文献速递心脏核医学肿瘤 PET/CT

FDG PET/CT 在外科治疗感染性心内膜炎患者中的诊断价值:三级中心回顾性分析

Diagnostic value of FDG PET/CT imaging in patients with surgically managed infective endocarditis: results of a retrospective analysis at a tertiary center.
PubMed 文献 · J Nucl Cardiol · 2020-12-22

该回顾性分析纳入2014年1月至2018年10月一家三级IE转诊中心内符合ICD-10 IE编码且同时接受心脏手术与FDG PET/CT的住院患者,最终分析29例(28例经手术证实IE)。FDG PET/CT真阳性15例(敏感度56%),假阴性12例;Duke标准联合FDG PET/CT使确诊IE患者敏感度由79%升至89%,增益主要来自人工瓣膜心内膜炎(PVE)患者(78%升至94%),假阴性扫描者假体年龄更高。

要点

  • 手术证实IE队列中FDG PET/CT敏感度为56%,假阴性12例。
  • Duke标准联合FDG PET/CT使全部确诊IE敏感度由79%升至89%。
  • PVE患者联合后敏感度由78%升至94%,假阴性者假体年龄更高。

核心结论

  • 在手术证实IE的真实世界队列中FDG PET/CT敏感度为56%,与Duke标准联合可使PVE患者IE诊断获得16%的增益。

研究设计与样本

  • 回顾性分析2014年1月至2018年10月一家三级IE转诊中心内同时符合IE的ICD-10编码及心脏手术与FDG PET/CT的OPS编码的住院患者,最终分析29例,其中28例经手术证实IE。

主要发现

  • FDG PET/CT真阳性15例(敏感度56%),假阴性12例。
  • Duke标准敏感度79%,联合FDG PET/CT后全部确诊IE患者敏感度89%。
  • PVE患者Duke标准敏感度78%,联合FDG PET/CT后敏感度94%。
  • 假阴性扫描患者中观察到更高的假体年龄。

关键数值与推荐

  • FDG PET/CT在手术证实IE队列中敏感度为56%。
  • Duke标准联合FDG PET/CT使全部确诊IE敏感度由79%升至89%。
  • Duke标准联合FDG PET/CT使PVE患者敏感度由78%升至94%,对应16%的诊断增益。

临床怎么用

  • 在疑似IE尤其是PVE患者中,可将FDG PET/CT与Duke标准联合以提高诊断敏感度。
  • 假体年龄较高的患者FDG PET/CT可能出现假阴性,判读时需结合临床。

局限性

  • 本研究为单中心回顾性分析,最终样本量29例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We assessed the diagnostic value of FDG PET/CT in a real-world cohort of patients with surgically managed infective endocarditis (IE). METHODS: We performed a retrospective analysis of all patients hospitalized in a tertiary IE referral medical center from January 2014 to October 2018 fulfilling the following criteria: ICD-10 code for IE and OPS code for both, heart surgery and FDG PET/CT. RESULTS: Final analysis included 29 patients, whereof 28 patients had surgically proven IE. FDG PET/CT scan was true-positive in 15 patients (sensitivity (SEN) 56%) and false-negative in 12 patients. Combination of Duke criteria (DC) with FDG PET/CT scan resulted in gain of SEN for all patients with confirmed IE (SEN of DC 79% vs SEN of combination DC and FDG PET/CT 89%), driven by a relevant gain in PVE patients only (SEN of DC 78% vs SEN of combination DC and FDG PET/CT 94%). Interestingly, higher prosthesis age was observed in patients with false-negative scans. CONCLUSIONS: We found a SEN of 56% for FDG PET/CT in a real-world cohort of patients with surgically proven IE which was associated with a 16% gain of IE diagnosis in patients with PVE when combined with DC.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Sag SJM, Menhart K, Grosse J, et al. Diagnostic value of FDG PET/CT imaging in patients with surgically managed infective endocarditis: results of a retrospective analysis at a tertiary center. J Nucl Cardiol. 2020. PMID: 33354758. doi:10.1007/s12350-020-02457-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。