比活度对18F-rhPSMA-7.3生物分布的影响:临床PET数据回顾性分析
本研究回顾性比较了高比活度(中位178.9 MBq/µg,n=42)与低比活度(中位19.3 MBq/µg,n=42)18F-rhPSMA-7.3 PET/CT在前列腺癌患者中的生物分布。低比活度组腮腺、颌下腺和脾脏的摄取中度但显著降低,其他正常器官和肿瘤病灶未见统计学显著差异。结论认为比活度降低约10倍对18F-rhPSMA-7.3生物分布影响轻微,支持18F标记PSMA配体可集中生产并配送至PET中心。
要点
- 比活度降低约10倍仅使腮腺、颌下腺和脾脏摄取中度降低。
- 其他正常器官和肿瘤病灶的摄取未见统计学显著差异。
- 18F标记PSMA配体或可像18F-FDG一样集中生产并配送。
核心结论
- 比活度降低约10倍对18F-rhPSMA-7.3的生物分布仅产生轻微影响。
- 18F标记的PSMA配体可集中生产并配送至PET临床使用。
研究设计与样本
- 回顾性分析临床PET数据,比较高比活度组(中位178.9 MBq/µg,n=42)与低比活度组(中位19.3 MBq/µg,n=42)前列腺癌患者的18F-rhPSMA-7.3 PET/CT生物分布。
主要发现
- 低比活度组腮腺摄取中位SUVmean为16.7,高比活度组为19.2,差异显著。
- 低比活度组颌下腺摄取中位SUVmean为18.1,高比活度组为22.3,差异显著。
- 低比活度组脾脏摄取中位SUVmean为7.8,高比活度组为9.6,差异显著。
- 其他正常器官和肿瘤病灶未见统计学显著差异。
临床怎么用
- 18F-rhPSMA-7.3可集中生产并配送到PET中心,无需因比活度下降而调整临床流程。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
We investigated whether the time between synthesis and injection and the resulting decrease in specific activity affects the normal-organ and tumor uptake of the PSMA ligand 18F-rhPSMA-7.3 in patients with prostate cancer. Methods: The biodistribution of 18F-rhPSMA-7.3 on PET/CT scans obtained with a high specific activity (median, 178.9 MBq/µg; n = 42) and a low specific activity (median, 19.3 MBq/µg; n = 42) was compared. Results: Tracer uptake by the parotid gland, submandibular gland, and spleen was moderately but significantly lower in the low-specific-activity group than in the high-specific-activity group (median SUVmean, 16.7 vs. 19.2; 18.1 vs. 22.3; and 7.8 vs. 9.6, respectively). No other statistically significant differences were found for normal organs or tumor lesions. Conclusion: A 10-fold decrease in specific activity has only minor effects on the biodistribution of 18F-rhPSMA-7.3. These findings suggest that 18F-labeled PSMA ligands can be centrally produced and shipped to PET clinics in a similar way to 18F-FDG.
引用
- Langbein T, Wurzer A, Gafita A, et al. The Influence of Specific Activity on the Biodistribution of 18F-rhPSMA-7.3: A Retrospective Analysis of Clinical PET Data. J Nucl Med. 2021. PMID: 34385338. doi:10.2967/jnumed.121.262471