融合18F-FDG PET/心脏磁共振成像在心脏结节病中的诊断价值
本研究纳入74例疑似心脏结节病(CS)患者,比较单独FDG PET与融合PET/CMR区域分析的诊断效能。融合PET/CMR的诊断一致性(κ=0.89)和总体准确率(87.8%)均优于单独PET(κ=0.57,准确率82.4%),在弥漫性及弥漫背景下局灶性摄取模式亚组中仍具优势。
要点
- 融合PET/CMR区域分析诊断CS的观察者间一致性κ=0.89,总体准确率87.8%。
- 单独PET诊断CS的一致性κ=0.57,总体准确率82.4%,均低于融合影像。
- 在弥漫及弥漫背景下局灶性摄取模式亚组中,融合PET/CMR一致性κ=0.86、准确率81.8%。
核心结论
- 融合PET/CMR区域分析可提供可靠且准确的CS诊断,弥补单独FDG-PET的低诊断区域。
研究设计与样本
- 研究纳入74例疑似心脏结节病患者,以AHA 17节段模型进行区域分析。
- 单独PET诊断活动性CS定义为局灶性或弥漫背景下局灶性FDG摄取模式。
- 融合PET/CMR将患者分为PET-/LGE-、PET+/LGE-、PET+/LGE+、PET-/LGE+四组,PET+/LGE+定义为活动性CS。
主要发现
- 单独PET与融合PET/CMR之间20例对活动性CS的评估不一致,多数在单独PET上表现为弥漫性或弥漫背景下局灶性FDG摄取模式。
- 40例患者符合2016年日本循环学会CS诊断标准。
- 融合PET/CMR的观察者间诊断一致性κ=0.89,总体准确率87.8%;单独PET分别为κ=0.57和82.4%。
- 在弥漫及弥漫背景下局灶性模式亚组中,融合PET/CMR一致性κ=0.86、准确率81.8%,仍优于单独PET。
临床怎么用
- 对疑似心脏结节病患者,可采用融合PET/CMR区域分析提高诊断准确性与观察者间一致性。
- 对于单独PET表现为弥漫性或弥漫背景下局灶性FDG摄取模式者,融合PET/CMR有助于减少误诊。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although each 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) and cardiac magnetic resonance (CMR) imaging with late gadolinium enhancement (LGE) has been used to diagnose cardiac sarcoidosis (CS), active CS is still misdiagnosed. METHODS: Active CS, diagnosed by PET alone, was defined as focal or focal on diffuse FDG uptake pattern. In fusion PET/CMR imaging, using a regional analysis with AHA 17-segment model, the patients were categorized into four groups: (1) PET-/LGE-, (2) PET+/LGE-, (3) PET+/LGE+, and (4) PET-/LGE+. PET+/LGE+ was defined as active CS. RESULTS: 74 Patients with suspected CS were enrolled. Between PET alone and fusion PET/CMR imaging, 20 cases had mismatch evaluations of active CS, and most had diffuse or focal on diffuse FDG uptake pattern on PET alone imaging. 40 Patients fulfilled the 2016 the Japanese Circulation Society diagnostic criteria for CS. The interobserver diagnostic agreement was excellent (κ statistics 0.89) and the overall accuracy for diagnosing CS was 87.8% in fusion PET/CMR imaging, which were superior to those in PET alone imaging (0.57 and 82.4%, respectively). In a sub-analysis of diffuse and focal on diffuse patterns, the agreement (κ statistics 0.86) and overall accuracy (81.8%) in fusion PET/CMR imaging were still better. CONCLUSIONS: Fusion PET/CMR imaging with regional analysis offered reliable and accurate diagnosis of CS, covering low diagnostic area by FDG-PET alone.
引用
- Okune M, Yasuda M, Soejima N, et al. Diagnostic utility of fusion 18F-fluorodeoxyglucose positron emission tomography/cardiac magnetic resonance imaging in cardiac sarcoidosis. J Nucl Cardiol. 2020. PMID: 33000410. doi:10.1007/s12350-020-02359-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。