文献速递神经核医学肿瘤 PET/CT

[11C]PIB淀粉样蛋白定量:参考区域选择的影响

[11C]PIB amyloid quantification: effect of reference region selection.
PubMed 文献 · EJNMMI Res · 2020-10-19

以GMCB为参考区域的血浆输入法(2T4k_Vb)为金标准,评估重测变异性、与金标准的相关性和一致性、纵向稳定性及判别Aβ阳性/阴性扫描的能力。结论认为GMCB和WCB是[11C]PiB PET定量淀粉样蛋白负荷的最佳参考区域。

要点

  • 所有参考区域重测变异性稳定(最大5.1%),WCB变异性持续较低。
  • 所有方法均可判别Aβ阳性与阴性扫描,GMCB效应量最高(-0.9至-0.7),WCB次之(-0.8至-0.6)。
  • GMCB和WCB被认为是[11C]PiB PET定量淀粉样蛋白负荷的最佳参考区域。

核心结论

  • GMCB和WCB被认为是使用[11C]PiB PET定量淀粉样蛋白负荷的最佳参考区域。

研究设计与样本

  • 回顾性纳入来自重测研究的13例受试者和来自纵向研究的30例受试者(总计17例阿尔茨海默病、13例轻度认知障碍、13例对照)。
  • 采集动态[11C]PiB PET(90分钟)和T1加权MR扫描,共配准后提取皮层靶区域和五种参考区域的时间-活动曲线。
  • 以GMCB为参考区域的两组织可逆血浆输入模型(2T4k_Vb)为金标准,并计算参考Logan和简化参考组织模型得出的分布体积比(DVR),以及40-60分钟和60-90分钟区间的标准化摄取值比(SUV ratio)。
  • 利用重测扫描评估参数变异性,并评估与金标准(GMCB参考区域的2T4k_Vb DVR)的相关性和一致性。
  • 评估各参考区域SUV在纵向随访中的变化,并评估判别视觉Aβ阳性与阴性扫描的能力。

主要发现

  • 所有参考区域均表现出稳定的重测性能(最大变异性5.1%),WCB持续显示较低的变异性。
  • 所有方法均能判别Aβ阳性与阴性扫描,GMCB效应量最高(范围-0.9至-0.7),WCB次之(范围-0.8至-0.6)。
  • 所有方法与金标准均具有良好的相关性(r ≥ 0.78),WMES的偏倚最大(回归斜率范围0.52-0.67),其次为WBS(斜率范围0.58-0.92)和WMBS(斜率范围0.62-0.91)。
  • 除WBS和WMBS参考区域(60-90分钟区间)外,所有参考区域SUV在2.6年期间保持稳定。

关键数值与推荐

  • 重测变异性最大为5.1%。
  • 与金标准的相关性r ≥ 0.78。
  • WMES回归斜率范围0.52-0.67,WBS范围0.58-0.92,WMBS范围0.62-0.91。
  • GMCB效应量范围-0.9至-0.7,WCB范围-0.8至-0.6。

临床怎么用

  • 在[11C]PiB PET淀粉样蛋白定量中,优先选择GMCB或WCB作为参考区域。
  • WCB重测变异性较低,可作为稳定的参考区域选择。
  • 避免使用WMES、WBS和WMBS作为参考区域,因其偏倚较大或纵向稳定性不足。

局限性

  • 金标准基于GMCB参考区域的血浆输入模型,未采用独立绝对定量标准。
  • 纵向稳定性评估仅覆盖2.6年随访期。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The standard reference region (RR) for amyloid-beta (Aβ) PET studies is the cerebellar grey matter (GMCB), while alternative RRs have mostly been utilized without prior validation against the gold standard. This study compared five commonly used RRs to gold standard plasma input-based quantification using the GMCB. METHODS: Thirteen subjects from a test-retest (TRT) study and 30 from a longitudinal study were retrospectively included (total: 17 Alzheimer's disease, 13 mild cognitive impairment, 13 controls). Dynamic [11C]PiB PET (90 min) and T1-weighted MR scans were co-registered and time-activity curves were extracted for cortical target regions and the following RRs: GMCB, whole cerebellum (WCB), white matter brainstem/pons (WMBS), whole brainstem (WBS) and eroded subcortical white matter (WMES). A two-tissue reversible plasma input model (2T4k_Vb) with GMCB as RR, reference Logan and the simplified reference tissue model were used to derive distribution volume ratios (DVRs), and standardized uptake value (SUV) ratios were calculated for 40-60 min and 60-90 min intervals. Parameter variability was evaluated using TRT scans, and correlations and agreements with the gold standard (DVR from 2T4k_Vb with GMCB RR) were also assessed. Next, longitudinal changes in SUVs (both intervals) were assessed for each RR. Finally, the ability to discriminate between visually Aβ positive and Aβ negative scans was assessed. RESULTS: All RRs yielded stable TRT performance (max 5.1% variability), with WCB consistently showing lower variability. All approaches were able to discriminate between Aβ positive and Aβ negative scans, with highest effect sizes obtained for GMCB (range - 0.9 to - 0.7), followed by WCB (range - 0.8 to - 0.6). Furthermore, all approaches provided good correlations with the gold standard (r ≥ 0.78), while the highest bias (as assessed by the regression slope) was observed using WMES (range slope 0.52-0.67), followed by WBS (range slope 0.58-0.92) and WMBS (range slope 0.62-0.91). Finally, RR SUVs were stable across a period of 2.6 years for all except WBS and WMBS RRs (60-90 min interval). CONCLUSIONS: GMCB and WCB are considered the best RRs for quantifying amyloid burden using [11C]PiB PET.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Heeman F, Hendriks J, Lopes Alves I, et al. [11C]PIB amyloid quantification: effect of reference region selection. EJNMMI Res. 2020. PMID: 33074395. doi:10.1186/s13550-020-00714-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。