文献速递骨显像与常规 SPECT肿瘤 PET/CT

深度学习模型在前列腺癌全身骨显像中检测骨转移的诊断效能

Diagnostic performance of deep learning models for detecting bone metastasis on whole-body bone scan in prostate cancer.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2021-08-07

该研究纳入9113例前列腺癌患者的全身骨显像,比较全身整体(WB)与全局-局部统一强调(GLUE)两种2D卷积神经网络架构检测骨转移的表现。在充足训练数据下两模型AUC均达优秀水平且多数折间无显著差异;在有限数据下GLUE的AUC显著高于WB模型。

要点

  • GLUE与WB模型在充足训练数据下AUC分别为0.936-0.955与0.933-0.957。
  • GLUE总体准确率0.900,WB为0.889。
  • 有限数据下GLUE的AUC 0.894-0.908显著高于WB的0.870-0.877(P<0.0001)。

核心结论

  • 2D-CNN模型可准确分类前列腺癌患者的骨显像。
  • 充足数据下两模型均表现优秀,有限数据下GLUE优于WB模型。

研究设计与样本

  • 回顾性评估9113例连续骨显像(5342例前列腺癌患者),以临床报告和图像复核为参考标准标注阳性/阴性。
  • 提出两种2D卷积神经网络架构:全身整体(WB)与整合全身及局部斑块的串联架构(GLUE)。
  • 分别用充足训练数据(72%:8%:20%)与有限训练数据(10%:40%:50%)训练,测试集轮转分配,分别获得五折与二折交叉验证结果。

主要发现

  • 输入共2991例阳性与6142例阴性骨显像。
  • 充足训练下GLUE的AUC为0.936-0.955,WB为0.933-0.957,五折中有四折P>0.05。
  • 充足训练下GLUE总体准确率0.900,WB为0.889。
  • 有限训练下GLUE的AUC为0.894-0.908,显著高于WB的0.870-0.877(P<0.0001)。

临床怎么用

  • 在前列腺癌骨显像判读中可考虑采用2D-CNN辅助检测骨转移。
  • 训练数据有限时GLUE架构可能较WB架构更具优势。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We evaluated the performance of deep learning classifiers for bone scans of prostate cancer patients. METHODS: A total of 9113 consecutive bone scans (5342 prostate cancer patients) were initially evaluated. Bone scans were labeled as positive/negative for bone metastasis using clinical reports and image review for ground truth diagnosis. Two different 2D convolutional neural network (CNN) architectures were proposed: (1) whole body-based (WB) and (2) tandem architectures integrating whole body and local patches, here named as "global-local unified emphasis" (GLUE). Both models were trained using abundant (72%:8%:20% for training:validation:test sets) and limited training data (10%:40%:50%). The allocation of test sets was rotated across all images: therefore, fivefold and twofold cross-validation test results were available for abundant and limited settings, respectively. RESULTS: A total of 2991 positive and 6142 negative bone scans were used as input. For the abundant training setting, the receiver operating characteristics curves of both the GLUE and WB models indicated excellent diagnostic ability in terms of the area under the curve (GLUE: 0.936-0.955, WB: 0.933-0.957, P > 0.05 in four of the fivefold tests). The overall accuracies of the GLUE and WB models were 0.900 and 0.889, respectively. With the limited training setting, the GLUE models showed significantly higher AUCs than the WB models (0.894-0.908 vs. 0.870-0.877, P < 0.0001). CONCLUSION: Our 2D-CNN models accurately classified bone scans of prostate cancer patients. While both showed excellent performance with the abundant dataset, the GLUE model showed higher performance than the WB model in the limited data setting.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Han S, Oh JS, Lee JJ, et al. Diagnostic performance of deep learning models for detecting bone metastasis on whole-body bone scan in prostate cancer. Eur J Nucl Med Mol Imaging. 2021. PMID: 34363089. doi:10.1007/s00259-021-05481-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。