文献速递心脏核医学

18F-FDG PET量化的整体与区域心功能障碍可预测ICD患者室性心律失常

Global and regional cardiac dysfunction quantified by 18F-FDG PET scans can predict ventricular arrhythmia in patients with implantable cardioverter defibrillator.
PubMed 文献 · J Nucl Cardiol · 2021-03-09

一项前瞻性观察研究纳入51例需植入ICD的患者,术前行18F-FDG PET扫描并随访室性心律失常(VA)发生。17例(33.3%)发生VA,VA患者瘢痕面积、相位标准差、带宽、总增厚评分和总运动评分均显著更大。Cox回归和ROC分析显示瘢痕大小、不同步和总增厚评分与VA发生相关(HR 4.956,95%CI 1.70-14.46)。

要点

  • 18F-FDG PET量化的左室瘢痕负荷、不同步和总增厚评分与ICD术后VA发生相关。
  • VA患者瘢痕面积、相位标准差、带宽、总增厚评分和总运动评分均显著高于无VA患者。
  • 瘢痕大小、不同步和总增厚评分与VA发生的HR为4.956(95%CI 1.70-14.46)。

核心结论

  • 18F-FDG PET量化的较大左室瘢痕负荷、增加的不同步和较高的总增厚评分可能提示ICD植入后更高的VA发生率。

研究设计与样本

  • 前瞻性观察研究,招募需植入ICD的患者,术前行18F-FDG PET扫描并随访VA发生,分析影像结果与VA的关联。
  • 共分析51例患者(33例男性,年龄53.9±17.2岁)。

主要发现

  • 51例中17例(33.3%)发生VA。
  • VA患者瘢痕面积为17.7±12.4%,无VA患者为7.0±7.9%。
  • VA患者相位标准差为51.4°±14.0°,无VA患者为34.0°±15.0°。
  • VA患者带宽为172.9°±39.8°,无VA患者为128.7°±49.9°。
  • VA患者总增厚评分为29.5±11.1,无VA患者为17.8±13.2;总运动评分为42.9±11.5,无VA患者为33.0±19.0。

关键数值与推荐

  • Cox回归和ROC分析显示瘢痕大小、不同步和总增厚评分与VA发生相关,HR为4.956(95%CI 1.70-14.46)。

临床怎么用

  • 对需植入ICD的患者,术前18F-FDG PET量化的瘢痕负荷、不同步和总增厚评分可能有助于识别VA高风险者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: A low appropriate therapy rate indicates that a minority of patients will benefit from their implantable cardioverter defibrillator (ICD). Quantitative measurements from 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) may predict ventricular arrhythmia (VA) occurrence after ICD placement. METHODS: We performed a prospective observational study and recruited patients who required ICD placement. Pre-procedure image scans were performed. Patients were followed up for VA occurrence. Associations between image results and VA were analyzed. RESULTS: In 51 patients (33 males, 53.9 ± 17.2 years) analyzed, 17 (33.3%) developed VA. Compared with patients without VA, patients with VA had significantly larger values in scar area (17.7 ± 12.4% vs. 7.0 ± 7.9%), phase standard deviation (51.4° ± 14.0° vs. 34.0° ± 15.0°), bandwidth (172.9° ± 39.8° vs. 128.7° ± 49.9°), sum thickening score (STS, 29.5 ± 11.1 vs. 17.8 ± 13.2), and sum motion score (42.9 ± 11.5 vs. 33.0 ± 19.0). Cox regression analysis and receiver operating characteristic curve analysis showed that scar size, dyssynchrony, and STS were associated with VA occurrence (HR, 4.956, 95% CI 1.70-14.46). CONCLUSION: Larger left ventricular scar burden, increased dyssynchrony, and higher STS quantified by 18F-FDG PET may indicate a higher VA incidence after ICD placement.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Jing R, Sun XX, Hua W, et al. Global and regional cardiac dysfunction quantified by 18F-FDG PET scans can predict ventricular arrhythmia in patients with implantable cardioverter defibrillator. J Nucl Cardiol. 2021. PMID: 33751472. doi:10.1007/s12350-020-02515-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。