文献速递心脏核医学肿瘤 PET/CT

补救方案改善18F-FDG PET/CT心肌代谢显像图像质量

Rescue Protocol to Improve the Image Quality of 18F-FDG PET/CT Myocardial Metabolic Imaging.
PubMed 文献 · Clin Nucl Med · 2021-01-01

补救后图像视觉分级显著改善(P < 0.001),心肌与本底血池活性比(M/B)由1.6 ± 0.6升至3.4 ± 1.4(P < 0.001),提示该方案可快速改善图像质量。

要点

  • 对初次心肌18F-FDG显像质量差的患者,补救方案可快速提升图像可判读性。
  • 补救后86.3%患者达到3级(摄取良好),初次显像无3级病例。
  • 补救后M/B由1.6 ± 0.6升至3.4 ± 1.4,差异有统计学意义。

核心结论

  • 补救方案(再次注射低剂量18F-FDG并同时给予1至2 U胰岛素及口服10 g葡萄糖)可成功且快速地改善心肌18F-FDG代谢显像图像质量。

主要发现

  • 初次显像视觉分级0级24例(47%)、1级27例(53%)、2级0例、3级0例;补救显像0级0例、1级3例(5.9%)、2级4例(7.8%)、3级44例(86.3%)(P < 0.001)。
  • 补救后M/B显著高于初次(3.4 ± 1.4 vs 1.6 ± 0.6,P < 0.001)。

关键数值与推荐

  • 视觉分级标准:0级为均匀、极低摄取;1级以极低或轻度摄取为主;2级为中度摄取;3级为摄取良好。
  • 补救方案组成:再次注射低剂量18F-FDG,同时注射1至2 U胰岛素并口服10 g葡萄糖;补救采集于初次采集后1小时进行。

临床怎么用

  • 对初次心肌18F-FDG代谢显像图像质量差或无法判读的患者,可考虑采用该补救方案再次显像以改善图像质量,便于存活心肌评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: 18F-FDG PET myocardial metabolic imaging is used to estimate myocardial viability. However, poor image quality can affect the accurate quantification of viable myocardium. We assessed the feasibility of a rescue protocol that reinjected low-dose 18F-FDG with simultaneous 1 to 2 U of insulin injection and oral administration of 10 g of glucose to improve the image quality of 18F-FDG PET myocardial metabolic imaging. PATIENTS AND METHODS: Fifty-one consecutive patients with poor quality to uninterpretable 18F-FDG PET/CT myocardial metabolic images received the rescue protocol immediately after the initial image acquisition. The postrescue image acquisition was performed 1 hour later. The rescue image quality was compared with the initial image. The qualitative visual estimation of the images was graded as follows: grade 0, homogeneous, minimal uptake; grade 1, predominantly minimal or mild uptake; grade 2, moderate uptake; and grade 3, good uptake. The myocardium-to-blood pool activity ratio (M/B) was measured to assess the image quality quantitatively. RESULTS: The grades of 0 to 3 were observed in 24 (47%), 27 (53%), 0 (0%), and 0 (0%) patients, respectively, for the initial imaging, and in 0 (0%), 3 (5.9%), 4 (7.8%), and 44 (86.3%) patients for the rescue imaging (P < 0.001). The rescue M/B was significantly higher than the initial M/B (3.4 ± 1.4 vs 1.6 ± 0.6, respectively; P < 0.001). CONCLUSIONS: The rescue protocol successfully and rapidly improved the quality of myocardial 18F-FDG metabolic imaging.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Sun XX, Li S, Wang Y, et al. Rescue Protocol to Improve the Image Quality of 18F-FDG PET/CT Myocardial Metabolic Imaging. Clin Nucl Med. 2021. PMID: 33661201. doi:10.1097/RLU.0000000000003572

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。