三维卷积神经网络自动分割弥漫大B细胞淋巴瘤病灶预测总代谢肿瘤体积
本研究基于733例弥漫大B细胞淋巴瘤患者治疗前FDG-PET/CT,训练三维U-net卷积神经网络自动分割病灶并预测总代谢肿瘤体积(TMTV)。外部验证集平均Dice系数0.73±0.20、Jaccard系数0.68±0.21,TMTV平均低估116 mL(20.8%)±425(P=0.01)。该网络有望用于淋巴瘤病灶自动检测与分割,但TMTV存在轻度低估。
要点
- 三维CNN自动分割淋巴瘤病灶的Dice系数为0.73±0.20,Jaccard系数0.68±0.21。
- 外部验证集TMTV平均低估116 mL(20.8%)±425,差异有统计学意义(P=0.01)。
- 该CNN开源且全自动,有望提高TMTV评估的可重复性并推广至常规实践。
核心结论
- 该CNN是自动检测和分割淋巴瘤病灶的有前景工具,尽管TMTV存在轻度低估。
研究设计与样本
- 数据集包含2项LYSA前瞻性试验中733例DLBCL患者治疗前的FDG-PET/CT。
- 第一队列(n=639)采用5折交叉验证方案用于训练。
- 第二队列(n=94)用于TMTV预测的外部验证。
- 参考标准掩膜通过淋巴瘤病灶41% SUVmax自适应阈值化后手动获得。
- 采用3D U-net架构,PET和CT双输入通道,在随机采样的PET/CT patch上以summed cross entropy和Dice相似系数(DSC)损失训练。
主要发现
- 验证集平均DSC和Jaccard系数(±标准差)分别为0.73±0.20和0.68±0.21。
- 第一队列验证集TMTV平均低估-12 mL(2.8%)±263(P=0.27)。
- 第二队列TMTV平均低估-116 mL(20.8%)±425,差异有统计学意义(P=0.01)。
关键数值与推荐
- 分割性能以DSC和Jaccard系数评估。
- 参考标准掩膜基于淋巴瘤病灶41% SUVmax自适应阈值化手动获得。
临床怎么用
- 该CNN可全自动检测和分割淋巴瘤病灶并预测TMTV,开源特性有助于在常规实践中推广和提升TMTV评估可重复性。
局限性
- 外部验证集TMTV平均低估20.8%且差异有统计学意义(P=0.01)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Lymphoma lesion detection and segmentation on whole-body FDG-PET/CT are a challenging task because of the diversity of involved nodes, organs or physiological uptakes. We sought to investigate the performances of a three-dimensional (3D) convolutional neural network (CNN) to automatically segment total metabolic tumour volume (TMTV) in large datasets of patients with diffuse large B cell lymphoma (DLBCL). METHODS: The dataset contained pre-therapy FDG-PET/CT from 733 DLBCL patients of 2 prospective LYmphoma Study Association (LYSA) trials. The first cohort (n = 639) was used for training using a 5-fold cross validation scheme. The second cohort (n = 94) was used for external validation of TMTV predictions. Ground truth masks were manually obtained after a 41% SUVmax adaptive thresholding of lymphoma lesions. A 3D U-net architecture with 2 input channels for PET and CT was trained on patches randomly sampled within PET/CTs with a summed cross entropy and Dice similarity coefficient (DSC) loss. Segmentation performance was assessed by the DSC and Jaccard coefficients. Finally, TMTV predictions were validated on the second independent cohort. RESULTS: Mean DSC and Jaccard coefficients (± standard deviation) in the validations set were 0.73 ± 0.20 and 0.68 ± 0.21, respectively. An underestimation of mean TMTV by - 12 mL (2.8%) ± 263 was found in the validation sets of the first cohort (P = 0.27). In the second cohort, an underestimation of mean TMTV by - 116 mL (20.8%) ± 425 was statistically significant (P = 0.01). CONCLUSION: Our CNN is a promising tool for automatic detection and segmentation of lymphoma lesions, despite slight underestimation of TMTV. The fully automatic and open-source features of this CNN will allow to increase both dissemination in routine practice and reproducibility of TMTV assessment in lymphoma patients.
引用
- Blanc-Durand P, Jégou S, Kanoun S, et al. Fully automatic segmentation of diffuse large B cell lymphoma lesions on 3D FDG-PET/CT for total metabolic tumour volume prediction using a convolutional neural network. Eur J Nucl Med Mol Imaging. 2020. PMID: 33097974. doi:10.1007/s00259-020-05080-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。