深度学习提升负荷心肌灌注SPECT诊断准确性
该研究基于耶鲁纽黑文医院37243例负荷心肌灌注SPECT患者,开发深度学习卷积神经网络(CNN)自动诊断心肌灌注异常,并与传统定量灌注缺损大小(DS)法比较。结果显示深度学习法AUC显著高于DS法(0.872±0.002 vs. 0.838±0.003,p<0.01),在八个亚组中诊断准确性和特异性更高、一致性更好,但敏感性略低。
要点
- 深度学习法诊断心肌灌注异常的AUC为0.872±0.002,显著高于DS法的0.838±0.003。
- 八个亚组中深度学习法准确性82.7%±2.5%、特异性84.9%±3.7%,均高于DS法。
- 深度学习法敏感性74.4%±4.2%,略低于DS法的79.8%±5.8%。
核心结论
- 深度学习用于负荷心肌灌注SPECT可提高心肌灌注异常诊断的准确性和一致性。
研究设计与样本
- 回顾性纳入耶鲁纽黑文医院37243例(男性51.5%)接受负荷99mTc-Tetrofosmin或99mTc-Sestamibi MPI的患者,按临床核心脏病专家最终诊断分为正常(75.4%)与异常(24.6%)。
- 基于SPECT MPI的圆周计数剖面图训练深度CNN,采用5折交叉验证评估,每折训练、验证和测试集分别为27933、1862和7448例。
主要发现
- 深度学习法AUC显著高于DS法(0.872±0.002 vs. 0.838±0.003,p<0.01)。
- 八个亚组中深度学习法AUC为0.865±0.010,DS法为0.838±0.019,深度学习法标准差更小、一致性更好。
- 八个亚组中深度学习法准确性82.7%±2.5%、特异性84.9%±3.7%,DS法分别为78.5%±3.6%和77.5%±6.5%。
- 八个亚组中深度学习法敏感性74.4%±4.2%,低于DS法的79.8%±5.8%。
临床怎么用
- 负荷心肌灌注SPECT可借助深度学习CNN辅助自动诊断心肌灌注异常,提高诊断准确性与跨亚组一致性。
- 深度学习法特异性较高但敏感性略低,临床解读时需结合其他信息综合判断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Deep convolutional neural networks (CNN) for single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) has been used to improve the diagnostic accuracy of coronary artery disease (CAD). This study was to design and evaluate a deep learning (DL) approach to automatic diagnosis of myocardial perfusion abnormalities from stress-only MPI. METHODS: The new DL approach developed for this study was compared to a conventional quantitative perfusion defect size (DS) method. A total of 37,243 patients (51.5% males) undergone stress 99mTc-Tetrofosmin or 99mTc-Sestamibi MPI were selected retrospectively from Yale New Haven Hospital. Patients were dichotomized as studies with normal (75.4%) or abnormal (24.6%) myocardial perfusion based on final diagnoses of clinical nuclear cardiologists. Stress myocardial perfusion defect size was calculated using Yale quantitative analytic software. A deep CNN was trained using the circumferential count profile maps derived from SPECT MPI and was evaluated for the diagnosis of perfusion abnormality with a 5-fold cross-validation approach. In each fold, 27,933, 1862 and 7448 patients were used as training, validation and testing datasets, respectively. The area under the receiver-operating characteristic curve (AUC) was calculated and analyzed for all patients as well as for the eight sub-groups classified based on patient genders, quantitative algorithms, radioactive tracers and SPECT cameras. RESULTS: The AUC value resulted from the DL method was significantly higher than that from the DS method (0.872 ± 0.002 vs. 0.838 ± 0.003, p < 0.01). Across the eight sub-groups, the DL method provided more consistent AUC values in terms of smaller standard deviation and higher diagnostic accuracy and specificity, but slightly lower sensitivity than the DS method (AUC: 0.865 ± 0.010 vs. 0.838 ± 0.019, Accuracy: 82.7% ± 2.5% vs. 78.5% ± 3.6%, Specificity: 84.9% ± 3.7% vs. 77.5% ± 6.5%, Sensitivity: 74.4% ± 4.2% vs. 79.8% ± 5.8%). CONCLUSIONS: The incorporation of deep learning for stress-only MPI has a considerable potential to improve the diagnostic accuracy and consistency in the detection of myocardial perfusion abnormalities.
引用
- Liu H, Wu J, Miller EJ, et al. Diagnostic accuracy of stress-only myocardial perfusion SPECT improved by deep learning. Eur J Nucl Med Mol Imaging. 2021. PMID: 33511425. doi:10.1007/s00259-021-05202-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。