11C-胆碱PET/CT在原发性甲状旁腺功能亢进症一线影像阴性或不一致后的诊断效能
本研究回顾性纳入2015至2019年间36例原发性甲状旁腺功能亢进症患者,均在一线影像阴性或不一致后接受11C-胆碱PET/CT并后续手术。以手术探查和病理为金标准,病灶水平灵敏度97%、阳性预测值95%、准确率94%,支持其作为后续定位手段。
要点
- 一线影像阴性或不一致时,11C-胆碱PET/CT病灶水平灵敏度达97%。
- 该检查病灶水平阳性预测值95%、准确率94%。
- 34/36例(94%)患者据此完成聚焦性甲状旁腺切除术。
核心结论
- 对一线影像阴性或不一致的原发性甲状旁腺功能亢进症患者,11C-胆碱PET/CT能以高灵敏度和准确率定位病理甲状旁腺。
研究设计与样本
- 回顾性单中心队列研究,纳入2015至2019年间一线影像阴性或不一致后行11C-胆碱PET/CT并接受甲状旁腺手术的36例原发性甲状旁腺功能亢进症患者。
主要发现
- 36例患者中11C-胆碱PET/CT识别40个病灶,手术切除37个甲状旁腺病灶。
- 34/36例(94%)患者行聚焦性甲状旁腺切除术,1例因异位腺瘤行颈部探查,1例因双腺瘤行双侧探查。
- 病灶水平灵敏度97%、阳性预测值95%、准确率94%。
关键数值与推荐
- 以手术探查和病理组织学检查为金标准,病灶水平评估11C-胆碱PET/CT诊断效能。
临床怎么用
- 对一线影像阴性或不一致的原发性甲状旁腺功能亢进症患者,可考虑将11C-胆碱PET/CT作为后续定位检查以指导手术。
局限性
- 回顾性单中心设计,样本量36例,其中3例已知多发性内分泌腺瘤病综合征。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Identifying the correct location of a parathyroid adenoma in patients with primary hyperparathyroidism (pHPT) is crucial as it can guide surgical treatment. This study aimed to determine the diagnostic performance of 11C-choline PET/CT in patients with pHPT as a next in-line scan after primary negative or discordant first-line imaging. METHODS: This was a retrospective single-center cohort study. All patients with pHPT that were scanned utilizing 11C-choline PET/CT, after prior negative or discordant imaging, between 2015 and 2019 and who subsequently underwent parathyroid surgery were included. The results of the 11C-choline PET/CT were evaluated lesion-based, with surgical exploration and histopathological examination as the gold standard. RESULTS: In total, 36 patients were included of which three patients were known to have Multiple Endocrine Neoplasia (MEN) syndrome. In these 36 patients, 40 lesions were identified on 11C-choline PET/CT and 37 parathyroid lesions were surgically removed. In 34/36 (94%) patients a focused parathyroidectomy was performed, in one patient a cervical exploration due to an ectopically identified adenoma, and in one patient a bilateral exploration was performed because of a double adenoma. Overall, per-lesion sensitivity of 11C-choline PET/CT was 97%, the positive predictive value was 95% and the accuracy was 94% for all parathyroid lesions. CONCLUSIONS: In patients with pHPT and prior negative or discordant first-line imaging results, pathological parathyroid glands can be localized by 11C-choline PET/CT with high sensitivity and accuracy.
引用
- Noltes ME, Kruijff S, Jansen L, et al. A retrospective analysis of the diagnostic performance of 11C-choline PET/CT for detection of hyperfunctioning parathyroid glands after prior negative or discordant imaging in primary hyperparathyroidism. EJNMMI Res. 2021. PMID: 33770255. doi:10.1186/s13550-021-00778-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。