门控心肌灌注SPECT相位分析评估左室功能与收缩不同步参数的多中心可重复性研究
该研究为前瞻性多中心队列的事后分析,比较10个临床中心与核心实验室对276例门控心肌灌注SPECT(GMPS)左室功能及相位分析参数的一致性。除左室相位标准差(LVPSD)外各变量无显著差异,排除无机械不同步者后LVPSD差异亦不显著。LVESV、LVEF、LVPSD及PLVNV与核心实验室强相关且Bland-Altman一致性良好。
要点
- 多中心与核心实验室的LV功能及相位分析参数相关性好、一致性佳。
- 仅LVPSD存在显著差异,排除无机械不同步者后差异消失。
- 结果支持GMPS相位分析在临床心衰管理中的可重复性。
核心结论
- 不同临床中心与核心实验室的GMPS左室功能及不同步分析相关性和一致性良好,支持GMPS在心衰临床管理中的可靠性。
研究设计与样本
- 前瞻性、非随机、多国多中心队列研究的事后分析,纳入276例在CRT前(基线)及CRT后6个月(随访)完成临床评估和GMPS的检查。
- 由10个中心获取LVESV、LVEDV、LVEF、LVPSD和PLVNV,并与核心实验室结果进行比较。
主要发现
- 除LVPSD外,各中心与核心实验室之间所有变量均无统计学显著差异。
- 排除无机械不同步的受试者后,LVPSD差异变为不显著。
- LVESV、LVEF、LVPSD和PLVNV在中心与核心实验室比较中呈强相关。
- Bland-Altman图显示良好一致性。
临床怎么用
- GMPS相位分析获得的左室功能与不同步参数在不同临床中心间可重复,可用于心衰患者的临床管理。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Gated myocardial perfusion scintigraphy (GMPS) phase analysis is an important tool to investigate the physiology of left ventricular (LV) dyssynchrony. We aimed to test the performance of GMPS LV function and phase analysis in different clinical settings and on a diverse population. METHODS: This is a post hoc analysis of a prospective, non-randomized, multinational, multicenter cohort study. Clinical evaluation and GMPS prior to cardiac resynchronization therapy (CRT)(baseline) and 6-month post CRT (follow-up) were done. LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV), LV ejection fraction (LVEF), LV phase standard deviation (LVPSD), and percentage of left ventricle non-viable (PLVNV) were obtained by 10 centers and compared to the core lab. RESULTS: 276 GMPS studies had all data available from individual sites and from core lab. There were no statistically significant differences between all variables except for LVPSD. When subjects with no mechanical dyssynchrony were excluded, LVPSD difference became non-significant. LVESV, LVEF, LVPSD and PLVNV had strong correlation in site against core lab comparison. Bland-Altman plots demonstrated good agreement. CONCLUSIONS: The presented correlation and agreement of LV function and dyssynchrony analysis over different sites with a diverse sample corroborate the strength of GMPS in the management of heart failure in clinical practice.
引用
- de Amorim Fernandes F, Peix A, Giubbini R, et al. Reproducibility of global LV function and dyssynchrony parameters derived from phase analysis of gated myocardial perfusion SPECT: A multicenter comparison with core laboratory setting. J Nucl Cardiol. 2020. PMID: 33083983. doi:10.1007/s12350-020-02397-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。