低剂量方案用于心肌灌注82Rb显像的模拟研究
本研究基于171例接受全剂量82Rb PET静息/负荷显像且有创冠状动脉造影的患者,利用全剂量列表文件重建半剂量和四分之一剂量图像,评估低剂量方案对心肌灌注定量诊断准确性的影响。结果显示半剂量方案对负荷总灌注缺损的诊断准确性无显著影响,而四分之一剂量方案准确性降低;缺血总灌注缺损在三方案间无差异。
要点
- 半剂量82Rb PET不降低负荷总灌注缺损的诊断准确性,可用于临床。
- 四分之一剂量方案降低负荷总灌注缺损的AUC,准确性受损。
- 缺血总灌注缺损的诊断准确性在半剂量和四分之一剂量方案中均无显著差异。
核心结论
- 半剂量82Rb PET显像不影响三维PET/CT系统上的定量诊断准确性,可临床使用。
研究设计与样本
- 研究纳入171例接受静息/负荷82Rb PET(三维四环PET/CT)及6个月内侵入性冠状动脉造影的患者。
- 通过全剂量列表文件按预设事件百分比重建半剂量和四分之一剂量图像。
主要发现
- 负荷总灌注缺损AUC:全剂量0.807,半剂量0.802(P=0.108),四分之一剂量0.786(P=0.037)。
- 缺血总灌注缺损AUC:全剂量0.831,半剂量0.835,四分之一剂量0.831(所有P≥0.805)。
关键数值与推荐
- 梗阻性冠状动脉疾病定义为三大冠状动脉任一狭窄至少70%。
- 患者中位体重指数28.0(四分位距23.9-31.7),注射剂量1165±189 MBq的82Rb。
临床怎么用
- 在半剂量方案下可维持82Rb PET对负荷总灌注缺损的定量诊断准确性。
- 四分之一剂量方案可能降低负荷总灌注缺损的诊断准确性。
局限性
- 低剂量图像通过全剂量列表文件重建模拟,非实际低剂量注射采集。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Quantification of myocardial perfusion and myocardial blood flow using 82Rb PET is increasingly used for assessment of coronary artery disease. Current guidelines suggest injections of 1,100-1,500 MBq for both stress and rest. Reducing the injected dose avoids PET system saturation in first-pass flow images and reduces radiation exposure, but the impact on myocardial perfusion quantification of static perfusion images is not fully understood. In this study, we aimed to evaluate the feasibility of performing myocardial perfusion scans using either a half-dose (HfD) or quarter-dose (QD) protocol using reconstructions from acquired full-dose (FD) scans. Methods: This study comprised 171 patients who underwent rest/stress 82Rb PET with a 3-dimensional 4-ring PET/CT scanner using a FD protocol and invasive coronary angiography within 6 mo of the PET emission scan. HfD and QD reconstructions were obtained using the prescribed percentage of events from the FD list-mode files. The total perfusion deficit was quantified for rest (rTPD), stress (sTPD), and ischemia (ITPD = sTPD - rTPD). Diagnostic accuracy for obstructive coronary artery disease, defined as at least 70% stenosis in any of the 3 major coronary arteries, was compared with area under the receiver-operating-characteristic curve (AUC). Results: Patients with a median body mass index of 28.0 (interquartile range, 23.9-31.7) were injected with doses of 1,165 ± 189 MBq of 82Rb. For sTPD, FD and HfD protocols had similar AUCs (FD, 0.807; HfD, 0.802; P = 0.108), whereas QD had a reduced AUC (0.786, P = 0.037). There was no difference in the AUC obtained for ITPD among the 3 protocols (FD, 0.831; HfD, 0.835; QD, 0.831; all P ≥ 0.805). Conclusion: HfD imaging does not affect the quantitative diagnostic accuracy of 82Rb PET on 3-dimensional PET/CT systems and could be used clinically.
引用
- Lassen ML, Otaki Y, Kavanagh P, et al. Simulation of Low-Dose Protocols for Myocardial Perfusion 82Rb Imaging. J Nucl Med. 2021. PMID: 33419943. doi:10.2967/jnumed.120.252429
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。