文献速递神经核医学肿瘤 PET/CT

深度学习去除非特异性摄取改进淀粉样蛋白负荷定量

Improved amyloid burden quantification with nonspecific estimates using deep learning.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2021-01-07

本研究利用配对MR和PET图像训练卷积神经网络(CNN)和条件生成对抗网络(cGAN),从结构MR预测非特异性(NS)PET估计,并从SUVr中减去以得到特异性淀粉样负荷(SAβL)。在172名不同脑血管病(CeVD)严重程度的参与者中,多模态ScaleNet预测皮层灰质NS内容的平均相对误差低于2%,且SAβL与认知和功能测试评分的关联比SUVr提高最多67%。结论认为深度学习去除非特异性摄取可提高淀粉样负荷测量的准确性。

要点

  • 多模态ScaleNet预测皮层灰质NS内容平均相对误差低于2%。
  • SAβL与认知和功能测试评分的关联比SUVr提高最多67%。
  • 去除非特异性摄取可提高淀粉样负荷测量准确性。

核心结论

  • 利用深度学习从淀粉样PET负荷测量中去除不良非特异性摄取是可行的,并大幅提高其准确性。

研究设计与样本

  • 从新加坡一项涉及172名不同CeVD严重程度参与者的淀粉样PET研究中,选择显示极低特异性摄取的配对MR和PET图像。
  • 训练两个卷积神经网络(ScaleNet和HighRes3DNet)和一个条件生成对抗网络(cGAN),将结构MR映射到NS PET图像。

主要发现

  • 多模态ScaleNet在预测皮层灰质NS内容方面优于其他网络,平均相对误差低于2%。
  • 与SUVr相比,SAβL与认知和功能测试评分的关联增加最多67%。

临床怎么用

  • 该新型分析流程可去除淀粉样PET定量中的非特异性摄取变异,提高与认知功能评分的关联性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Standardized uptake value ratio (SUVr) used to quantify amyloid-β burden from amyloid-PET scans can be biased by variations in the tracer's nonspecific (NS) binding caused by the presence of cerebrovascular disease (CeVD). In this work, we propose a novel amyloid-PET quantification approach that harnesses the intermodal image translation capability of convolutional networks to remove this undesirable source of variability. METHODS: Paired MR and PET images exhibiting very low specific uptake were selected from a Singaporean amyloid-PET study involving 172 participants with different severities of CeVD. Two convolutional neural networks (CNN), ScaleNet and HighRes3DNet, and one conditional generative adversarial network (cGAN) were trained to map structural MR to NS PET images. NS estimates generated for all subjects using the most promising network were then subtracted from SUVr images to determine specific amyloid load only (SAβL). Associations of SAβL with various cognitive and functional test scores were then computed and compared to results using conventional SUVr. RESULTS: Multimodal ScaleNet outperformed other networks in predicting the NS content in cortical gray matter with a mean relative error below 2%. Compared to SUVr, SAβL showed increased association with cognitive and functional test scores by up to 67%. CONCLUSION: Removing the undesirable NS uptake from the amyloid load measurement is possible using deep learning and substantially improves its accuracy. This novel analysis approach opens a new window of opportunity for improved data modeling in Alzheimer's disease and for other neurodegenerative diseases that utilize PET imaging.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Liu H, Nai YH, Saridin F, et al. Improved amyloid burden quantification with nonspecific estimates using deep learning. Eur J Nucl Med Mol Imaging. 2021. PMID: 33415430. doi:10.1007/s00259-020-05131-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。