冠脉钙化积分在SPECT与PET心肌灌注显像报告中的附加价值比较
该回顾性研究将206例Rb-82 PET患者与倾向性匹配的206例镉锌碲SPECT患者对比,构建四组图像由两名医师判读。PET判读为正常的比例高于SPECT(88% vs 80%,P=0.015);加用CACS后SPECT正常比例升至86%(P=0.014),而PET无此效应(90%,P=0.77)。正常图像的年化事件率无差异(0.7–2.0%,P>0.084)。
要点
- PET心肌灌注显像判读为正常的比例高于SPECT(88% vs 80%)。
- 加用CACS可提高SPECT正常判读比例,但对PET无附加效应。
- 正常图像年化事件率在两组间无差异,介于0.7–2.0%。
核心结论
- 加用CACS可正确提高SPECT MPI正常判读比例,但对PET无此效应,可能限制CACS对PET报告的价值。
研究设计与样本
- 回顾性纳入412例患者,206例Rb-82 PET经倾向性匹配与4018例镉锌碲SPECT中的206例配对。
- 构建SPECT-only、PET-only、SPECT+CACS、PET+CACS四组共824幅图像,由两名医师判读为正常、不确定或异常。
- 随访30个月比较PET与SPECT组的事件率。
主要发现
- PET判读为正常的比例高于SPECT(88% vs 80%,P=0.015)。
- 加用CACS后SPECT正常比例升至86%(P=0.014),PET为90%(P=0.77)无显著变化。
- 正常图像的年化事件率组间无差异,介于0.7–2.0%(P>0.084)。
关键数值与推荐
- 判读分类为正常、不确定或异常(缺血或不可逆缺损)。
- PET正常比例88% vs SPECT 80%,P=0.015。
- SPECT+CACS正常比例86%,P=0.014;PET+CACS正常比例90%,P=0.77。
- 正常图像年化事件率0.7–2.0%,P>0.084。
临床怎么用
- SPECT MPI报告可结合CACS以提高正常判读的准确性。
- PET MPI报告加用CACS的附加价值可能有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Knowledge of coronary artery calcium score (CACS) influences the interpretation of myocardial perfusion imaging (MPI) with SPECT; however, the impact on PET interpretation remains unclear. We compared the added value of CACS to reporting MPI using SPECT vs PET. METHODS: We retrospectively included 412 patients. 206 patients who underwent Rb-82 PET were propensity-based matched to a cohort of 4018 patients who underwent cadmium-zinc-telluride SPECT MPI to obtain a comparable group of 206 SPECT patients. Next, we created four image sets: SPECT MPI-only, PET-only, SPECT + CACS, and PET + CACS. Two physicians interpreted the 824 images as normal, equivocal, or abnormal for ischemia or irreversible defects. Additionally, event rates were compared between PET and SPECT groups during 30-month follow-up. RESULTS: PET yielded more scans interpreted as normal than SPECT (88% vs 80%, respectively, P = 0.015). Adding CACS to SPECT increased the percentage of normal scans to 86% (P = 0.014), whereas this effect was absent for PET (90%, P = 0.77). Annualized event rates for images interpreted as normal did not differ and varied between 0.7 and 2.0% (P > 0.084). CONCLUSION: Adding CACS correctly increased the percentage of normal scans for SPECT MPI but not for PET, possibly limiting the effect of adding CACS to reporting PET.
引用
- Mouden M, Jager PL, van Dalen JA, et al. Added value of coronary artery calcium score in the reporting of SPECT versus PET myocardial perfusion imaging. J Nucl Cardiol. 2021. PMID: 34476779. doi:10.1007/s12350-021-02789-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。