文献速递神经核医学肿瘤 PET/CT

FDG-PET联合CTA评估不明原因缺血性卒中患者的非狭窄性颈动脉斑块

Evaluation of non-stenotic carotid atherosclerotic plaques with combined FDG-PET imaging and CT angiography in patients with ischemic stroke of unknown origin.
PubMed 文献 · J Nucl Cardiol · 2021-01-18

本研究回顾性纳入44例隐源性缺血性卒中患者,在卒中后7±8天行颈动脉CTA与FDG-PET成像。结果显示,卒中同侧颈动脉非狭窄斑块的FDG摄取(TBR 2.24±0.80 vs 1.84±0.50)及低密度斑块比例(41% vs 11%)均高于对侧,提示FDG-PET-CTA可识别与卒中相关的高危非狭窄斑块。

要点

  • 卒中同侧颈动脉非狭窄斑块TBR高于对侧(2.24±0.80 vs 1.84±0.50,p<.05)。
  • 同侧低密度斑块比例及低密度范围均高于对侧(41% vs 11%;0.72±1.2 mm2 vs 0.13±0.43 mm2,p<.05)。
  • FDG-PET-CTA联合成像有助于判断非狭窄斑块的卒中病因作用。

核心结论

  • 在不明原因缺血性卒中伴非狭窄斑块患者中,FDG-PET-CTA显示卒中同侧高危斑块特征更常见,提示这些斑块可能具有致病作用。

研究设计与样本

  • 回顾性研究,共识别44例同时接受颈动脉CTA和FDG-PET成像的患者。
  • CTA用于识别斑块形态学特征,PET用于定量颈动脉FDG摄取强度。
  • 患者卒中后成像时间为7±8天。

主要发现

  • 卒中间侧颈动脉检出44个FDG摄取增高的非狭窄斑块,对侧检出7个。
  • FDG-PET最病变节段TBR卒中同侧高于对侧(2.24±0.80 vs 1.84±0.50;p<.05)。
  • 高FDG摄取颈动脉区域中,低密度斑块患病率同侧高于对侧(41% vs 11%;p<.05)。
  • 低密度范围同侧大于对侧(0.72±1.2 mm2 vs 0.13±0.43 mm2;p<.05)。

关键数值与推荐

  • 非狭窄斑块定义为未造成狭窄的颈动脉斑块,具体狭窄阈值原文未报告。
  • 高危斑块影像特征包括CTA低密度斑块与PET FDG摄取增高,以TBR定量。
  • 统计学显著性判定为p<.05。

临床怎么用

  • 对隐源性缺血性卒中患者,可考虑FDG-PET-CTA联合评估非狭窄颈动脉斑块的炎症与形态特征,辅助病因判断。

局限性

  • 为回顾性研究,样本量44例,可能存在选择偏倚。
  • 原文未报告随访结局、治疗决策影响及多中心验证结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Non-stenotic plaques are an underestimated cause of ischemic stroke. Imaging aspects of high-risk carotid plaques can be identified on CT angiography (CTA) and 18F-fluoro-deoxyglucose positron emission tomography (FDG-PET) imaging. We evaluated in patients with cryptogenic ischemic stroke the usefulness of FDG-PET-CTA. METHODS: 44 patients imaged with CTA and FDG-PET were identified retrospectively. Morphological features were identified on CTA. Intensity of FDG uptake in carotid arteries was quantified on PET. RESULTS: Patients were imaged 7 ± 8 days after stroke. 44 non-stenotic plaques with increased 18F-FDG uptake were identified in the carotid artery ipsilateral to stroke and 7 contralateral. Most-diseased-segment TBR on FDG-PET was higher in artery ipsilateral vs. contralateral to stroke (2.24 ± 0.80 vs. 1.84 ± 0.50; p < .05). In the carotid region with high FDG uptake, prevalence of hypodense plaques and extent of hypodensity on CTA were higher in artery ipsilateral vs. contralateral to stroke (41% vs. 11%; 0.72 ± 1.2 mm2 vs. 0.13 ± 0.43 mm2; p < .05). CONCLUSIONS: In patients with ischemic stroke of unknown origin and non-stenotic plaques, we found an increased prevalence of high-risk plaques features ipsilateral vs. contralateral to stroke on FDG-PET-CTA imaging suggesting a causal role for these plaques.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Mikail N, Meseguer E, Lavallée P, et al. Evaluation of non-stenotic carotid atherosclerotic plaques with combined FDG-PET imaging and CT angiography in patients with ischemic stroke of unknown origin. J Nucl Cardiol. 2021. PMID: 33462787. doi:10.1007/s12350-020-02511-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。