Cut-off values 6.0, 2.5, 3 and 4 for SUVmax, SMaT20,40,60, respectively, separated between grades 2/3 and 0 /1 with PPV and NPV of 100%. SMaT20,40,60(cardiac)/SUVmean (liver) and SMaT20,40,60(cardiac)/SUVmean(liver/lung) separated grades 2 and 3. CONCLUSION: Quantitative SPECT/CT parameters of cardiac Tc-DPD uptake are robust, enabling separation of patients with grades 2 and 3 cardiac uptake from grades 0 and 1. Larger patient cohorts will determine the incremental value of SPECT/CT quantification for ATTR management.
引用
- Ben-Haim S, Chicheportiche A, Goshen E, et al. Quantitative SPECT/CT parameters of myocardial 99mTechnetium-3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) uptake in suspected cardiac transthyretin amyloidosis. EJNMMI Res. 2021. PMID: 34487268. doi:10.1186/s13550-021-00828-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。