文献速递骨显像与常规 SPECT肿瘤 PET/CT

MRI、[18F]FDG PET/CT与99mTc-UBI 29-41显像诊断术后脊柱感染的比较

Comparison of MRI, [18F]FDG PET/CT, and 99mTc-UBI 29-41 scintigraphy for postoperative spondylodiscitis-a prospective multicenter study.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2020-11-18

这项前瞻性多中心研究纳入63例疑似术后脊柱感染患者,评估MRI、[18F]FDG PET/CT和99mTc-UBI 29-41 SPECT/CT的诊断效能。MRI与[18F]FDG PET/CT诊断效能相当,AUC分别为0.78和0.80,两者联合AUC达0.938;99mTc-UBI 29-41 SPECT/CT敏感性44%或特异性41%,表现欠佳。

要点

  • MRI与[18F]FDG PET/CT诊断术后脊柱感染效能相当,联合应用最佳。
  • 99mTc-UBI 29-41 SPECT/CT在本研究术后场景中诊断效能不理想。
  • 发热、伤口渗液和CRP升高与术后脊柱感染显著相关。

核心结论

  • MRI与[18F]FDG PET/CT对疑似术后脊柱感染具有同等满意的诊断效能,两者联合诊断效能最佳。
  • 99mTc-UBI 29-41 SPECT/CT在本研究术后临床场景中诊断效能欠佳。

研究设计与样本

  • 前瞻性多中心研究,最终分析纳入63例疑似术后脊柱感染患者,其中15例完成全部3种影像,48例完成至少2种影像。
  • 最终诊断基于活检或至少6个月随访,影像由指定核心实验室专家盲法判读。
  • 63例中46例(73%)脊柱手术涉及金属植入物,30例(48%)诊断为术后脊柱感染。

主要发现

  • 感染与未感染组间发热(P=0.041)、伤口渗液(P<0.0001)和CRP升高(P=0.042)差异显著。
  • 是否涉及脊柱植入物手术的患者感染频率无差异。
  • MRI与[18F]FDG PET/CT的ROC曲线下面积分别为0.78(95%CI:0.64-0.92)和0.80(95%CI:0.64-0.98)。
  • 99mTc-UBI 29-41 SPECT/CT在较严格或较宽松判读标准下,敏感性44%或特异性41%,均不可接受。
  • MRI联合[18F]FDG PET/CT的ROC曲线下面积达0.938(95%CI:0.80-1.00)。

关键数值与推荐

  • MRI与[18F]FDG PET/CT诊断效能相当,AUC分别为0.78(95%CI:0.64-0.92)和0.80(95%CI:0.64-0.98)。
  • MRI联合[18F]FDG PET/CT的AUC为0.938(95%CI:0.80-1.00)。
  • 99mTc-UBI 29-41 SPECT/CT敏感性44%或特异性41%,表现欠佳。

临床怎么用

  • 对疑似术后脊柱感染患者,可优先考虑MRI或[18F]FDG PET/CT,两者联合可提高诊断效能。
  • 99mTc-UBI 29-41 SPECT/CT在该术后场景中不宜作为常规诊断手段。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Postoperative infection still constitutes an important complication of spine surgery, and the optimal imaging modality for diagnosing postoperative spine infection has not yet been established. The aim of this prospective multicenter study was to assess the diagnostic performance of three imaging modalities in patients with suspected postoperative spine infection: MRI, [18F]FDG PET/CT, and SPECT/CT with 99mTc-UBI 29-41. METHODS: Patients had to undergo at least 2 out of the 3 imaging modalities investigated. Sixty-three patients enrolled fulfilled such criteria and were included in the final analysis: 15 patients underwent all 3 imaging modalities, while 48 patients underwent at least 2 imaging modalities (MRI + PET/CT, MRI + SPECT/CT, or PET/CT + SPECT/CT). Final diagnosis of postoperative spinal infection was based either on biopsy or on follow-up for at least 6 months. The MRI, PET/CT, and SPECT/CT scans were read blindly by experts at designated core laboratories. Spine surgery included metallic implants in 46/63 patients (73%); postoperative spine infection was diagnosed in 30/63 patients (48%). RESULTS: Significant discriminants between infection and no infection included fever (P = 0.041), discharge at the wound site (P < 0.0001), and elevated CRP (P = 0.042). There was no difference in the frequency of infection between patients who underwent surgery involving spinal implants versus those who did not. The diagnostic performances of MRI and [18F]FDG PET/CT analyzed as independent groups were equivalent, with values of the area under the ROC curve equal to 0.78 (95% CI: 0.64-0.92) and 0.80 (95% CI: 0.64-0.98), respectively. SPECT/CT with 99mTc-UBI 29-41 yielded either unacceptably low sensitivity (44%) or unacceptably low specificity (41%) when adopting more or less stringent interpretation criteria. The best diagnostic performance was observed when combining the results of MRI with those of [18F]FDG PET/CT, with an area under the ROC curve equal to 0.938 (95% CI: 0.80-1.00). CONCLUSION: [18F]FDG PET/CT and MRI both possess equally satisfactory diagnostic performance in patients with suspected postoperative spine infection, the best diagnostic performance being obtained by combining MRI with [18F]FDG PET/CT. The diagnostic performance of SPECT/CT with 99mTc-UBI 29-41 was suboptimal in the postoperative clinical setting explored with the present study.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Paez D, Sathekge MM, Douis H, et al. Comparison of MRI, [18F]FDG PET/CT, and 99mTc-UBI 29-41 scintigraphy for postoperative spondylodiscitis-a prospective multicenter study. Eur J Nucl Med Mol Imaging. 2020. PMID: 33210240. doi:10.1007/s00259-020-05109-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。