宫颈癌18F-FDG PET影像组学特征的可重复性
本研究评估宫颈肿瘤18F-FDG PET影像组学特征的重测可重复性,并探索图像预处理方法的影响。形状、邻域灰度差矩阵和灰度共生矩阵特征可重复(平均CCC 0.81),PETOSEM图像特征优于PETPSF(P<0.001),VOI40特征优于VOIWT(P<0.001)。
要点
- 形状、邻域灰度差矩阵和灰度共生矩阵特征可重复性较好(平均CCC 0.81)。
- PETOSEM重建图像提取的特征可重复性显著优于PETPSF(P<0.001)。
- VOI40提取的特征可重复性显著优于VOIWT(P<0.001)。
核心结论
- 形状、灰度共生矩阵和邻域灰度差矩阵影像组学特征具有一致的可重复性。
- 灰度游程长度矩阵和灰度区域长度矩阵特征变异性高。
- VOI40提取的特征比VOIWT提取的特征更可重复。
研究设计与样本
- PET图像采用PETOSEM或PETPSF两种方法重建。
- 肿瘤分割为全肿瘤感兴趣体积(VOIWT)和40%等轮廓(VOI40)。
- 体素保持默认大小或重采样为3-mm各向同性体素,SUV离散化为32、64或128个固定箱数。
- 采用Lin一致性相关系数(CCC)评估重测可重复性。
主要发现
- 形状、邻域灰度差矩阵和灰度共生矩阵特征可重复,平均CCC值为0.81。
- PETOSEM图像提取的影像组学特征可重复性显著优于PETPSF图像(P<0.001)。
- VOI40提取的影像组学特征可重复性显著优于VOIWT提取的特征(P<0.001)。
- 对于大多数特征(78.4%),箱数或体素大小变化导致特征值变化小于10%。
- 从VOIWT提取时所有灰度强调和灰度游程强调特征可重复性差(CCC<0.52),但从VOI40提取时高度可重复(平均CCC>0.96)。
关键数值与推荐
- 可重复特征的平均CCC值为0.81。
- PETOSEM与PETPSF图像特征可重复性比较的P<0.001。
- VOI40与VOIWT特征可重复性比较的P<0.001。
- 78.4%的特征在箱数或体素大小变化时特征值变化小于10%。
- VOIWT提取的灰度强调和灰度游程强调特征CCC值<0.52,VOI40提取时平均CCC值>0.96。
临床怎么用
- 在纵向解读宫颈癌18F-FDG PET影像组学特征变化时,应优先选择形状、灰度共生矩阵和邻域灰度差矩阵特征。
- 建议采用PETOSEM重建和VOI40分割以提高特征可重复性。
- 需注意灰度游程长度矩阵和灰度区域长度矩阵特征变异性高,不宜单独用于纵向比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Knowledge of the intrinsic variability of radiomic features is essential to the proper interpretation of changes in these features over time. The primary aim of this study was to assess the test-retest repeatability of radiomic features extracted from 18F-FDG PET images of cervical tumors. The impact of different image preprocessing methods was also explored. Methods: Patients with cervical cancer underwent baseline and repeat 18F-FDG PET/CT imaging within 7 d. PET images were reconstructed using 2 methods: ordered-subset expectation maximization (PETOSEM) or ordered-subset expectation maximization with point-spread function (PETPSF). Tumors were segmented to produce whole-tumor volumes of interest (VOIWT) and 40% isocontours (VOI40). Voxels were either left at the default size or resampled to 3-mm isotropic voxels. SUV was discretized to a fixed number of bins (32, 64, or 128). Radiomic features were extracted from both VOIs, and repeatability was then assessed using the Lin concordance correlation coefficient (CCC). Results: Eleven patients were enrolled and completed the test-retest PET/CT imaging protocol. Shape, neighborhood gray-level difference matrix, and gray-level cooccurrence matrix features were repeatable, with a mean CCC value of 0.81. Radiomic features extracted from PETOSEM images showed significantly better repeatability than features extracted from PETPSF images (P < 0.001). Radiomic features extracted from VOI40 were more repeatable than features extracted from VOIWT (P < 0.001). For most features (78.4%), a change in bin number or voxel size resulted in less than a 10% change in feature value. All gray-level emphasis and gray-level run emphasis features showed poor repeatability (CCC values < 0.52) when extracted from VOIWT but were highly repeatable (mean CCC values > 0.96) when extracted from VOI40Conclusion: Shape, gray-level cooccurrence matrix, and neighborhood gray-level difference matrix radiomic features were consistently repeatable, whereas gray-level run length matrix and gray-level zone length matrix features were highly variable. Radiomic features extracted from VOI40 were more repeatable than features extracted from VOIWT Changes in voxel size or SUV discretization parameters typically resulted in relatively small differences in feature value, though several features were highly sensitive to these changes.
引用
- Crandall JP, Fraum TJ, Lee M, et al. Repeatability of 18F-FDG PET Radiomic Features in Cervical Cancer. J Nucl Med. 2020. PMID: 33008931. doi:10.2967/jnumed.120.247999
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。