动态CZT-SPECT定量绝对心肌血流提高冠心病检测

Integration of quantitative absolute myocardial blood flow estimates from dynamic CZT-SPECT improves the detection of coronary artery disease.
PubMed 文献 · J Nucl Cardiol · 2021-07-08

该回顾性研究纳入32例疑似冠心病患者,评估动态CZT-SPECT定量心肌血流(MBF)与心肌血流储备(MFR)对多支冠心病的增量价值。

要点

  • MFR未找到最佳cutoff,可能与性别差异有关。

核心结论

  • 动态CZT-SPECT定量MFR的方法可行,绝对MBF对多支冠心病检测优于MFR和半定量MPI参数。

研究设计与样本

  • 回顾性纳入32例疑似冠心病患者,均行动态心电图门控双嘧达莫MPI和冠状动脉造影,间隔6个月内。

主要发现

  • 32例患者中39支狭窄血管,12例(38%)为三支病变。
  • 患者水平全局SSS升高和MBF受损与显著CAD相关,SDS和MFR不相关。
  • 血管水平区域SSS升高及MBFs、MBFr降低与狭窄血管相关。

关键数值与推荐

  • MFR未找到最佳cutoff值。

临床怎么用

  • 对疑似冠心病患者,动态CZT-SPECT定量绝对MBF可提高多支病变检出。
  • 解读时优先关注负荷后MBF绝对值,而非仅依赖MFR或半定量评分。

局限性

  • 回顾性研究,样本量小(32例患者、39支血管)。
  • MFR未找到最佳cutoff,且存在性别差异影响MFR显著性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Balanced ischemia with multi-vessel coronary artery disease (CAD) is difficult to diagnose with semiquantitative single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Dynamic cardiac SPECT provides quantitative estimations of stenosis severity and ischemic burden by assessing myocardial flow reserve (MFR) and myocardial blood flow (MBF). The aim of this study was to evaluate the incremental value of dynamic SPECT in multi-vessel coronary artery disease (CAD). METHODS: Patients with suspected CAD who underwent dynamic ECG-gated dipyridamole MPI and coronary angiography within 6 months were retrospectively reviewed. The performance of summed stress, rest and difference scores (SSS, SRS, SDS), post-stress and resting MBF (MBFs, MBFr) and MFR were compared at both patient level and vessel level. RESULTS: In 32 patients with 39 stenotic vessels, 12 had three-vessel disease (38%). Globally increased SSS and impaired MBF values were significantly associated with significant CAD at the patient level, but SDS and MFR were not. Regional increases in SSS and reductions in both MBFs and MBFr were significantly associated with stenotic vessels. The best cutoff value of global MBFs to predict CAD was 3.5 ml·g-1·min-1 (area under the curve, AUC = .84, P = .002). The best cutoff value of regional MBFs to detect significant stenosis was 3.6 ml·g-1·min-1 (AUC = .74, P < .001). However, the best possible cut-off values of MFR were not found. Sex-difference in both global and regional MBFr but MBFs was found, which might result in the non-significance in MFR. CONCLUSIONS: This study validated a clinically available method to quantify MFR using dynamic CZT-SPECT. This method improved the detectability of multi-vessel CAD, and absolute MBFs was superior to MFR and other semiquantitative MPI parameters.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Liu FS, Wang SY, Shiau YC, et al. Integration of quantitative absolute myocardial blood flow estimates from dynamic CZT-SPECT improves the detection of coronary artery disease. J Nucl Cardiol. 2021. PMID: 34240342. doi:10.1007/s12350-021-02713-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。