文献速递心脏核医学

门控99mTc-tetrofosmin SPECT与门控18F-FDG PET用QGS评估左室机械性收缩不同步的比较研究

The assessment of left ventricular mechanical dyssynchrony from gated 99mTc-tetrofosmin SPECT and gated 18F-FDG PET by QGS: a comparative study.
PubMed 文献 · J Nucl Cardiol · 2021-07-19

本研究用QGS软件分析93例患者的门控MPS与门控FDG PET数据,比较BW、Phase SD和Entropy评估左室机械性收缩不同步(LVMD)的表现。结果显示BW与Phase SD在两种方法间差异显著,Entropy无显著差异且线性相关高;以SPECT为参考标准,PET识别不同步的一致性仅为中等,Entropy是预测不同步的最佳单一PET参数,截断点为62%。结论认为两种方法均可评估LVMD但不可互换,因缺乏外部金标准,参考范围与截断值难以确立,需进一步前瞻性研究。

要点

  • 门控MPS与门控FDG PET的BW和Phase SD差异显著,Entropy无显著差异且相关性高。
  • 以SPECT为参考,PET识别LVMD的两种方法间一致性仅为中等。
  • Entropy是预测LVMD的最佳单一PET参数,截断点为62%。

核心结论

  • 门控MPS与门控FDG PET均可评估左室机械性收缩不同步,但两种方法不能互换使用。
  • 由于缺乏外部金标准,建立参考范围和截断值困难,需进一步前瞻性研究。

研究设计与样本

  • 研究分析了93例患者的门控MPS与门控FDG PET数据集,使用QGS软件计算BW、Phase SD和Entropy并进行方法间比较。
  • 以门控SPECT作为参考标准评估门控PET识别不同步的表现,并采用ROC分析确定最佳判别参数及截断值。

主要发现

  • BW和Phase SD在SPECT与PET之间差异显著。
  • Entropy在两种方法间无显著差异,且呈高线性相关。
  • SPECT与PET识别不同步的一致性仅为中等。
  • Entropy是预测不同步的最佳单一PET参数,截断点为62%。

关键数值与推荐

  • Entropy预测不同步的PET截断点为62%。

临床怎么用

  • 门控MPS与门控FDG PET均可用于评估LVMD,但结果不可直接互换,解读时应结合所用方法。
  • 以SPECT为参考时,PET识别不同步的一致性中等,提示需谨慎对待两种方法间的结果转换。

局限性

  • 缺乏外部金标准,导致参考范围和截断值难以确立。
  • SPECT与PET识别不同步的一致性仅为中等。
  • 研究为回顾性比较,需进一步前瞻性研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Due to partly conflicting studies, further research is warranted with the QGS software package, with regard to the performance of gated FDG PET phase analysis as compared to gated MPS as well as the establishment of possible cut-off values for FDG PET to define dyssynchrony. METHODS: Gated MPS and gated FDG PET datasets of 93 patients were analyzed with the QGS software. BW, Phase SD, and Entropy were calculated and compared between the methods. The performance of gated PET to identify dyssynchrony was measured against SPECT as reference standard. ROC analysis was performed to identify the best discriminator of dyssynchrony and to define cut-off values. RESULTS: BW and Phase SD differed significantly between the SPECT and PET. There was no significant difference in Entropy with a high linear correlation between methods. There was only moderate agreement between SPECT and PET to identify dyssynchrony. Entropy was the best single PET parameter to predict dyssynchrony with a cut-off point at 62%. CONCLUSION: Gated MPS and gated FDG PET can assess LVMD. The methods cannot be used interchangeably. Establishing reference ranges and cut-off values is difficult due to the lack of an external gold standard. Further prospective research is necessary.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Lehner S, Graner FP, Fischer M, et al. The assessment of left ventricular mechanical dyssynchrony from gated 99mTc-tetrofosmin SPECT and gated 18F-FDG PET by QGS: a comparative study. J Nucl Cardiol. 2021. PMID: 34282536. doi:10.1007/s12350-021-02737-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。