文献速递心脏核医学

18F-氟化钠PET与99mTc-焦磷酸盐显像在心脏淀粉样变性中的比较

Comparison of 18F-sodium fluoride positron emission tomography imaging and 99mTc-pyrophosphate in cardiac amyloidosis.
PubMed 文献 · J Nucl Cardiol · 2020-11-04

视觉判读NaF PET/CT灵敏度仅0.25(95%CI 0.089-0.53),显著低于PYP-SPECT/CT的100%(P=.016),定量分析亦无显著鉴别能力。

要点

  • NaF PET/CT视觉判读诊断ATTR-CA灵敏度显著低于PYP-SPECT/CT。
  • NaF PET定量TBRmean在患者与对照间无显著差异,ROC曲线下面积仅0.69。
  • 研究未发现NaF PET假阳性,但灵敏度不足限制其作为首选诊断工具。

核心结论

  • 视觉和定量分析均显示NaF PET/CT诊断ATTR-CA的灵敏度显著低于PYP-SPECT。

主要发现

  • NaF PET/CT视觉判读灵敏度为0.25(95%CI 0.089-0.53),PYP-SPECT/CT为100%(P=.016)。
  • 3小时视觉判读灵敏度为0.30(95%CI 0.11-0.60,P=1.00)。
  • 1小时TBRmean在ATTR-CA组为0.83±0.15,对照组为0.72±0.15,差异无统计学意义(P=.21)。
  • ROC分析AUC为0.69±0.16(95%CI 0.37-1.00,P=.23)。
  • 未见NaF PET假阳性研究。

临床怎么用

  • 对于疑诊ATTR-CA的患者,PYP-SPECT仍是灵敏度更高的分子影像诊断方法。
  • NaF PET/CT目前不推荐替代PYP显像用于ATTR-CA的诊断。

局限性

  • 单中心前瞻性设计可能限制普遍性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Pyrophosphate (PYP) scintigraphy provides high diagnostic accuracy for the detection of transthyretin (ATTR) cardiac amyloidosis (CA). There has recently been emerging interest in using 18F-sodium fluoride (NaF) for this application, yet its sensitivity has never been directly compared to that of PYP, the current molecular gold standard METHODS: Twelve subjects with ATTR-CA and 5 controls referred for PYP-SPECT were prospectively enrolled. 18F-NaF PET/CT scans were performed at 1 and 3 hours. Qualitative and quantitative analyses of the images were performed, and the sensitivity of 18F-NaF PET/CT and PYP-SPECT were compared RESULTS: Visual interpretation of NaF PET/CT yielded a sensitivity of 0.25 (95% CI 0.089 to 0.53) for the detection of ATTR-CA, which is significantly inferior to that of PYP-SPECT/CT (100%, P = .016). Visual interpretation at 3 hours yielded a similar sensitivity of 0.30 (95% CI 0.11 to 0.60, P = 1.00). There were no false-positive NaF PET studies. Mean target-to-background ratio (TBRmean) at 1h did not differ significantly (P = .21) in ATTR-CA subjects (0.83 ± 0.15) compared to controls (0.72 ± 0.15). Receiver operating characteristic (ROC) analysis yielded an area under the curve (AUC) of 0.69 ± 0.16 (95% CI 0.37 to 1.00, P = .23). CONCLUSION: With qualitative and quantitative analyses, sensitivity of NaF PET/CT is significantly inferior to that of PYP-SPECT for the diagnosis of ATTR-CA.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。