文献速递心脏核医学

动态CZT-SPECT诊断冠心病的系统评价与荟萃分析

Diagnostic accuracy of dynamic CZT-SPECT in coronary artery disease. A systematic review and meta-analysis.
PubMed 文献 · J Nucl Cardiol · 2021-08-04

该系统评价与荟萃分析纳入9项研究共421例患者,评估动态CZT-SPECT心肌灌注显像对比定量冠状动脉造影、血流储备分数和PET诊断冠心病的准确性,汇总敏感度为0.79(95%CI 0.73–0.85),特异度为0.85(95%CI 0.74–0.92),但研究间方法学异质性较大且纳入研究较少。

要点

  • 动态CZT-SPECT诊断冠心病的汇总敏感度为0.79,特异度为0.85。
  • 诊断比值比为17.82(95%CI 8.80–36.08,P<0.001)。
  • 阳性似然比3.86,阴性似然比0.21,提示阴性结果排除价值较好。

核心结论

  • 动态CZT-SPECT心肌灌注显像对比金标准诊断冠心病具有较好的敏感度和特异度。

研究设计与样本

  • 系统评价与荟萃分析,检索PubMed、OvidSP(Medline)、Web of Science、Cochrane Library和EMBASE至2020年7月5日,最终纳入9项研究共421例患者,采用双变量模型进行汇总分析,并以QUADAS-2评估质量。

主要发现

  • 动态CZT-SPECT诊断冠心病的汇总敏感度为0.79(95%CI 0.73–0.85),特异度为0.85(95%CI 0.74–0.92)。
  • 诊断比值比为17.82(95%CI 8.80–36.08,P<0.001)。
  • 阳性似然比为3.86(95%CI 2.76–5.38,P<0.001),阴性似然比为0.21(95%CI 0.13–0.33,P<0.001)。

关键数值与推荐

  • 纳入标准为随机对照试验、回顾性试验或观察性研究,针对冠心病诊断,且动态CZT-SPECT与参考方法检查间隔在半年内。
  • 仅基于CAG将50%–70%冠状动脉狭窄视为显著的研究被排除。

临床怎么用

  • 动态CZT-SPECT可作为冠心病无创诊断的参考手段,其阴性似然比0.21提示阴性结果对排除冠心病有一定价值。
  • 因研究间方法学异质性和纳入研究数量较少,临床应用时需结合具体方案和患者情况解读结果。

局限性

  • CZT-SPECT研究间方法学存在异质性。
  • 纳入研究数量相对较少,需要进一步设计良好的研究方案。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: With the appearance of cadmium-zinc-telluride (CZT) cameras, dynamic myocardial perfusion imaging (MPI) has been introduced, but comparable data to other MPI modalities, such as quantitative coronary angiography (CAG) with fractional flow reserve (FFR) and positron emission tomography (PET), are lacking. This study aimed to evaluate the diagnostic accuracy of dynamic CZT single-photon emission tomography (SPECT) in coronary artery disease compared to quantitative CAG, FFR, and PET as reference. MATERIALS AND METHODS: Different databases were screened for eligible citations performing dynamic CZT-SPECT against CAG, FFR, or PET. PubMed, OvidSP (Medline), Web of Science, the Cochrane Library, and EMBASE were searched on the 5th of July 2020. Studies had to meet the following pre-established inclusion criteria: randomized controlled trials, retrospective trails or observational studies relevant for the diagnosis of coronary artery disease, and performing CZT-SPECT and within half a year the methodological references. Studies which considered coronary stenosis between 50% and 70% as significant based only on CAG were excluded. Data extracted were sensitivity, specificity, likelihood ratios, and diagnostic odds ratios. Quality was assessed with QUADAS-2 and statistical analysis was performed using a bivariate model. RESULTS: Based on our criteria, a total of 9 studies containing 421 patients were included. For the assessment of CZT-SPECT, the diagnostic value pooled analysis with a bivariate model was calculated and yielded a sensitivity of 0.79 (% CI 0.73 to 0.85) and a specificity of 0.85 (95% CI 0.74 to 0.92). Diagnostic odds ratio (DOR) was 17.82 (95% CI 8.80 to 36.08, P < 0.001). Positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 3.86 (95% CI 2.76 to 5.38, P < 0.001) and 0.21 (95% CI 0.13 to 0.33, P < 0.001), respectively. CONCLUSION: Based on the results of the current systematic review and meta-analysis, dynamic CZT-SPECT MPI demonstrated a good sensitivity and specificity to diagnose CAD as compared to the gold standards. However, due to the heterogeneity of the methodologies between the CZT-SPECT MPI studies and the relatively small number of included studies, it warrants further well-defined study protocols.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Panjer M, Dobrolinska M, Wagenaar NRL, et al. Diagnostic accuracy of dynamic CZT-SPECT in coronary artery disease. A systematic review and meta-analysis. J Nucl Cardiol. 2021. PMID: 34350553. doi:10.1007/s12350-021-02721-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。