生化复发前列腺癌患者[68Ga]Ga-PSMA-11药代动力学研究:检测率、时间分布差异与按组织类型的动力学建模
该回顾性研究分析了142例生化复发前列腺癌患者的动态PET-CT,总体检测率为70.42%,PSA>0.4 ng/mL时为76.67%。所有肿瘤病灶SUV在前7-8分钟上升最陡,之后不同程度下降;骨转移灶的下降最陡且动力学参数低于淋巴结转移。动态显像显示前10分钟肿瘤摄取高而膀胱无活性,有助于鉴别局部复发。
要点
- 总体检测率70.42%,PSA>0.4 ng/mL者76.67%,PSA 0.51-0.99 ng/mL者57%。
- 所有肿瘤病灶SUV在前7-8分钟上升最陡,骨转移灶之后下降最陡。
- 前10分钟肿瘤摄取高且膀胱无活性,有助于鉴别局部复发。
核心结论
- 动态PET-CT显示[68Ga]Ga-PSMA-11在所有肿瘤病灶中前7-8分钟SUV上升最陡,骨转移灶之后下降最陡且动力学参数低于淋巴结转移。
- 即使PSA在0.51-0.99 ng/mL之间,检测率仍为57%。
研究设计与样本
- 回顾性分析142例生化复发前列腺癌患者的下腹部动态PET-CT及注射后80-90分钟全身静态PET-CT。
- 计算肿瘤病灶与正常组织的平均时间-活性曲线,采用三室模型和非房室模型计算肿瘤动力学。
主要发现
- 总体检测率为70.42%,PSA>0.4 ng/mL患者为76.67%,PSA 0.51-0.99 ng/mL患者为57%。
- 所有肿瘤病灶SUV在前7-8分钟上升最陡,之后不同程度下降;正常组织摄取低,膀胱在注射后15-16分钟活性累积最陡。
- 骨转移灶SUV在60和80-90分钟显著低于淋巴结转移灶,其血液转运速率、示踪剂结合及内化速率更低。
- 骨转移灶的异质性(分形维数)和血管密度显著更低。
临床怎么用
- 动态PET-CT前10分钟肿瘤摄取高而膀胱无活性,可辅助鉴别局部复发。
- 动力学建模可按组织类型提供肿瘤表征的额外信息。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: [68 Ga]Ga-PSMA-11 is a promising radiopharmaceutical for detecting tumour lesions in prostate cancer, but knowledge of the pharmacokinetics is limited. Dynamic PET-CT was performed to investigate the tumour detection and differences in temporal distribution, as well as in kinetic modelling of [68 Ga]Ga-PSMA-11 by tissue type. METHODS: Dynamic PET-CT over the lower abdomen and static whole-body PET-CT 80-90 min p.i. from 142 patients with biochemical recurrence were retrospectively analysed. Detection rates were compared to PSA levels. Average time-activity curves were calculated from tumour lesions and normal tissue. A three-compartment model and non-compartment model were used to calculate tumour kinetics. RESULTS: Overall detection rate was 70.42%, and in patients with PSA > 0.4 ng/mL 76.67%. All tumour lesions presented the steepest standardised uptake value (SUV) incline in the first 7-8 min before decreasing to different degrees. Normal tissue presented with a low uptake, except for the bladder, which accumulated activity the steepest 15-16 min. p.i.. While all tumour lesions continuously increased, bone metastases showed the steepest decline, resulting in a significantly lower SUV than lymph node metastases (60 and 80-90 min). Transport rate from the blood and tracer binding and internalisation rate were lower in bone metastases. Heterogeneity (fractal dimension) and vascular density were significantly lower in bone metastases. CONCLUSION: Even at low PSA between 0.51 and 0.99 ng/mL, detection rate was 57%. Dynamic imaging showed a time window in the first 10 min where tumour uptake is high, but no bladder activity is measured, aiding accuracy in distinction of local recurrence. Kinetic modelling provided additional information for tumour characterisation by tissue type.
引用
- Strauss DS, Sachpekidis C, Kopka K, et al. Pharmacokinetic studies of [68 Ga]Ga-PSMA-11 in patients with biochemical recurrence of prostate cancer: detection, differences in temporal distribution and kinetic modelling by tissue type. Eur J Nucl Med Mol Imaging. 2021. PMID: 34110436. doi:10.1007/s00259-021-05420-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。