PET-IVIM MRI联合预测无淋巴结转移宫颈癌脉管间隙浸润的价值
本研究纳入90例PET/MRI未见淋巴结转移征象的宫颈癌患者,按术后病理分为LVSI阳性组25例和阴性组65例,评估PET代谢参数与IVIM MRI参数对LVSI的预测价值。结果显示TLG与Dmin联合预测LVSI的AUC为0.861,灵敏度80.00、特异度86.15(P<0.001),验证模型AUC为0.878。
要点
- TLG与Dmin联合是预测无淋巴结转移宫颈癌LVSI的最佳指标,AUC 0.861。
- Dmin和TLG最佳截断值分别为0.58×10-3 mm2/s和66.68 g/cm3。
- PET代谢参数与IVIM参数在LVSI阳性与阴性组间存在显著差异。
核心结论
- TLG与Dmin联合可能是预测无淋巴结转移宫颈癌LVSI的最佳指标。
研究设计与样本
- 回顾性纳入90例PET/MRI未见淋巴结转移征象的宫颈癌患者,按术后病理分为LVSI阳性25例和阴性65例。
- 采用Student t检验或Mann-Whitney U检验比较两组PET与IVIM参数,并用ROC曲线、单因素及多因素logistic回归分析。
- 通过1000次bootstrap抽样建立控制模型,并用校准曲线和ROC曲线验证性能。
主要发现
- PET参数SUVmax、SUVmean、MTV、TLG及IVIM参数Dmin、ADCmin、GTV在LVSI阳性与阴性组间差异显著(P<0.05)。
- TLG与Dmin联合预测LVSI的AUC为0.861,灵敏度80.00,特异度86.15(P<0.001)。
- 验证模型显示TLG与Dmin联合预测价值最强,AUC为0.878,校准曲线显示一致性良好。
关键数值与推荐
- Dmin最佳截断值为0.58×10-3 mm2/s,TLG最佳截断值为66.68 g/cm3(以约登指数最大确定)。
临床怎么用
- 对于PET/MRI未见淋巴结转移的宫颈癌患者,可联合TLG与Dmin评估LVSI风险,辅助治疗决策。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the contributory value of positron emission tomography (PET)-intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) in the prediction of lymphovascular space invasion (LVSI) in patients with cervical cancer without lymphatic metastasis. MATERIALS AND METHODS: A total of 90 patients with cervical cancer without signs of lymph node metastasis on PET/MRI were enrolled in this study. The tumours were classified into LVSI-positive (n = 25) and LVSI-negative (n = 65) groups according to postoperative pathology. The PET-derived parameters (SUVmax, SUVmean, metabolic tumour volume (MTV) and total lesion glycolysis (TLG)) and IVIM-derived parameters (ADCmean, ADCmin, Dmean, Dmin, f, D* and gross tumour volume (GTV)) between the two groups were evaluated using a Student's t test (Mann-Whitney U test for variables with a nonnormal distribution) and receiver operating characteristic (ROC) curves. The optimal combination of PET/MR parameters for predicting LVSI was investigated using univariate and multivariate logistic regression models and evaluated by ROC curves. The optimal cutoff threshold values corresponded to the maximal values of the Youden index. A control model was established using 1000 bootstrapped samples, for which the performance was validated using calibration curves and ROC curves. RESULTS: PET-derived parameters (SUVmax, SUVmean, MTV, TLG) and IVIM MRI-derived parameters (Dmin, ADCmin, GTV) were significantly different between patients with and without LVSI (P < 0.05). Logistic analyses showed that a combination of TLG and Dmin had the strongest predictive value for LVSI diagnosis (area under the curve (AUC), 0.861; sensitivity, 80.00; specificity, 86.15; P < 0.001). The optimal cutoff threshold values for Dmin and TLG were 0.58 × 10-3 mm2/s and 66.68 g/cm3, respectively. The verification model showed the combination of TLG and Dmin had the strongest predictive value, and its ROC curve and calibration curve showed good accuracy (AUC, 0.878) and consistency. CONCLUSIONS: The combination of TLG and Dmin may be the best indicator for predicting LVSI in cervical cancer without lymphatic metastasis.
引用
- Xu C, Yu Y, Li X, et al. Value of integrated PET-IVIM MRI in predicting lymphovascular space invasion in cervical cancer without lymphatic metastasis. Eur J Nucl Med Mol Imaging. 2021. PMID: 33506309. doi:10.1007/s00259-021-05208-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。