动态双示踪剂[13N]NH3与[18F]FDG PET/MRI评估左右心室功能参数

Assessment of left and right ventricular functional parameters using dynamic dual-tracer [13N]NH3 and [18F]FDG PET/MRI.
PubMed 文献 · J Nucl Cardiol · 2020-10-22

研究在22例冠心病患者中,个体内比较动态[13N]NH3和[18F]FDG PET/MRI扫描获得的右心室(RV)和左心室(LV)功能参数,并以MRI为参考。结果显示从动态NH3和FDG PET各时相推导LV和RV功能值可行,且与MRI有中至强相关及良好一致性。

要点

  • 动态双示踪剂PET/MRI可评估左右心室功能参数,与MRI相关性中至强。
  • FDG和NH3的首过射血分数与MRI的相关性分别为R=.51和R=.64。
  • 早期16门控及晚期时相获得的LV参数与MRI多呈强相关(R>.7)。

核心结论

  • 从动态NH3和FDG PET各时相推导LV和RV功能值是可行的。
  • 这些结果可能为PET检查的进一步临床应用开辟新视角。

研究设计与样本

  • 在22例冠心病患者(69±9岁)中,个体内采集动态[13N]NH3和[18F]FDG PET扫描,并以MRI为参考。

主要发现

  • FDG和NH3的RVFPEF分别为28±11%和32±11%,LVFPEF分别为32±15%和41±14%;MRI的RVEF和LVEF分别为42±16%和45±19%。
  • 早期FDG和NH3在8门控的LVESV、LVEDV、LVEF分别为71(15至213 mL)、98(16至241 mL)、32±17%和50(17至206 mL)、93(13至219 mL)、36±17%。
  • 早期FDG和NH3在16门控的LVESV、LVEDV、LVEF分别为60(19至360 mL)、109(56至384 mL)、41±22%和54(16至371 mL)、116(57至431 mL)、46±24%。
  • 晚期FDG和NH3的LVESV、LVEDV、LVEF分别为85±63 mL、138±63 mL、47±19%和79±56 mL、137±63 mL、47±20%;MRI的LVESV、LVEDV分别为93±66 mL和153±71 mL。
  • FDG与MRI的RVFPEF和LVFPEF相关性分别为R=.51(P=.01)和R=.64(P=.001);早期16门控及晚期FDG和NH3的LV参数与MRI多呈R>.7(P=.000或P<.001),但NH3的EDV与MRI的EDV相关性较弱(R=.54,P<.05);Bland-Altman图一般显示PET与MRI agreement良好。

临床怎么用

  • 可利用动态双示踪剂PET/MRI扫描的各时相推导左右心室功能参数,作为MRI的补充评估手段。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Cardiac positron emission tomography/magnetic resonance imaging (PET/MRI) can assess various cardiovascular diseases. In this study, we intra-individually compared right (RV) and left ventricular (LV) parameters obtained from dual-tracer PET/MRI scan. METHODS: In 22 patients with coronary heart disease (69 ± 9 years) dynamic [13N]NH3 (NH3) and [18F]FDG (FDG) PET scans were acquired. The first 2 minutes were used to calculate LV and RV first-pass ejection fraction (FPEF). Additionally, LV end-systolic (LVESV) and end-diastolic (LVEDV) volume and ejection fraction (LVEF) were calculated from the early (EP) and late-myocardial phases (LP). MRI served as a reference. RESULTS: RVFPEF and LVFPEF from FDG and NH3 as well as RVEF and LVEF from MRI were (28 ± 11%, 32 ± 15%), (32 ± 11%, 41 ± 14%) and (42 ± 16%, 45 ± 19%), respectively. LVESV, LVEDV and LVEF from EP FDG and NH3 in 8 and 16 gates were [71 (15 to 213 mL), 98 (16 to 241 mL), 32 ± 17%] and [50 (17 to 206 mL), 93 (13 to 219 mL), 36 ± 17%] as well as [60 (19 to 360 mL), 109 (56 to 384 mL), 41 ± 22%] and [54 (16 to 371 mL), 116 (57 to 431 mL), 46 ± 24%], respectively. Moreover, LVESV, LVEDV and LVEF acquired from LP FDG and NH3 were (85 ± 63 mL, 138 ± 63 mL, 47 ± 19%) and (79 ± 56 mL, 137 ± 63 mL, 47 ± 20%), respectively. The LVESV, LVEDV from MRI were 93 ± 66 mL and 153 ± 71 mL, respectively. Significant correlations were observed for RVFPEF and LVFPEF between FDG and MRI (R = .51, P = .01; R = .64, P = .001), respectively. LVESV, LVEDV, and LVEF revealed moderate to strong correlations to MRI when they acquired from EP FDG and NH3 in 16 gates (all R > .7, P = .000). Similarly, all LV parameters from LP FDG and NH3 correlated good to strongly positive with MRI (all R > .7, and P < .001), except EDV from NH3 weakly correlated to EDV of MRI (R = .54, P < .05). Generally, Bland-Altman plots showed good agreements between PET and MRI. CONCLUSIONS: Deriving LV and RV functional values from various phases of dynamic NH3 and FDG PET is feasible. These results could open a new perspective for further clinical applications of the PET examinations.