左束支传导阻滞或心室起搏节律患者中SPECT与PET心肌灌注显像的诊断准确性
本研究比较了血管扩张剂负荷SPECT与PET心肌灌注显像在左束支传导阻滞(LBBB)或心室起搏节律(VPR)患者中检测阻塞性冠状动脉疾病(CAD)的诊断准确性。55例患者接受冠状动脉造影,其中38例(69%)行SPECT、17例(31%)行PET。
要点
- SPECT中LBBB/VPR相关室间隔缺损(72% vs 17%)和室间隔前壁缺损(47% vs 8%)更常见。
- PET的敏感性和特异性均优于SPECT(88% vs 60%;56% vs 14%)。
核心结论
- 在LBBB或VPR患者中,PET心肌灌注显像检测阻塞性CAD的诊断准确性高于SPECT。
研究设计与样本
- 回顾性识别接受血管扩张剂负荷SPECT或PET心肌灌注显像并随后行冠状动脉造影的LBBB或VPR患者,共55例,其中SPECT 38例(69%)、PET 17例(31%)。
主要发现
- PET较SPECT检测阻塞性CAD的敏感性为88% vs 60%,特异性56% vs 14%,阳性预测值64% vs 20%,阴性预测值83% vs 50%。
关键数值与推荐
- LBBB/VPR相关室间隔和室间隔前壁缺损定义为在左前降支或左主干无阻塞性CAD时累及这些区域的灌注缺损。
临床怎么用
- 对于LBBB或VPR患者,选择PET心肌灌注显像可能比SPECT提供更高的阻塞性CAD诊断准确性。
局限性
- 样本量较小(共55例,PET仅17例),可能影响结果的稳健性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The difference in diagnostic accuracy of coronary artery disease (CAD) between vasodilator SPECT and PET myocardial perfusion imaging (MPI) in patients with left bundle branch block (LBBB) or ventricular-paced rhythm (VPR) is unknown. METHODS: We identified patients with LBBB or VPR who underwent either vasodilator SPECT or PET MPI and subsequent coronary angiography. LBBB/VPR-related septal and anteroseptal defects were defined as perfusion defects involving those regions in the absence of obstructive CAD in the left anterior descending artery or left main coronary artery. RESULTS: Of the 55 patients who underwent coronary angiography, 38 (69%) underwent SPECT and 17 patients (31%) underwent PET. PET compared to SPECT demonstrated higher sensitivity (88% vs 60%), specificity (56% vs 14%), positive predictive value (64% vs 20%), negative predictive value (83% vs 50%), and overall superior diagnostic accuracy (AUC .72 (95% CI .50-.93) vs .37 (95% CI .20-.54), P = .01) to detect obstructive CAD. LBBB/VPR-related septal and anteroseptal defects were more common with SPECT compared to PET (septal: 72% vs 17%, P = .001; anteroseptal: 47% vs 8%, P = .02). CONCLUSIONS: PET has higher diagnostic accuracy when compared to SPECT for the detection of obstructive CAD in patients with LBBB or VPR.
引用
- Vidula MK, Wiener P, Selvaraj S, et al. Diagnostic accuracy of SPECT and PET myocardial perfusion imaging in patients with left bundle branch block or ventricular-paced rhythm. J Nucl Cardiol. 2020. PMID: 33083984. doi:10.1007/s12350-020-02398-5