文献速递肿瘤 PET/CT

AI增强的同步多参数18F-FDG PET/MRI用于乳腺癌精准诊断

AI-enhanced simultaneous multiparametric 18F-FDG PET/MRI for accurate breast cancer diagnosis.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2021-08-10

该前瞻性研究纳入102例患者共120个乳腺病灶(101恶性、19良性),评估结合定量参数与影像组学特征的放射组学与机器学习模型能否鉴别乳腺病灶良恶性。整合MTT、ADC及PET与ADC影像组学特征的模型诊断乳腺癌准确率最高(AUC 0.983),但与专家阅片(AUC 0.868)差异无统计学意义(p=0.508)。

要点

  • 同步多参数18F-FDG PET/MRI的放射组学与机器学习模型可准确鉴别乳腺病灶良恶性。
  • 整合MTT、ADC与PET及ADC影像组学特征的模型AUC达0.983。
  • 该模型准确率与专家阅片(AUC 0.868)相比差异无统计学意义(p=0.508)。

核心结论

  • 结合同步多参数18F-FDG PET/MRI定量参数与影像组学特征的放射组学与机器学习模型能准确鉴别乳腺病灶良恶性。

研究设计与样本

  • 前瞻性纳入102例患者共120个乳腺病灶(101个恶性、19个良性),病灶经超声和/或钼靶检出,均因诊断目的接受混合18F-FDG PET/MRI检查。
  • 采用精细高斯支持向量机算法,通过五折交叉验证探索定量参数与影像组学特征的不同组合,构建诊断模型并以McNemar检验与专家阅片比较性能。

主要发现

  • 共开发8个放射组学模型。
  • 整合MTT、ADC与PET及ADC图像提取的影像组学特征的模型诊断乳腺癌准确率最高(AUC 0.983)。
  • 该模型准确率与专家阅片(AUC 0.868)相比差异无统计学意义(p=0.508)。

关键数值与推荐

  • 定量参数包括DCE的MTT、VD、PF,DW的病灶及对侧乳腺实质平均ADC,PET的病灶SUVmax、SUVmean、SUVminimum及对侧乳腺实质SUVmean,以及T2加权图像。
  • 影像组学特征从DCE、T2加权、ADC及PET图像提取。
  • 最佳模型AUC 0.983,专家阅片AUC 0.868,McNemar检验p=0.508。

临床怎么用

  • 对于超声和/或钼靶检出的乳腺病灶,可考虑用同步多参数18F-FDG PET/MRI放射组学与机器学习模型辅助鉴别良恶性。
  • 模型与专家阅片准确率差异无统计学意义,提示其可作为辅助判读工具而非替代专家阅片。

局限性

  • 原文摘要未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess whether a radiomics and machine learning (ML) model combining quantitative parameters and radiomics features extracted from simultaneous multiparametric 18F-FDG PET/MRI can discriminate between benign and malignant breast lesions. METHODS: A population of 102 patients with 120 breast lesions (101 malignant and 19 benign) detected on ultrasound and/or mammography was prospectively enrolled. All patients underwent hybrid 18F-FDG PET/MRI for diagnostic purposes. Quantitative parameters were extracted from DCE (MTT, VD, PF), DW (mean ADC of breast lesions and contralateral breast parenchyma), PET (SUVmax, SUVmean, and SUVminimum of breast lesions, as well as SUVmean of the contralateral breast parenchyma), and T2-weighted images. Radiomics features were extracted from DCE, T2-weighted, ADC, and PET images. Different diagnostic models were developed using a fine Gaussian support vector machine algorithm which explored different combinations of quantitative parameters and radiomics features to obtain the highest accuracy in discriminating between benign and malignant breast lesions using fivefold cross-validation. The performance of the best radiomics and ML model was compared with that of expert reader review using McNemar's test. RESULTS: Eight radiomics models were developed. The integrated model combining MTT and ADC with radiomics features extracted from PET and ADC images obtained the highest accuracy for breast cancer diagnosis (AUC 0.983), although its accuracy was not significantly higher than that of expert reader review (AUC 0.868) (p = 0.508). CONCLUSION: A radiomics and ML model combining quantitative parameters and radiomics features extracted from simultaneous multiparametric 18F-FDG PET/MRI images can accurately discriminate between benign and malignant breast lesions.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Romeo V, Clauser P, Rasul S, et al. AI-enhanced simultaneous multiparametric 18F-FDG PET/MRI for accurate breast cancer diagnosis. Eur J Nucl Med Mol Imaging. 2021. PMID: 34374796. doi:10.1007/s00259-021-05492-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。