三维运动补偿[18F]NaF PET/MR冠状动脉斑块成像
本研究将基于MR的运动补偿框架应用于[18F]NaF PET数据,在10例患者中生成高分辨率运动补偿PET和MR图像。结果显示斑块靶本比提高7±7%,对比本底比提高26±38%,斑块直径减小22±18%,动态衰减校正可减少衰减校正伪影。
要点
- MR运动模型成功补偿PET和MR中的生理运动。
- 斑块靶本比提高7±7%,对比本底比提高26±38%。
- 斑块直径减小22±18%,动态衰减校正减少伪影。
核心结论
- 基于MR的运动校正框架可改善冠状动脉系统局灶性示踪剂热点的靶本比、对比本底比和宽度。
- 动态衰减校正可有效降低冠状动脉肺-软组织边界处衰减校正伪影的风险,有望实现更可重复和可靠的斑块定位。
研究设计与样本
- 采集自由呼吸三维Dixon MR数据,回顾性分箱为多个呼吸和心脏运动状态,并使用基于模型的重建框架分离脂肪和水成分。
- 从动态MR重建中生成非刚性心肺运动模型和运动分辨衰减图,应用于PET数据以改善图像质量。
- 该方法在10例患者中 tested,评估局灶性示踪剂热点的靶本比、对比本底比和直径。
主要发现
- MR运动模型成功应用于补偿PET和MR中的生理运动。
- 识别斑块的靶本比提高7±7%,对比本底比提高26±38%,斑块直径减小22±18%。
- 基于MR的动态衰减校正强烈减少衰减校正伪影,且不受 underlying MR重建中支架相关信号空洞的影响。
临床怎么用
- 该运动补偿框架可应用于[18F]NaF PET/MR冠状动脉斑块成像,提高图像质量和斑块定位的可重复性。
- 动态衰减校正有助于减少冠状动脉肺-软组织边界处的衰减校正伪影。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Cardiac PET has recently found novel applications in coronary atherosclerosis imaging using [18F]NaF as a radiotracer, highlighting vulnerable plaques. However, the resulting uptakes are relatively small, and cardiac motion and respiration-induced movement of the heart can impair the reconstructed images due to motion blurring and attenuation correction mismatches. This study aimed to apply an MR-based motion compensation framework to [18F]NaF data yielding high-resolution motion-compensated PET and MR images. METHODS: Free-breathing 3-dimensional Dixon MR data were acquired, retrospectively binned into multiple respiratory and cardiac motion states, and split into fat and water fraction using a model-based reconstruction framework. From the dynamic MR reconstructions, both a non-rigid cardiorespiratory motion model and a motion-resolved attenuation map were generated and applied to the PET data to improve image quality. The approach was tested in 10 patients and focal tracer hotspots were evaluated concerning their target-to-background ratio, contrast-to-background ratio, and their diameter. RESULTS: MR-based motion models were successfully applied to compensate for physiological motion in both PET and MR. Target-to-background ratios of identified plaques improved by 7 ± 7%, contrast-to-background ratios by 26 ± 38%, and the plaque diameter decreased by -22 ± 18%. MR-based dynamic attenuation correction strongly reduced attenuation correction artefacts and was not affected by stent-related signal voids in the underlying MR reconstructions. CONCLUSIONS: The MR-based motion correction framework presented here can improve the target-to-background, contrast-to-background, and width of focal tracer hotspots in the coronary system. The dynamic attenuation correction could effectively mitigate the risk of attenuation correction artefacts in the coronaries at the lung-soft tissue boundary. In combination, this could enable a more reproducible and reliable plaque localisation.
引用
- Mayer J, Wurster TH, Schaeffter T, et al. Imaging coronary plaques using 3D motion-compensated [18F]NaF PET/MR. Eur J Nucl Med Mol Imaging. 2021. PMID: 33474584. doi:10.1007/s00259-020-05180-4